Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/13806
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPinos Neira, Rosa Elena-
dc.contributor.authorBuenaño Pico, Jennifer Jannina-
dc.date.accessioned2020-02-17T19:04:24Z-
dc.date.available2020-02-17T19:04:24Z-
dc.date.issued2019-12-17-
dc.identifier.citationBuenaño Pico, Jennifer Jannina. (2019). Diseño de un sistema de tratamiento de aguas residuales para la curtiduría San Isidro de la ciudad de Ambato. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13806-
dc.descriptionEl objetivo del presente trabajo de titulación es diseño de un sistema de tratamiento de aguas residuales para la curtiduría “San Isidro”, se inició con la caracterización de muestras de afluente de pelambre y curtido encontrándose los parámetros de DQO, DBO5, sulfuros, sulfatos, pH, sólidos totales y sedimentables para pelambre, cromo hexavalente, cromo total, pH, DQO, DBO5, sólidos totales y suspendidos para curtido superan el límite máximo permisible que rige el TULSMA, Libro VI, Anexo I, Tabla 8. Para elegir el tratamiento más idóneo se determinó el índice biodegradabilidad para pelambre dio el valor de 0,72 y para curtido de 0,38 definiendo un tratamiento biológico y/o físico-químico y físico-químico respectivamente, para ello se realizó aireación durante 6 h con adición de sulfato de manganeso al 5% a una concentración de 300 ppm con el fin de oxidar sulfuros, coagulación con PAC al 2% a 70 ppm y floculante catiónico a 10ppm y sedimentación por 2 h para pelambre mientras que el agua de curtido se sometió a precipitación con cal P-24, coagulación con PAC al 2% a 40 ppm y floculante aniónico a 2 ppm y sedimentación permitiendo clarificar el agua, la eficiencia de los ensayos se verificó caracterizando el agua tratada en el que se obtuvo que la mayoría de los parámetros estaban dentro de norma, DQO y DBO5 para los dos casos y sulfuros no entraban dentro de norma sin embargo hubo buen porcentaje de remoción. El sistema consta de: dos canales de entrada, tanque de aireación y homogenización, sedimentador, filtros de flujo ascendente y tanque de almacenamiento para agua tratada. Se recomienda recircular el agua para alimentar a los fulones de curtido y pelambre, el cual permitirá optimizar este recurso hídrico.es_ES
dc.description.abstractThe objective of this degree work is to design a tannery wastewater treatment system for the "San Isidro" facility, it was initiated with the characterization of tanning and liming effluent samples, finding the parameters of COD (Chemical Oxygen Demand), BOD5 (Biochemical Oxygen Demand), sulfides, sulfates, pH, total and sedimentary solids for liming process, hexavalent chromium, total chromium, pH, COD (Chemical Oxygen Demand), BOD5 (Biochemical Oxygen Demand), total and suspended solids for tanning exceed the maximum permissible limit that are demanded in TULSMA, Book VI, Annex I, Table 8. In order to choose the most suitable treatment, the biodegradability index was determined for liming which gave the value of 0.72 and for tanning 0.38 defining a Biological and / or physical-chemical and physical-chemical treatment respectively, for this aeration was performed over 6 h with the addition of 5% manganese sulfate at a concentration of 300 ppm in order to be able to oxidize sulfides, coagulation with PAC (Poly Aluminum chloride) at 2% at 70 ppm and cationic flocculant at 10ppm, sedimentation by 2 h and filtration with granular media for liming while the tanning water was subjected to precipitation with lime P- 24, coagulation with PAC (Poly Aluminum chloride) at 2% at 40 ppm and anionic flocculant at 2 ppm, sedimentation and filtration allowing clarification of the water, the efficiency of the tests was verified by characterizing the treated water in which it was obtained that most of the parameters were within the established standard, COD (Chemical Oxygen Demand) and BOD5 (Biochemical Oxygen Demand) for both cases and sulfides did not fall within the regulation standards, however there was a good percentage of removal. The system consists of: two inlet channels, aeration and homogenization tank, sedimentation tank, upflow filters and storage tank for treated water. It is recommended to recirculate water to feed tanning and liming drums, which will optimize this water resource.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00571-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectPROCESOS INDUSTRIALESes_ES
dc.subjectCURTIEMBREes_ES
dc.subjectAFLUENTEes_ES
dc.subjectSULFUROes_ES
dc.subjectCROMO HEXAVALENTEes_ES
dc.subjectCOAGULACIÓNes_ES
dc.subjectFLOCULACIÓNes_ES
dc.subjectSEDIMENTACIÓNes_ES
dc.subjectCARACTERIZACIÓNes_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para la curtiduría San Isidro de la ciudad de Ambato.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalPuente Guijarro, César Arturo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00571.pdf6,01 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons