Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/14304
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYanchapanta Bastidas, Vilma Nohemí-
dc.contributor.authorCarrasco Cazco, María Zuleima-
dc.date.accessioned2021-01-15T18:57:25Z-
dc.date.available2021-01-15T18:57:25Z-
dc.date.issued2020-08-28-
dc.identifier.citationCarrasco Cazco, María Zuleima. (2020). Simulación de un fantoma de mama para dosimetría, utilizando Montecarlo. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/14304-
dc.descriptionEl presente trabajo de investigación tuvo como finalidad de simular un fantoma de mama para el análisis de dosimetría haciendo uso del método Montecarlo. Para ello se desarrolló un modelo de fantoma de mama y los dispositivos del equipo de mamografía tales como, un blanco de Mo con un filtro de Mo para 26, 28 y 30 keV, la capa hemirreductora de Al y la paleta compresora de policarbonato. El fantoma de mama tuvo la forma de una caja que se encuentra a una distancia de 600 mm desde la fuente. Para el análisis dosimétrico se consideró tres espesores de compresión de mama 40, 45 y 50 mm cada uno con cinco composiciones del tejido mamario 1:99, 25:75, 50:50, 75:25, 99:1 (T. glandular: T. adiposo). Los materiales para la conformación de los dispositivos y del fantoma se tomó de las bases de datos NIST e ICRU 44 presentes en la plataforma GAMOS. Se determinó que la energía depositada en cada volumen en función del kilovoltaje fue directamente proporcional, mientras que en función del espesor de mama comprimida tuvo una relación inversamente proporcional a la composición del fantoma de la mama. La Dosis Glandular Media (DGM) por fotón disminuyó a mayor porcentaje de tejido glandular y espesor de mama comprimida. La DGM en composición estándar (50:50), analizada en 33.55, 38.55 y 43.55 mm de espesor aumenta, además se encuentra dentro del límite de referencia. En conclusión, la simulación fue útil para el análisis de dosimetría en mama, y se recomienda extender el estudio simulando un fantoma de mama tipo antropomórfico, además de contrastar los datos simulados con datos reales recolectados en centros de imagenología, establecer niveles de referencia de esta técnica radiológica en el país.es_ES
dc.description.abstractThe present research was aimed to simulate a breast phantom in order to perform the dosimetry analysis applying the Montecarlo method. It was developed a breast phantom model and the devices of mammography equipment such as, a Mo target with a Mo filter for 26, 28 and 30 keV, the half-conductor layer of Al and the polycarbonate compressor paddle. The breast phantom had a box shape and was located 600 mm far from the source. For dosimetric analysis, the study considered three breast compression thicknesses 40, 45 and 50 mm each one with five compositions of breast tissue 1:99, 25:75, 50:50, 75:25, 99:1 (glandular T. : adipose T.) The materials for the formation of the devices and the phantom were taken from the NITS and ICRU 44 databases present on the GAMOS platform. It was determined that the energy deposited in each volumen as a function of the kilovoltage it was directly proportional, while depending on the thickness of the compressed breast, it had an inversely proportional relationship to the composition of the breast phantom. The Mean Glandular Dose (MGD) per photon decreased to a higher percentage of glandular tissue and thickness of compressed breast. The MGD in standard compositions (50:50), analyzed in 33.55, 38.55 and 43.55 mm thickness increases, it is also within the reference limit. In conclusion, the simulation was useful for the analysis of dosimetry in the breast, and it is recommended to extend the study by simulating and anthropomorphic breast phantom, in addition to contrasting the simulated data with real data collected in imaging centers, establishing reference levels of this radiological technique in the country.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00104-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectFANTOMA DE MAMAes_ES
dc.subjectDOSIMETRÍAes_ES
dc.subjectPLATAFORMA DE SIMULACIÓN GAMOSes_ES
dc.subjectDOSIS GLANDULAR MEDIA (DGM)es_ES
dc.subjectBLANCO DEL TUBO DE RAYOS Xes_ES
dc.titleSimulación de un fantoma de mama para dosimetría, utilizando Montecarloes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalSaez Paguay, Miguel Ángel-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00104.pdf2,4 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons