Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/20819
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVeloz Chérrez, Diego Fernando-
dc.contributor.authorMora Campana, Marcela Estefania-
dc.date.accessioned2024-04-26T13:46:46Z-
dc.date.available2024-04-26T13:46:46Z-
dc.date.issued2022-06-24-
dc.identifier.citationMora Campana, Marcela Estefania. (2022). Diseño e implementación de un prototipo de sistema IOT para la monitorización de datos de presión arterial a través de un sensor fotoelectrónico. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/20819-
dc.descriptionEl objetivo del presente trabajo de integración curricular fue diseñar e implementar un prototipo de sistema IoT para la monitorización de datos de presión arterial a través de un sensor fotoelectrónico, se optó por el diseño y la implementación de un prototipo de sistema en internet de las cosas, bajo ambientes de dispositivos móviles con Android para la monitorización de datos de presión arterial a través de un sensor fotoelectrónico. Permite tomar los datos de presión arterial sistólica y diastólica del paciente mediante el sensor fotoelectrónico y la tarjeta de desarrollo, luego de ello procede a enviar la información a un servidor web almacenándola en un gestor de base de datos, por consiguiente, en la aplicación móvil se admite el registro del paciente en el sistema y el acceso a los resultados de la información de presión arterial. Para poder determinar el correcto funcionamiento del prototipo biomédico, se realizó la comparación conjunta de la toma de información arterial con la ayuda del equipo médico a mujeres mayores a 60 años, las pruebas se realizaron a 11 pacientes en la clínica metropolitana, siendo las muestras utilizadas para los cálculos y la comparación de resultados entre el equipo médico y el prototipo biomédico: Una vez realizada la medición y con los datos obtenidos indica que el prototipo implementado es confiable. Los resultados fueron presentados en la aplicación móvil. Se concluye que mediante la aplicación móvil es posible mostrar el diagnóstico del paciente conjuntamente con los cálculos de presión arterial además de los valores del monitoreo, donde el médico tratante será quien dictamine y valide el tipo de hipertensión y el tratamiento del paciente :Se recomienda que para el diseño y la implementación de un prototipo de sistema IoT para la monitorización de datos de presión arterial, debido a futuras investigaciones el uso de más sensores para precisar la medición de la Presión Arterial.es_ES
dc.description.abstractThe objective of this curricular integration work was to design and implement a prototype of an IoT system for monitoring blood pressure data through a photoelectronic sensor, it was decided to design and implement a prototype system in the internet of things, under Android mobile device environments for blood pressure data monitoring through a photoelectronic sensor. It allows taking the systolic and diastolic blood pressure data of the patient through the photoelectronic sensor and the development card, after which it proceeds to send the information to a web server, storing it in a database manager, therefore, in the mobile application patient registration in the system and access to blood pressure information results are supported. In order to determine the correct functioning of the biomedical prototype, the joint comparison of arterial information collection was carried out with the help of the medical team to women over 60 years of age, the tests were carried out on 11 patients in the metropolitan clinic, the samples used to be for calculations and comparison of results between the medical equipment and the biomedical prototype: Once the measurement has been made and with the data gotten, it indicates that the implemented prototype is reliable. The results were presented in the mobile application. It is concluded that through the mobile application it is possible to show the patient's diagnosis together with the blood pressure calculations in addition to the monitoring values, where the treating physician will be the one who dictates and validates the type of hypertension and the patient's treatment: It is recommended that for the design and implementation of a prototype IoT system for monitoring blood pressure data, due to future research the use of more sensors to accurately measure blood pressure.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;98T00363-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINTERNET DE LAS COSASes_ES
dc.subjectSENSOR FOTOELECTRONICOes_ES
dc.subjectHIPERTENSIONes_ES
dc.subjectPRESION ARTERIALes_ES
dc.subjectESP32es_ES
dc.subjectSENSOR MAX32664es_ES
dc.titleDiseño e implementación de un prototipo de sistema IOT para la monitorización de datos de presión arterial a través de un sensor fotoelectrónico.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMoreno Montenegro, Franklin Geovanni-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
98T00363.pdf4,4 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons