Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/20923
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMoreno Avilés, Hugo Oswaldo-
dc.contributor.authorGranizo Marcillo, Paola Alejandra-
dc.date.accessioned2024-05-01T22:00:56Z-
dc.date.available2024-05-01T22:00:56Z-
dc.date.issued2023-04-20-
dc.identifier.citationGranizo Marcillo, Paola Alejandra. (2023). Implementación de un prototipo de un sistema de red biométrica para el control de saturación de oxígeno con la tecnología bluetooth. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/20923-
dc.descriptionEl presente Trabajo de Titulación tuvo como objetivo el diseño e implementación de un prototipo de un sistema biométrico, con tecnología Bluetooth 2.4GHz, que permite la medición de la saturación de oxígeno en la sangre, con el registro y envío a una aplicación móvil (Android) y posterior, el envío a un base de datos en una página web. La construcción del prototipo fue en dos etapas, el transmisor que estaba conformado por cuatro dispositivos semejantes a un reloj, en el que se visualizó los niveles de saturación de oxígeno en tiempo real, tanto en porcentaje y en gráfica de la variación del mismo, valores que fueron enviados por los módulos Bluetooth HC-05 y recibidos por la siguiente etapa, el receptor, que fue conformado por una aplicación móvil, y una base de datos, los cuales contaban con una interfaz gráfica amigable con el usuario, en donde se visualizaba los datos personales del paciente, al igual que los niveles de saturación de oxígeno. Para la toma de resultados se consideró el uso de dos oxímetros de mercado los cuales serán comparados con los resultados obtenidos con el prototipo, en dos escenarios diferentes, el primer escenario fue cuando las personas se encontraban en reposo es decir unos 10min antes de tomar las medidas, y el segundo escenario se trató de realizar las medidas después de una actividad física. Finalmente, se concluyó que el prototipo funciona y optimiza el tiempo de los médicos en cuando a la vigilancia de la salud del paciente y se recomienda utilizar este prototipo para evitar el contacto directo de un paciente, y monitorearle de manera remota de manera eficaz y eficiente.es_ES
dc.description.abstractThe objective of this Titulation Work was the design and implementation of a prototype of a biometric system, with Bluetooth 2.4GHz technology, which allows the measurement of oxygen saturation in the blood, with the registration and sending to a mobile application (Android) and later, sending it to a database in a web page. The construction of the prototype was in two stages, the transmitter that is made up of four devices similar to a watch, in which the oxygen saturation levels are displayed in real time, both in percentage and in a graph of the variation of the same, values which are sent by the HC-05 Bluetooth modules and received by the next stage, the receiver, made up of a mobile application, and a database, which have a user-friendly graphical interface, where the data is displayed patient's personal data, as well as oxygen saturation levels. For the taking of results, the use of two market oximeters was considered, which were compared with the results obtained with the prototype, in two different scenarios, the first scenario was when the people were at rest, that is, about 10min before take the measurements, and in the second scenario it was attempted to perform the measurements after a physical activity. Finally, it was concluded that the prototype works and optimizes the time of doctors when it comes to monitoring the health of the patient and it is recommended to use this prototype to avoid direct contact with a patient, and monitor him or her remotely effectively and efficiently.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;98T00401-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTELECOMUNICACIONESes_ES
dc.subjectBLUETOOTHes_ES
dc.subjectTIEMPO REALes_ES
dc.subjectTECNOLOGÍA MÓVILes_ES
dc.subjectSATURACIÓN DE OXÍGENO EN LA SANGREes_ES
dc.subjectCOMUNICACIONES INALAMBRICASes_ES
dc.subjectSISTEMA BIOMÉTRICOes_ES
dc.subjectOXÍMETROes_ES
dc.titleImplementación de un prototipo de un sistema de red biométrica para el control de saturación de oxígeno con la tecnología bluetooth.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMora Chunllo, Verónica Elizabeth-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
98T00401.pdf7,22 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons