Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/3397
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYaulema Garces, Fausto Manolo-
dc.contributor.authorShiguango Chanaluisa, Nelson Alexander-
dc.date.accessioned2014-07-03T20:21:08Z-
dc.date.available2014-07-03T20:21:08Z-
dc.date.issued2014-07-03T20:21:08Z-
dc.identifier.citationShiguango Chanaluisa, Nelson Alexander. (2014). Diseño de una planta de tratamiento de aguas residuales para el centro poblado de la parroquia Tiputini del cantón Aguarico en la provincia de Orellana. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3397-
dc.descriptionEn la presente investigación se realizó el Diseño de una planta de tratamiento para el agua residual generada por el centro poblado de Tiputini en el Cantón Aguarico de la Provincia de Orellana. La investigación se llevó a cabo mediante el método descriptivo y cuantitativo, dando lugar a la caracterización física, química y microbiológica del Agua Residual, misma que se realizó mediante un muestreo simple y compuesto, utilizando envases ámbar y frascos estériles, guantes, mascarilla, cooler, etiquetas; analizándose parámetros de Potencial Hidrogeno (7.23), Coliformes Fecales (2.14*107 UFC), Solidos Suspendidos (120.2 mg/L), Solidos Totales (808.71 mg/L), Solidos Sedimentables (34 mg/L), Sulfatos (9.5 mg/L), Nitritos (0.03 mg/L), Nitratos (8.73 mg/L), Fosfatos (7.84 mg/L), DQO (436.05 mg/L), DBO5 (244.4 mg/L), Grasas Aceites (12.72 mg/L ) y Tensoactivos (5.36 mg/L). Con el método volumétrico se obtuvo un caudal promedio para el diseño de 117.465m3/día. La selección del sistema de tratamiento se realizó mediante las recomendaciones técnicas para pequeñas poblaciones y conocido el grado de carga contaminante del afluente, escogiéndose para el diseño un Canal de llegada, canaleta Parshall, Rejillas, Desarenador, Lecho de secado y Laguna artificial de flujo subsuperficial. Las dimensiones para las unidades de tratamiento son: El canal de llegada de dimensiones: L= 1.5m, A= 0.5m h= 0.61m; Rejilla: Lvarilla= 0.74m, evarilla= 12mm, nvarillas= 14; Canal Parshall: L= 1.52m, W= 0.15m, A= 0.39, h= 0.62m; Desarenador: L= 2.5m, A= 0.7m, h= 0.7 - 0.8m, Lechos de secado (4 unidades): L= 2.5m, A= 1.83m, h= 0.6-1m; Laguna Artificial (2): L= 43.62m, A= 21.75m, h= 0.7 - 0.9m. La cual está diseñada para 20 años y con una eficiencia en remoción de carga contaminante del 85%. Se recomienda al Gobierno Municipal del Cantón Aguarico la implantación de la planta de tratamiento con la finalidad de mitigar el impacto ambiental por las aguas residuales.es_ES
dc.description.abstractIn this research, the design of a wastewater treatment plant for the wastewater generated by the Tiputini town center in the Aguarico Canton of the Orellana Province was carried out. The research was carried out using the descriptive and quantitative method, resulting in the physical, chemical and microbiological characterization of the wastewater, which was done through a simple and composite sampling, using amber containers and sterile flasks, gloves, mask, cooler, labels; analyzing parameters of Hydrogen Potential (7. 23), Fecal Coliforms (2.14*107 CFU), Suspended Solids (120.2 mg/L), Total Solids (808.71 mg/L), Sedimentable Solids (34 mg/L), Sulfates (9. 5 mg/L), Nitrites (0.03 mg/L), Nitrates (8.73 mg/L), Phosphates (7.84 mg/L), COD (436.05 mg/L), BOD5 (244.4 mg/L), Oils and Fats (12.72 mg/L) and Surfactants (5.36 mg/L). The volumetric method yielded an average design flow of 117,465m3/day. The selection of the treatment system was made according to the technical recommendations for small populations and knowing the degree of pollutant load of the influent, choosing for the design an inlet channel, Parshall flume, grids, sand trap, drying bed and artificial subsurface flow lagoon. The dimensions for the treatment units are as follows: The arrival channel of dimensions: L= 1.5m, A= 0.5m h= 0.61m; Grate: Lgrid= 0.74m, evarilla= 12mm, nvarillas= 14; Parshall Channel: L= 1.52m, W= 0.15m, A= 0.39, h= 0.62m; Desander: L= 2.5m, A= 0.7m, h= 0.7 - 0.8m, Drying beds (4 units): L= 2.5m, W= 1.83m, h= 0.6-1m; Artificial Lagoon (2): L= 43.62m, W= 21.75m, h= 0.7 - 0.9m. The lagoon is designed for 20 years and has a pollutant load removal efficiency of 85%. It is recommended that the Municipal Government of Canton Aguarico implement the treatment plant in order to mitigate the environmental impact of wastewater.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0091-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectDISEÑO DE PLANTAS DE TRATAMIENTO DE AGUAes_ES
dc.subjectPLANTA DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectAGUARICO (CANTÓN)es_ES
dc.subjectTIPUTINI [CANTÓN]es_ES
dc.subjectPROVINCIA DE ORELLANAes_ES
dc.titleDiseño de una planta de tratamiento de aguas residuales para el centro poblado de la parroquia Tiputini del cantón Aguarico en la provincia de Orellanaes_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalErazo, Roberto-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0091.pdf4,81 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons