Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/3661
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVillacrés Alvarez, Mario Gustavo-
dc.contributor.authorIntriago Briones, Ana Julia-
dc.date.accessioned2015-01-06T15:09:10Z-
dc.date.available2015-01-06T15:09:10Z-
dc.date.issued2014-
dc.identifier.citationIntriago Briones, Ana Julia. (2014). Optimización del sistema de intercambiadores de calor del tren de precalentamiento de crudo de la Unidad no Catalíticas II en la Refinería Estatal Esmeraldas. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3661-
dc.descriptionOptimización del sistema de intercambiadores de calor de los trenes de precalentamiento de crudo de la unidad No Catalíticas II en la Refinería Estatal Esmeraldas. Para esta investigación se realizó la recolección de propiedades físico-químicas de fluidos e ingeniería detallada de cada intercambiador de tubo y coraza, se identificaron puntos para realizar mediciones de temperaturas mediante un pirómetro por 15 días laborables con un 100% de carga, se determinaron los flujos de entrada y salida con DCS Graphic, mediante indicadores de flujo con su respectivo histórico, todos estos datos se registraron en hojas de cálculo Excel para realizar la evaluación del circuito de precalentamiento mediante el empleo del Método de Kern, para determinar coeficientes de transferencia de calor, factores de ensuciamiento y caídas de presión. Los resultados con respecto al factor de ensuciamiento fueron de 0.00080 h ft2 ºF/BTU al C-E20, 0.00633 h ft2 ºF/BTU al C-E21, 0.00219 h ft2 ºF/BTU al C-E22, 0.33632 h ft2ºF/BTU al C-E44A/B, 0.00300 h ft2 ºF/BTU al C-E23 A/B, 0.00304 h ft2 ºF/BTU al C-E45, y 0,00277 h ft2 ºF/BTU al C-E46 A/B/C. Se planteó una propuesta de mejora técnica para la transferencia de calor en los sistemas de precalentamiento que consiste en un limpieza de coraza y baqueteo de tubos en los intercambiadores C-E21, C-E22, y C-E23 A/B y se propuso un cambio del haz de tubos al C-E44 A/B, para regresar al tren de precalentamiento a las condiciones de diseño. Para permitir el correcto funcionamiento del sistema y mejorar la trasferencia de calor se recomienda la implementación del presente estudio de optimización en la Unidad No Catalíticas II de Refinería Estatal Esmeraldas.es_ES
dc.description.abstractOptimization of exchangers system of heat of the pre-heating trains of crude of unit no Catalytic II in the State Oil Refinery Esmeraldas. For this research was made the collect of physic-chemical properties of fluid and detailed engineering of each exchanger of each shell and tube, were identified points for making temperatures measurements through a pyrometer during 15 working days with 100% of charge, were determined the flows into and out with DCS Graphic, by means of flow indicators with its respective historic, whole of these data were registered in Excel spread sheet to carry out the evaluation of pre-heating circuit with Kern Method, for determining heating transference coefficients, polluting factor and pressure drop. The results with respect to the polluting factor were of 0.00080 h ft2 ºF / BTU to C-E20, 0.00633 h ft2 F / BTU to C-E21, 0.00219 h ft2 F / BTU to C-E22, 0.33632 h ft2 F / BTU to C-E44A / B, 0.00300 h ft2 F / BTU to C-E23 A / B, 0.00304 h ft2 F / BTU to C-E45 and 0.00277 h ft2 F / BTU to C-E46 A / B / C. It was proposed a technical improvement for the heating transference in the pre-heating systems that consist in a shell cleaning and battered tubes in the exchangers C-E21, C-E22, and C-E23 A / B and was proposed a change of tube - bundle to C-E44 a / B, for returning to pre-heating train to the design conditions. To allow the correct functioning of system and improve heat transference, it is recommended the implementation of this optimization study in Unit No Catalytic II of Oil Refinery Esmeraldas.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00276-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectTEMPERATURAes_ES
dc.subjectTRANSFERENCIA DE CALORes_ES
dc.subjectFLUJOSes_ES
dc.subjectSISTEMA DE INTERCAMBIADORES DE CALORes_ES
dc.subjectTREN DE PRECALENTAMIENTOes_ES
dc.subjectUNIDAD NO CATALÍTICASes_ES
dc.subjectESMERALDAS (PROVINCIA)es_ES
dc.subjectMÉTODO DE KERNes_ES
dc.subjectINTERCAMBIADOR DE TUBO Y CORAZAes_ES
dc.subjectFACTORES DE ENSUCIAMIENTOes_ES
dc.subjectCAÍDAS DE PRESIÓNes_ES
dc.subjectCOEFICIENTES DE TRANSFERENCIA DE CALORes_ES
dc.titleOptimización del sistema de intercambiadores de calor del tren de precalentamiento de crudo de la Unidad no Catalíticas II en la Refinería Estatal Esmeraldas.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalChuiza Rojas, Marco Raúl-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a