dc.identifier.citationLópez Cáceres, Luis Antonio; Yépez Sinchiguano, Milton Plinio. (2015). Diseño e implementación de un laboratorio virtual para medir caída de presión y obtener datos en tiempo real usando LABVIEW y visual BASIC para mecánica de fluidos. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4486-
dc.descriptionEl diseño e implementación de un laboratorio virtual para medir la pérdida de energía en una válvula esférica mediante la adquisición de datos en tiempo real utilizando los software LabView y Visual Basic, tiene como objetivo automatizar la recopilación de datos experimentales y teóricos para obtener el coeficiente de pérdidas de carga . Al observar que los datos de presión y caudal provenientes de medidores de presión y caudalímetros se tomaban manualmente, se vio la necesidad de optimizar los equipos del Laboratorio de Mecánica de Fluidos, hecho que dio lugar a trabajar en el diseño, implementación y experimentación de un interfaz que reciba datos a través de dos sensores de presión ubicados antes y después de la válvula, que en forma paralela medirá volumen de flujo mediante un medidor tipo turbina. Una vez determinados los principales componentes para construir el sistema hidráulico, se instalaron dos transmisores de presión KOBOLD SEN-9601 y un medidor de flujo tipo GPI G1, que envían datos a la tarjeta de adquisición de datos NI 60001 encargada de procesarlos para transmitirlos a un PC que trabaja en interfaz utilizando los softwares específicos. Los resultados obtenidos en la experimentación muestran una clara tendencia de aumento del coeficiente de pérdidas de energía a medida que se cierra la válvula esférica mientras en forma paralela disminuye el caudal el objetivo de la investigación se cumplió al sistematizar la adquisición de datos, abriendo la posibilidad de realizar nuevas investigaciones que den solución a la disminución de la pérdida de presión. El estudio se complementa con la guía de Laboratorio, un plan de mantenimiento y las tablas de registro que orientarán un mejor funcionamiento del procedimiento.es_ES
dc.description.abstractThe design and implementation of a virtual laboratory for measuring the energy loss in a ball valve through the acquisition of data in real time using the LabView and Visual basic software, has as objective to automate the collection of experimental and theoretical data for obtaining the losses coefficient of charge. On noticing the pressure and flow data from pressure meters and flow meter were manually taken. It saw the need to optimize equipment laboratory of Fluid Mechanics. Fact which led to work on the design, implementation and testing of an interface that receives data through two pressure sensors located before and after the valve, which will measure in parallel way flow volume by a turbine-type meter. Having identified the main components to build the hydraulic system, it was installed two pressure transmitters Kobold SEN-8601 and a flow meter GPI G2, which send data to the card of data acquisition NI 6008 in charged of processing to be transmitted to a PC that works in an interface using specific soft wares. The results obtained in the experimentation show a clear trend of increase of the coefficient of energy loss as the ball valve is closed while in parallel way the flow rate decreases, the research objective was fulfilled to systematize data acquisition, opening the possibility for further research to provide solutions to lower pressure loss. The study is complemented by laboratory guide, a maintenance plan and log tables to guide better performance of the procedure.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;15T00595-
dc.subjectADQUISICIÓN DE DATOSes_ES
dc.subjectDISEÑO ELECTRÓNICOes_ES
dc.subjectPLAN DE MANTENIMIENTOes_ES
dc.subjectPLAN DE SEGURIDADes_ES
dc.subjectMECÁNICA DE FLUIDOSes_ES
dc.subjectLABORATORIO VIRTUAL ESPOCHes_ES
dc.titleDiseño e implementación de un laboratorio virtual para medir caída de presión y obtener datos en tiempo real usando LABVIEW y visual BASIC para mecánica de fluidoses_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalPomboza Floril, Cristina-
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00595.pdf2,62 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.