dc.identifier.citationOto Topon, Marco Antonio. (2016). Desarrollo de un Sistema Scada con base de datos según norma ISO 14224 para dos grupos electrógenos de la planta de generación eléctrica del ZPF bloque 18 - Petroamazonas EP. Escuela Superior Politécnica de Chimborazo.Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4597-
dc.descriptionEl presente trabajo consistió en el “Desarrollo de un sistema SCADA con base de datos según norma ISO 14224 para dos grupos electrógenos de la planta de generación eléctrica del ZPF Bloque 18 - PETROAMAZONAS EP”, localizado en la provincia de Orellana, este sistema permite el registro de fallas de forma estandarizada en tiempo real y el cálculo de indicadores claves de desempeño (KPI’s, por sus siglas en inglés) directamente desde la Interfaz Humano-Máquina (HMI), los indicadores seleccionados fueron: Disponibilidad, Mantenibilidad, Confiabilidad, Infiabilidad, Tiempo Medio para Reparación, Tiempo Medio entre Fallas, Tasa de fal lo, Tasa de reparación y Tiempo de inactividad. Se aplicaron los métodos Científico, Deductivo para obtener información teórico- práctica, necesarias para el desarrollo, implementación, pruebas funcionales y demostración de la aplicación. Se utilizó una arquitectura cliente-servidor, un controlador lógico programable (PLC), un sistema de base de datos SQL (Structured Query Language), y software de desarrollo SCADA que permitió establecer comunicación entre las variables de campo, los registros de las tablas y el HMI, mediante programación VBA (Visual Basic) y sentencias SQL. Al finalizar la implementación se obtuvo como resultado de confiabilidad del generador MG1: 52.37% y MG2 de 99.02%. En conclusión, la aplicación permitió obtener indicadores claves de desempeño en tiempo real, disponer de una base de datos más confiable mediante el registro de fallos basado en la norma ISO 14224:2006, adicionalmente, se presentaron los resultados del Análisis de Modos de falla y Efectos de dos grupos electrógenos. Se recomienda que el resultado de los indicadores sea analizado por profesionales en la gestión de mantenimiento para una correcta interpretación, adicionalmente, al ser un sistema estandarizado, se puede aplicar a equipos de similares características dentro de la industria petrolera.es_ES
dc.description.abstractThis research consisted of the “Development of a SCADA system with database according to the ISO 14224 standard for two generators of the power plant of ZPF Block 18 – Petroamazonas EP”, located in Orellana province, this system registers the fault records of a standardized real-time calculation of key performance indicators (KPI’s, for its acronym in English) directly from the Human-Machine Interface (HMI), the selected indicators were: availability, maintainability, reliability, unreliability, Mean Time To Repair, Mean Time Between Failures, Failure rate, Repair rate and downtime. The scientific and deductive methods were applied to gather theorical and practical information necessary for the development, implementation, functional testing and demostration of the application. A client-server structure was used, as well as a programmable logic controller (PLC), a database system SQL (Structured Query Languaje), and development software SCADA to establish communication among field variables, the tables records and the HMI, throughout VBA (Visual Basic) programming and SQL statements. After finishing the implementation the generator reliability results were MG1: 52.37% and MG2 99.02%. In conclusión, the application enabled to obtain key performance indicators in real time, provide a more reliable database through the fault records base on the ISO 14224:2006 standard, in addition, the two generators Failure Mode and Effects Analysis were presented. It is recommended to ask maintenance managements professinals to analyze the indicators results for a correct interpretation, furthermore, since it is an standardized system, it could be applied to eqipment with similar characteristics within the oil industry.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTIPEC;20T00675-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectANÁLISIS DE MODOS DE FALLA Y EFECTOS (FMEA)es_ES
dc.subjectBASE DE DATOSes_ES
dc.subjectBLOQUE 18 (CAMPO PETROLERO)es_ES
dc.subjectCONTROLADOR LÓGICO PROGRAMABLE (PLC)es_ES
dc.subjectNDICADOR CLAVE DE DESEMPEÑO (KPI)es_ES
dc.subjectLENGUAJE DE CONSULTA ESTRUCTURADO (SQL)es_ES
dc.subjectPETROAMAZONAS EPes_ES
dc.subjectSUPERVISIÓN, CONTROL Y ADQUISICIÓN DE DATOS (SCADA)es_ES
dc.titleDesarrollo de un Sistema Scada con base de datos según norma ISO 14224 para dos grupos electrógenos de la planta de generación eléctrica del ZPF bloque 18 - Petroamazonas EP.es_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.contributor.miembrotribunalAcuña Acurio, Edgar Roberto-
dc.contributor.miembrotribunalVélez Núñez, Paulina Andrea-
dc.rights.urihttps://creativecommons.org.//licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Maestrias: Modalidad Proyectos de Investigación y Desarrollo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
20T00675.pdf19,16 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons