dc.identifier.citationJiménez Idrovo, Jorge Luis. (2017). Diseño de una planta de tratamiento de aguas residuales domésticas para el sector Langasa y Jesús del Gran Poder, parroquia Mulliquindil-Santa Ana, cantón Salcedo. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6542-
dc.descriptionEl objetivo fue diseñar una Planta de Tratamiento de Aguas Residuales para el sector Langasa y Jesús del Gran Poder, Parroquia Mulliquindil-Santa Ana, Cantón Salcedo. Las comunidades actualmente carecen de infraestructuras físicas sanitarias como plantas de tratamiento de aguas residuales. La elaboración del estudio y diseño de una planta de tratamiento, se dio de acuerdo a los parámetros físico-químicos y microbiológicos que exige la norma vigente TULSMA. Luego de los análisis se identificó los parámetros fuera de norma: Hierro, Color, Demanda Bioquímuca de Oxígeno (DBO5), Demanda Química de Oxígeno (DQO), Detergentes, Coliformes fecales y Sólidos Suspendidos, consecuentemente se procedió a las pruebas de tratabilidad con lechos filtrantes arena-grava determinándose implementar una planta de tratamiento de aguas residuales convencional de: canal de captación –zona desbaste, seguida de un proceso de sedimentación mediante un cajón desarenador convencional, sedimentador con pantalla perforada , un filtro circular de flujo ascendente, para cuidado y protección del sistema, un cajón para el secado de lodos, este es uno de los sistemas más adecuados, convenientes al costo económico, para el tratamiento de aguas residuales especialmente para comunidades, urbanizaciones y barrios. El diseño se validó con una caracterización final del agua filtrada estos son: DBO5 64 mg/L, DQO 105 mg/L, Hierro 7 mg/L, Color 181 Und Co/Pt, Detergente 0,41 mg/L, Sólidos suspendidos 1 mg/L y Coliformes fecales 0,027 NMP/100ml, que cumple con todos requerimientos estructurales, estándares de calidad para la obtención de agua tratada que son descargadas directamente al Río Langasa y su entorno, su diseño disminuye la contaminación en los medios hídricos y su ecosistema. Se recomienda hacer un análisis de lodos (CREBIT) basados en la Norma, Manejo Ambientalmente Adecuado de Lodos Provenientes de Plantas de Tratamiento (REPAMAR).es_ES
dc.description.abstractThis research objective is to design a wastewater treatment plant for Langasa and Jesús del Gran Poder, Mulliquindil Santa Ana Parish, Salcedo Canton. These communities do not have sanitary infrastructure as wastewater treatment plants. This study and plant design is based according to chemical-physical and microbiological parameters demanded by the TULSMA (Unified Text of the Secondary Legislation of the Ministry of Environment) norm. After analyzing, it was possible to identify the parameters out of the norm such as: Iron, Color, Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), detergents, fecal coliforms and suspended solids. Consequently, the treatability tests with filtering beds made of sand-gravel were carried out determining the implementation of a conventional wastewater treatment plant which consists of collection channel-screening area, sedimentation process by means of a conventional grit chambers, sedimentation tank with perforated screen, a circular rising-flow filter and a mud drying chamber for care and protection of the system. This is one of the cheapest system for communities, urbanizations and neighborhoods. The design was validated with a final characterization about filtered water as follows: BOD5 64mg/L, COD 105 mg/L, color 181 U/Co Pt, detergent 0.41 mg/L, suspended solids 1mg/L and fecal coliforms 0,027 MPN/100ml, structural requirements and quality standards required to get treated water discharged in Langasa river and its surroundings. This present design reduces pollution in hydric systems and ecosystem. It is recommended to analyze muds CREBIT (Corrosive, Reactive, Explosive, Biological, Flammable and Toxic) based on the Norm, Adequate Environmental Management of muds coming from REPAMAR (Panamerican wastewater management net)es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00378-
dc.subjectPLANTA DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectAGUA RESIDUAL DOMÉSTICAes_ES
dc.subjectREJILLASes_ES
dc.subjectDESARENADOR CONVENCIONALes_ES
dc.subjectSEDIMENTADORes_ES
dc.subjectFILTRO CIRCULAR DE FLUJO ASCENDENTEes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.titleDiseño de una planta de tratamiento de aguas residuales domésticas para el sector Langasa y Jesús del Gran Poder, parroquia Mulliquindil-Santa Ana, cantón Salcedo.es_ES
dc.typebachelorThesises_ES