Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6990
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorJácome Valdez, Marcelo Antonio-
dc.contributor.authorNúñez Verdezoto, Tatiana Gissela;-
dc.contributor.authorCunachi Pazmiño, Carlos Andrés-
dc.date.accessioned2017-08-09T19:10:47Z-
dc.date.available2017-08-09T19:10:47Z-
dc.date.issued2017-07-03-
dc.identifier.citationNúñez Verdezoto, Tatiana Gissela; Cunachi Pazmiño, Carlos Andrés. (2017). Evaluación del ambiente térmico y mitigación en el confort térmico en los trabajadores en el área de lavandería sección secado del Hospital General Ambato. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6990-
dc.descriptionEl presente estudio consiste en la evaluación de las condiciones térmicas y la mitigación confort térmico a las cuales los operarios del área de lavandería sección secado del Hospital General Ambato están sometidos en su jornada laboral. Esta investigación tuvo su inicio con la evaluación cualitativa utilizando la matriz del INSHT, en la cual se indica cuando un riesgo es trivial, tolerable, moderado, importante, intolerable. Además se utilizó la norma NTP 330, para la identificación y evaluación de riesgos de manera cuantitativa y a continuación llenar la matriz propuesta por el Ministerio de Trabajo. Posteriormente se realizó las mediciones del riesgo más crítico que es el ambiente térmico con el método WBGT, el mismo que cuantifica el estrés térmico al que está sometido o soportando cada trabajador del área de lavandería sección secado en la jornada de trabajo, también como sustento de apoyo nos basamos en la norma NPT 74 Confort térmico-método Fanger el cual nos ayudó para determinar el confort térmico. A partir de las mediciones obtenidas procedimos a desarrollar cada uno de los cálculos de confort térmico basados en la norma NTP: 74 y diagnóstico del ambiente térmico mediante la norma NTP: 322 con el fin de conocer a que nivel de estrés térmico están expuestos los trabajadores del área de lavandería sección secado. Una vez realizada las mediciones se obtuvo como resultado un índice WBGT de 31.02°C y un 100% de personas insatisfechas. Se demostró que los trabajadores si se encuentran expuestos a estrés térmico y disconfort térmico razón por la cual planteamos una solución óptima con el propósito de mejorar el ambiente de trabajo favoreciendo a cada uno de los trabajadores.es_ES
dc.description.abstractThe present study consists of the evaluation of the thermal conditions and the thermal comfort mitigation to which the workers of the dry section laundry area of General Hospital Ambato are subjected in their working day. This investigation began with the qualitative evaluation using the INSHT matrix, which indicates when a risk is trivial, tolerable, moderate, significant, intolerable. In addition, the NTP 330 standard was used for the identification and evaluation of irrigation in a quantitative way and then filling the matrix proposed by the Ministry of Labour. Subsequently, the measurements of the most critical irrigation that is the thermal environment were performed with the WBGT method, the same that quantifies the thermal stress to which each worker in the laundry area is subjected or supported by drying section in the working day, also as sustenance of Support, It is based on the standard NTP 74 thermal comfort Fanger method which helped us to determine the thermal comfort. From the obtained measurements it is proceeded to develop each of the thermal comfort calculations based of the NTP standard: 74 and diagnosis of the thermal environment by means of the norm NTP: 322 in order to know to what level of thermal stress the workers are exposed of the dry section laundry area. Once the measurements taken, a WBGT index of 31.02° C and 100% of unsatisfied people. It was demonstrated that the workers are exposed to thermal stress and thermal discomfort reason for which it is proposed an optimal solution with the purpose of improving the work environment favoring each one of the workers.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;85T00452-
dc.rightsInfo:eu-repo/semantics/openAccesses_ES
dc.subjectDISEÑO ASISTIDO POR COMPUTADORA (CAD)es_ES
dc.subjectÍNDICE DE ESTRÉS TÉRMICO (WBGT)es_ES
dc.subjectCONFORT TÉRMICOes_ES
dc.subjectMÉTODO FANGERes_ES
dc.subjectAMBIENTE TÉRMICOes_ES
dc.subjectDISCONFORT TÉRMICOes_ES
dc.subjectGESTIÓN DE SEGURIDADes_ES
dc.titleEvaluación del ambiente térmico y mitigación en el confort térmico en los trabajadores en el área de lavandería sección secado del Hospital General Ambato.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCayán Martínez, Juan Carlos-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
85T00452.pdf14,59 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons