dc.identifier.citationBonilla Bayas, Jefferson Israel. (2018). Elaboración de un manual de procedimientos para el tomógrafo Toshiba Activion en el Departamento de imagenología del Hospital Provincial General Docente Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8363-
dc.descriptionLa presente investigación tuvo como finalidad la elaboración de un manual de procedimientos realizados en las zonas de cráneo, tórax y abdomen para el Tomógrafo TOSHIBA ACTIVION en el Hospital Provincial General Docente Riobamba. Se comenzó elaborando un manual de procedimiento de operación y la implementación de pruebas de control de calidad y protección radiológica, dentro de la sala de tomografía. Este manual fue elaborado, tomando como, base distintas referencias de instituciones y organismos nacionales e internacionales, además se tomó en cuenta los recursos y necesidades del hospital, asegurando la obtención de imágenes con buena calidad, y procurando trabajar con la dosis más baja posible. Debido a la falta de presupuesto del hospital, solo se ha ido realizando pruebas mecánicas y eléctricas del equipo, motivo por el cual se planteó realizar las mediciones de control de calidad y protección radiológica para controlar el funcionamiento del equipo. Para la implementación del control de calidad, se detallan las distintas pruebas como el control de exposición, calidad de imagen y de mantenimiento, las mismas que fueron medidas usando materiales como dosímetros, un kilovoltímetro, detector de temperatura, etc. Pero no todas las pruebas se realizaron, debido a falta de las claves de ingreso al sistema del tomógrafo y a la falta de equipo específico. Al final, los resultados en las pruebas de control de exposición, mantenimiento y protección radiológica se encuentran bajo los niveles establecidos por la Subsecretaría de Control de Aplicaciones Nucleares (SCAN), pero el valor promedio de radiación de fuga fue de 0,0089 mSv/h en las puertas de acceso de pacientes, siendo valores mayores a los que deberían ser medidos. Se recomienda que el departamento cuente con una persona especialista en control de radiaciones ionizantes, que aplique los distintos procedimientos y pruebas del equipo para garantizar la seguridad del personal.es_ES
dc.description.abstractThis investigation aimed at elaborating a manual of procedures performed in the areas of the skull, thorax and abdomen for the Tomograph TOSHIBA ACTIVION in the Provincial General Scholastic Hospital Riobamba. It was started by preparing a manual of operating procedures and the implementation of quality control and radiological protection test within the tomography room. This manual was prepared based on different references from national and international institution and organization, moreover, the resources and needs of the hospital were taken into account, ensuring the obtainment of images with good quality, and trying to work with the lowest possible dose. Due to the lack of budget of the hospital, only mechanical and electrical equipment test have been carried out, this is the reason why it was proposed to conduct the quality control and radiological protection measurements to control the operation of the equipment. For the implementation of quality control, it was detailed the distinct test such as exposure control, quality of image and maintenance, which were measure using materials such as dosimeters, a kilovoltmeter, temperature detector, etc. But not all the test were carried out due to the lack of access codes to the tomograph system and the lack of specific equipment. In the end, the results in the test of exposure control, maintenance, and radiological protection are below the levels established by the Regulatory Authority (SCAN), but the values of leakage radiation were 0,0089 mSv/h at the access doors of patients, being higher values than those that should be measure. It is recommended to have in the department a specialist in ionizing radiation control, who applies the different procedures and test of the equipment and to guarantee the safety of the personnel.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00054-
dc.subjectBIOFÍSICAes_ES
dc.subjectRADIOLOGÍAes_ES
dc.subjectTOMOGRAFÍA COMPUTARIZADAes_ES
dc.subjectPROTECCION RADIOLÓGICAes_ES
dc.subjectCONTROL DE CALIDADes_ES
dc.subjectDOSÍMETROSes_ES
dc.subjectDETECTOR DE TEMPERATURAes_ES
dc.subjectCONTROL DE EXPOSICIÓNes_ES
dc.subjectRADIACIÓN DE FUGAes_ES
dc.titleElaboración de un manual de procedimientos para el tomógrafo Toshiba Activion en el Departamento de imagenología del Hospital Provincial General Docente Riobamba.es_ES