Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8364
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBorja, Myrian Cecilia-
dc.contributor.authorMartínez Cruz, David Israel-
dc.date.accessioned2018-06-18T21:11:49Z-
dc.date.available2018-06-18T21:11:49Z-
dc.date.issued2018-03-
dc.identifier.citationMartínez Cruz, David Israel. (2018). Desarrollo de una herramienta computacional para la fusión de imágenes SPECT-TC en Matlab del Área de Medicina Nuclear convencional del Hospital Carlos Andrade Marín. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8364-
dc.descriptionEl objetivo del presente trabajo de investigación fue desarrollar una herramienta de fusión de imágenes médicas SPECT/TC y una aplicación de dosimetría interna para medir la dosis absorbida en pacientes del Hospital Carlos Andrade Marín (HCAM). Para ello se elaboró una interfaz gráfica (GUIDE) en MATLAB donde los algoritmos de fusión implementados fueron; Fusión Simple de Imágenes (Promedio Simple, Valor Máximo, Valor Mínimo, Análisis de Componentes Principales), Fusión basada en la Descomposición Piramidal (Pirámide Gaussiana, Pirámide Laplaciana, Pirámide de Contraste, Pirámide Morfológica), y Fusión basada en la transformada discreta de Wavelet (Transformada discreta de wavelets, Método de wavelets invariante a traslaciones), evaluados mediante diferentes medidas de calidad de imagen (Relación señal ruido máximo, Error cuadrático medio, Diferencia promedio, Diferencia máxima, Error absoluto normalizado, Correlación cruzada normalizada, y Contenido estructural). Se usó imágenes cerebrales, pélvicas y pulmonares procedentes de tecnologías radiológicas distintas (SPECT y TC) y relativas a un mismo corte del paciente. Además, se hizo un vínculo entre MATLAB y EXCEL para enlazar los datos de los valores de dosis media por actividad acumulada y la actividad inyectada a través de un algoritmo de dosimetría interna, siendo contrastado mediante ejemplos preexistentes. Se obtuvieron dos herramientas computacionales: la primera para la fusión de imágenes SPECT/TC idónea para el mejoramiento en la calidad en el diagnóstico por imagen, y la segunda para la obtención de la fracción de dosis absorbida de radioisótopos en pacientes oncológicos. Finalmente se recomienda desarrollar un estudio con la adquisición deimágenes médicas de otras fuentes: PET/TC para el mejoramiento de la calidad en el diagnóstico en el área de medicina nuclear molecular.es_ES
dc.description.abstractThe objective of the present work of investigation was to develop a fusion tool of medical images SPECT/CT and an application of internal dosimetry to measure the absorbed doses in patients of the Carlos Andrade Marin Hospital (HCAM). In doing so it was elaborated a graphical interface (GUIDE) in MATLAB the algorithms of implemented fusion were: Simple fusion of images (Simple Average, Maximum Value, Minimum Value, Principal Component Analysis), Fusion based in the Pyramidal Decomposition (Gaussian Pyramid, Laplacian Pyramid, Contrast Pyramid, Morphological Pyramid), and Fusion based in the discrete transformed of Wavelet (Discrete Wavelet Transform, Method of Wavelet Invariant to Movement), evaluated through different sizes of quality of image (Peak Signal to Noise Ratio, Mean Square Error, Average Difference, Maximum Difference, Normalized Absolute Error, Normalized Cross Correlation, and Structural Content) . It was used brain, pelvic and pulmonary images originated in diverse radiological technologies (SPECT and CT) and related to the same cut of the patient. Also, it was made a link between MATLAB and EXCEL to connect the data of the values of media doses for accumulated activity and the activity injected through an algorithm of internal dosimetry, being contrasted by means of preexisting examples. Two computational tools were obtained: the first for the fusion of SPECT/CT suitable for the enhancement in the quality in the diagnostic per image, and the second for the acquisition of the fraction of absorbed dose of radioisotope on oncological patients. Finally, it was recommended it to develop a study with the acquisition of medical images of another source: PET/CT for the strengthening of the quality in the diagnostic in the area of molecular nuclear medicine.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00055-
dc.subjectBIOFÍSICAes_ES
dc.subjectMEDICINA NUCLEARes_ES
dc.subjectTOMOGRAFÍA COMPUTARIZADA (TC)es_ES
dc.subjectTOMOGRAFÍA COMPUTARIZADA DE EMISIÓN MONOFOTÓNICA (SPECT)es_ES
dc.subjectMATLAB (SOFTWARE)es_ES
dc.subjectGRAPHICAL USER INTERFASE DEVELOPMENT ENVIRONMENT (GUIDE)es_ES
dc.titleDesarrollo de una herramienta computacional para la fusión de imágenes SPECT-TC en Matlab del Área de Medicina Nuclear convencional del Hospital Carlos Andrade Marín.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalGonzáles López, Nadia-
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00055.pdf12,56 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.