Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8440
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuerra Salazar, José Enrique-
dc.contributor.authorCastillo Sosa, Isabel Juritsa-
dc.contributor.authorMurillo Paguay, Abel Santiago-
dc.date.accessioned2018-07-19T16:14:12Z-
dc.date.available2018-07-19T16:14:12Z-
dc.date.issued2017-12-
dc.identifier.citationCastillo Sosa, Isabel Juritsa; Murillo Paguay, Abel Santiago. (2017). Diseño de una red de comunicaciones para la medición y control del consumo de agua potable en tiempo real para la parroquia Yaruquíes perteneciente a la ciudad de Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8440-
dc.descriptionEl objetivo del trabajo de titulación fue diseñar una red de comunicaciones para la medición y control del consumo de agua potable en tiempo real para la parroquia Yaruquíes perteneciente a la ciudad de Riobamba. Para el diseño de la red se investigó sobre la tecnología existente, factores y dispositivos que se ajusten a los requerimientos de la red, realizando una simulación de la misma, que permitió verificar la factibilidad de implementar un prototipo de la red. Consta de tres etapas: medición de consumo de agua potable, transmisión de datos, control y monitorización en tiempo real, para lo cual se implementó un medidor inteligente partiendo del medidor tradicional incorporándole un sensor de efecto hall y un módulo Wi-Fi ESP8266, que por medio de comunicación inalámbrica a través del punto de acceso (AP) publica los datos hacia el servidor Broker MQTT que es el intermediario de la comunicación. Se trabajó con el paquete de desarrollo Delphi Starter para crear una Interfaz Gráfica de Usuario donde se visualiza el consumo en tiempo real y el gestor de base de datos MySQL que almacena la información. La eficiencia de la red se determinó mediante simulaciones y pruebas reales con respecto a la conectividad, donde el dispositivo de medición presenta errores de lectura de 0.06 litros, cobertura máxima de -80 dBm y ancho banda mayor a 900 Kbps para una conexión estable con el AP, el tiempo de transmisión y control de datos en toda la red no debe ser mayor a 2s. Se concluye que la red de comunicación implementada junto con el medidor inteligente, mejora tiempos y procesos de operación, con relación a la lectura convencional. Se recomienda que para que los medidores inteligentes no pierdan conexión a la red se implementen enrutadores inalámbricos adicionales, en especial en zonas donde la intensidad de señal sea más baja.es_ES
dc.description.abstractThe aim of the degree work was to design a communications network for the measurement and control of drinking water consumption in real time for the parish of Yaruquies belonging to the city of Riobamba. For the design of the network, the existing technology, factors, and devices that adjust to the requirements of the network were investigated, performing a simulation of the same, which allowed verifying the feasibility of implementing a prototype of the network. It consists of three stages: drinking water consumption measurement, data transmission, real-time monitoring control, for which an intelligent meter was implemented starting from the traditional meter incorporating a hall effect sensor and a Wi-Fi module ESP8266, which through wireless communication through the access point (AP) it publishes the data to the Broker MQTT server that is the intermediary of the communication. We worked with the Delphi Starter development package to create a User Graph interface where the consumption in real time is visualized and the MySQL database manager that stores the information. The efficiency of the network was determined by simulations and real tests with respect to connectivity, where the measurement device has reading errors of 0.06 liters, maximum coverage of 80 dBm and a bandwidth greater than 900 Kbps for a stable connection with the AP, the time of transmission and control of data throughout the network should not be greater than 2s. It is concluded that the communication network implemented together with the smart meter improves times and operation processes, in relation to conventional reading. It is recommended that for the smart meters, no connection to the network be lost, additional wireless routers should be implemented, especially in areas where the signal strength is lower.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;98T00187-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectRED DE COMPUTADORESes_ES
dc.subjectCOMUNICACIONES INALÁMBRICASes_ES
dc.subjectWIFI (TECNOLOGÍA)es_ES
dc.subjectMEDICIÓN INTELIGENTEes_ES
dc.subjectBROKER MQTT (HARDWARE-SOFTWARE)es_ES
dc.subjectMEDICIÓN AGUA POTABLEes_ES
dc.subjectCONTROL DE SUMINISTRO DE AGUAes_ES
dc.titleDiseño de una red de comunicaciones para la medición y control del consumo de agua potable en tiempo real para la parroquia Yaruquíes perteneciente a la ciudad de Riobamba.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZúñiga Vinueza, Wilson Armando-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
98T00187.pdf3,61 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons