Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8567
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorChuiza, Marco-
dc.contributor.authorRamírez Tierra, Yajaira Natalia-
dc.date.accessioned2018-08-01T18:37:33Z-
dc.date.available2018-08-01T18:37:33Z-
dc.date.issued2017-12-
dc.identifier.citationRamírez Tierra, Ramírez Tierra. (2017). Diseño de la planta de tratamiento de aguas residuales de la parroquia Santa Fe de Gálan del cantón Guano. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8567-
dc.descriptionEl presente proyecto técnico tiene como objetivo el diseño de la planta de tratamiento de aguas residuales para la parroquia Santa Fe de Galán del Cantón Guano, ya que dicha agua es descargada directamente al riachuelo (SN) y a los terrenos cultivables que se encuentran alrededor de la población, siendo un problema que debe ser atendido por la contaminación que provoca, mediante la caracterización físico – químico y microbiológico del agua residual donde se determinó: sulfuro, nitrógeno total, Demanda Bioquímica de Oxigeno (DBO), Demanda Química de Oxigeno (DQO), coliformes fecales, coliformes totales, sólidos suspendidos totales, aceites y grasas y tensoactivos son parámetros que se encontraban fuera de los límites permisibles de la norma, de tal manera que se tomó como referencia al índice de biodegradabilidad que es el resultado de la caracterización de DBQ y la DQO que da como resultado un valor de 1,71 esto indica que la materia orgánica es moderadamente biodegradable permitiendo la selección de un tratamiento físico – químico, se empezó con pruebas de tratabilidad mediante test de jarras determinando los reactivos químicos que serán utilizados para tratar el agua, en este caso el sulfato de aluminio y Policloruro de Aluminio (PAC) fueron óptimos, de tal manera que la concentración del sulfato de aluminio es de 30,2 kg/dia y la concentración del PAC es de 50,4 kg/dia. La validación de parámetros físicos – químicos y microbiológicos del agua tratada dan como resultado: sulfuro 0,3 mg/l, nitrógeno total 40 mg/l, DBO 38 mg/l, DQO 90 mg/l, coliformes fecales ausencia, sólidos suspendidos totales 86 mg/l, aceites y grasas 24 mg/l y tensoactivos 0,46 mg/l, el sistema se establece de la siguiente manera: rejillas, canal de entrada rectangular, tanque de sedimentación, tanque de coagulación, tanque floculador, tanque de sedimentación secundario , paletas de agitación tipo turbina de 6 palas y eras de secadoes_ES
dc.description.abstractThe objective of this research was the design of the sewage treatment plant for the Santa Fe de Galán Parish, Guano Canton, since this water is discharged directly to the stream (SN) and to the cultivable land that is around the population, being a problem that must be addressed because of the pollution that it causes, by means of the physical - chemical and micro - logical characterization of the residual water where it was determined: sulfur, total nitrogen, Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), fecal coliforms, total coliforms, total suspended solids, oils and fats and surfactants are parameters that are outside the norm's permissible limits; in such a way that, the biodegradability index was taken as reference which is the result of the characterization of DBQ and the COD resulting in a value of 1.71, this indicates that the organic matter is moderately biodegradable allowing the selection of a treatment physical - chemical, it was started with treatability tests through jug test determining the chemical reagents that will be used to treat the water, in this case aluminum sulfate and aluminum polychloride (APC) were optimal. So that, the concentration of aluminum sulfate is of 30.2 kg / day, and the concentration of Aluminum Polychloride (APC) is 50.4 kg / day. Validation of physical - chemical and microbiological parameters of the treated water results in: sulfur 0.3 mg /1, total nitrogen 40 mg /1, BOD 38 mg /1, COD 90 mg /1, absence fecal coliforms, total suspended solids 86 mg /1, oils and fats 24 mg /1, and surfactants 0.46 mg /1, the system is established as follows: gratings, rectangular input channel, sedimentation tank, coagulation tank, floculator tank, secondary sedimentation tank, agitation blades type turbine of 6 blades and times of drying.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00420-
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA SANITARIAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectDEMANDA BIOQUÍMICA DE OXÍGENO (DBQ)es_ES
dc.subjectDEMANDA QUÍMICA DE OXÍGENO (DQO)es_ES
dc.titleDiseño de la planta de tratamiento de aguas residuales de la parroquia Santa Fe de Gálan del cantón Guano.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalBurbano, Diego-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00420.pdf2,61 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.