Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8602
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGonzález López, Nadia Aimee-
dc.contributor.authorValencia Mina, Adrián Andrés-
dc.date.accessioned2018-08-06T20:32:01Z-
dc.date.available2018-08-06T20:32:01Z-
dc.date.issued2018-06-
dc.identifier.citationValencia Mina, Adrián Andrés. (2018). Determinación de la dosimetría de radiación externa en pacientes con hipertiroidismo y cáncer de tiroides tratados con IODO-131 en el Área de Medicina Nuclear del Hospital “Carlos Andrade Marín” IESS – Quito. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8602-
dc.descriptionEl objetivo del trabajo de titulación fue determinar la dosimetría de radiación externa en pacientes con Hipertiroidismo y Cáncer de Tiroides tratados con Iodo-131 en el Área de Medicina Nuclear del Hospital “Carlos Andrade Marín” IESS – Quito (HCAM) en el periodo octubre 2017 a febrero 2018. Para ello se utilizó un detector Geiger Muller Thermo Scientific ubicado a un metro de distancia a la altura del cuello, abdomen y pulmones. Los pacientes objeto de estudio se clasificaron en dos grupos: el grupo I que corresponden a pacientes con Hipertiroidismo y grupo II pacientes con Cáncer de Tiroides. En el caso de los pacientes con cáncer de tiroides se tuvo en cuenta los procederes médicos realizados: Tiroidectomía Casi Total, Tiroidectomía Total y el estadio de la enfermedad. Los resultados muestran que los valores obtenidos de tasa de dosis para ambos grupos de pacientes no superan los 35 microsievert/h recomendados por los organismos internaciones para el alta radiológica. Estos valores de tasa de dosis se sugieren que sean analizados y considerados por la oficina de seguridad y protección radiológica del HCAM.es_ES
dc.description.abstractThe aim of the titling work was to determine the external radiation dosimetry in patients with Hyperthyroidism and Thyroid Cancer treated with iodine-131 in the Nuclear Medicine Area of the "Carlos Andrade Marin" IESS-Quito Hospital (HCAM) period October 2017 to February 2018. For this purpose, the Geiger Muller Thermo Scientific detector, located one meter away from the neck, abdomen and lungs, was used. The patients under study were classified into two groups: group I corresponded to patients with hyperthyroidism and group II patients with thyroid cancer. In the case of patients with thyroid cancer, the medical procedures carried out were taken into account. Almost total thyroidectomy, Total thyroidectomy and the stage of the disease. The results show that the values obtained from dose rate for stage of the disease. The results show that the values obtained from the dose rate for both groups of patients do not exceed 35 microsievert/h recommended by international organizations for radiological discharge. These dose rate values are suggested to be analyzed and considered by the radiological safety and security office of HCAM.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00061-
dc.subjectBIOFÍSICAes_ES
dc.subjectMEDICINA NUCLEARes_ES
dc.subjectTASA DE DOSISes_ES
dc.subjectDOSIMETRÍAes_ES
dc.subjectPROTECCIÓN RADIOLÓGICAes_ES
dc.subjectHIPERTIROIDISMOes_ES
dc.subjectCÁNCER DE TIROIDESes_ES
dc.titleDeterminación de la dosimetría de radiación externa en pacientes con hipertiroidismo y cáncer de tiroides tratados con IODO-131 en el Área de Medicina Nuclear del Hospital “Carlos Andrade Marín” IESS – Quito.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalYanchapanta Bastidas, Vilma Nohemí-
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00061.pdf4,51 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.