dc.identifier.citationManobanda Guamán, Rocío Elizabeth. (2018). Distribución de los coeficientes de atenuación lineal en la cavidad abdominopélvica de un fantoma antropomorfo para dosimetría interna con Tc-99m en el Hospital Carlos Andrade Marín. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8973-
dc.descriptionEl objetivo fue determinar la distribución de los coeficientes de atenuación lineal en la cavidad abdominopélvica de un fantoma antropomorfo para dosimetría interna utilizando Tc-99m en el Hospital Carlos Andrade Marín. Se realizó una tomografía computarizada al fantoma antropomorfo para delimitar la cavidad abdominopélvica, se distribuyó una fuente puntual de Tc99m en cada punto del corte axial para la adquisición de los datos y cálculo de los coeficientes de atenuación lineal de cada uno de los órganos, y luego determinar la dosis absorbida en hígado, y riñón por medio del método de los coeficientes. Como resultado se obtuvo un coeficiente de atenuación lineal promedio de u=0.158±0.012 cm -1, cuyo resultado indica que el fantoma antropomorfo es radiológicamente equivalente al tejido blando. Considerando el hígado como órgano fuente la dosis absorbida de los órganos de la cavidad abdominopélvica es: 1,035 cGy, 0,659 cGy, 0,628 cGy y 0,434 cGy para bazo, hígado, riñón y ovario respectivamente; mientras que al considerar el riñón como órgano fuente la vejiga, riñón, ovarios y testículos reciben una dosis de 0,29 cGy, 0,092 cGy, 0,018 cGy y 0,01 cGy respectivamente. Se determinó que los valores se encuentran dentro de los niveles máximos permisibles para el diagnóstico médico en Medicina Nuclear y a la vez se recomienda continuar esta investigación con herramientas computacionales.es_ES
dc.description.abstractThe objective was to determine the distribution of linear attenuation coefficients in the abdominopelvic cavity of an anthropomorphic phantom for internal dosimetry using Tc-99m at the Carlos Andrade Marín Hospital. A computed tomography was performed to the anthropomorphic phantom to delimit the abdominal-pelvic cavity, a point source of Tc-99m was distributed in each point of the axial cut for the acquisition of the data and calculation of the coefficients of linear attenuation of each of the organs, and then determine the absorbed dose in liver and kidney by means of the coefficient method. As a result, an average linear attenuation coefficient of u= 0.158 ± 0.012 cm-1 was obtained, it indicates that the anthropomorphic phantom is radiologically equivalent to the soft tissue. Considering the liver as the source organ, the absorbed dose of the organs of the abdominopelvic cavity is: 1.035 cGy, 0.655 cGy, 0.628 cGy and 0.434 cGy for spleen, liver, kidney and ovary respectively; whereas when considering the kidney as a source organ the bladder, kidney, ovaries and testes receive a dose of 0.29 cGy, 0.092 cGy, 0.018 cGy and 0.01 cGy respectively. It was determined that the values are within the maximum permissible levels for the medical diagnosis in Nuclear Medicine and at the same time it is recommended to continue this investigation with computational tools.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00069-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectMEDICINA NUCLEARes_ES
dc.subjectFANTOMA ANTROPOMORFOes_ES
dc.subjectCOEFICIENTES DE ATENUACIÓN LINEALes_ES
dc.subjectCAVIDAD ABDOMINOPÉLVICAes_ES
dc.subjectDOSIMETRÍA INTERNAes_ES
dc.titleDistribución de los coeficientes de atenuación lineal en la cavidad abdominopélvica de un fantoma antropomorfo para dosimetría interna con Tc-99m en el Hospital Carlos Andrade Marín.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalOrmaza Hugo, Rosa Maricela-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00069.pdf2,02 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons