Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/9209
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuerra Salazar, José Enrique-
dc.contributor.authorSaqui Valla, Jofre Ernesto-
dc.date.accessioned2018-11-22T19:42:57Z-
dc.date.available2018-11-22T19:42:57Z-
dc.date.issued2018-04-
dc.identifier.citationSaqui Valla, Jofre Ernesto. (2018). Implementación de un prototipo electrónico inalámbrico para supervisión, aviso y control de gases contaminantes en invernaderos artesanales. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/9209-
dc.descriptionSe implementó un Prototipo Electrónico Inalámbrico de Supervisión, Aviso y Control de gases contaminantes en invernaderos artesanales, es un prototipo de bajo costo, fácil instalación y manejo.Con el proyecto planteado se espera tener un impacto social y económico favorable para la población que se dedica a la explotación agraria en invernaderos artesanales donde la concentración de gases perjudiciales para la salud puede ser crítica. El prototipo tiende a ser escalable y permite el monitoreo por zonas de las variables de NH3, CO, O3, NOx y temperatura. Consta de tres módulos, dos de ellos basados en la plataforma Arduino, se comunican mediante radiofrecuencia basada en el estándar IEEE 802.15.4 de WPANs con un alcance máximo de 510 metros con línea vista y hasta 50 metros en interiores. El nodo sensor recolecta y envía la información a los módulos restantes. El módulo de supervisión y control permite la visualización de las mediciones con hora y fecha, almacena la información del día en una tarjeta MicroSD y permite acceder a partir de su pantalla táctil a información referente a los niveles de temperatura y de contaminación permitidos. El módulo de aviso por su parte se encarga de comparar la información procesada con los límites de alerta preestablecidos y enviar un mensaje con los valores actuales indicando que variables están fuera del rango. De las pruebas realizadas se comprobó que el prototipo tiene un error medio de 0.32 °C en la medición de la variable de temperatura. Y un error medio menor a 15 ug/m3 para las variables de contaminación. Se concluye que el prototipo es considerado como una mini estación de supervisión de la calidad del aire, por lo que su uso no se limita a ambientes cerrados. Se recomienda incorporar al prototipo sensores de Dióxido de Azufre (SO2), de PM2.5, PM10 para disponer de una estación de supervisión de calidad de aire completa.es_ES
dc.description.abstractA Wireless Supervisory Electronic Prototype was implemented. Notice and Control of polluting gases in artisanal greenhouses, is a low cost prototype, easy installation and management. With the proposed project is expected to have a favorable social and economic impact for the population that is dedicated to agricultural exposure in artisanal greenhouses where the concentration of harmful gases for health can be critical. The prototype tends to be scalable and allows zone monitoring of the variables of NH3, CO, C3, NOx and temperature. It consists of three modules, two of them based on the Arduino platform, they are communicated by radiofrequency based on the IEEE 802.15.4 standard of WPANs with a maximum range of 510 meters with line of sight and up to 50 meters indoors. The sensor node collects and sends the information to the remaining modules. The monitoring and control module allows the visualization of the measurements with time and date, stored the information of the day in a MicroSD card and allows access from its touch screen to information regarding the allowed temperature and contamination levels. The warning module on the other hand is responsible for comparing the processed information with the pre-established warning limits and sending a message with the current values indicating which variables are out of range. From the tests carried out, it was found that the prototype has an average error of 0.32 ° C in the measurement of temperature variable. And an average error of less than 15ug/m3 for the pollution variables. It is concluded that the prototype is considered as a mini air quality monitoring station, so its use is limits to closed environments. It is recommended to incorporate sensors of Sulfur Dioxide (SO2), PM2.5, PM10 into the prototype to have a complete air quality monitoring station.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;108T0252-
dc.subjectPROTOTIPO INALÁMBRICOes_ES
dc.subjectCOMPUESTOS ORGÁNICOS VOLÁTILES (VOCs)es_ES
dc.subjectCONTROL DE EMISIÓN DE GASESes_ES
dc.subjectINVERNADEROes_ES
dc.subjectSENSORES DE GASESes_ES
dc.subjectRADIO FRECUENCIA (RF)es_ES
dc.subjectTARJETA DE ALMACENAMIENTO (SD)es_ES
dc.titleImplementación de un prototipo electrónico inalámbrico para supervisión, aviso y control de gases contaminantes en invernaderos artesanales.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalVallejo Vizhuete, Henry Ernesto-
Aparece en las colecciones: Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
108T0252.pdf3,23 MBAdobe PDFVista previa