Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/1283
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPachacama Choca, Richard-
dc.contributor.authorChávez Oleas, Natalí Alejandra-
dc.date.accessioned2012-01-09T20:14:23Z-
dc.date.available2012-01-09T20:14:23Z-
dc.date.issued2012-01-09T20:14:23Z-
dc.identifier.citationChávez Oleas, Natalí Alejandra. (2012). Elaboración de un Protocolo de Control de Calidad para el Tomógrafo Digital Computarizado Toshiba Activion TSX-031 A del Area de Imagenología del Hospital Provincial General Docente Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/1283-
dc.descriptionSe desarrolló un Protocolo de Control de Calidad para el Tomógrafo Computarizado (TC) Toshiba Activion TSX-031A del Hospital Provincial General Docente Riobamba, con el fin establecer criterios que contribuyan alcanzar un uso eficiente de las radiaciones ionizantes y permitan la obtención de imágenes diagnósticas de alta calidad con el menor riesgo posible al paciente y al Personal Ocupacionalmente Expuesto. Se utilizó los métodos inductivo para la información y deductivo para el análisis técnico de cada uno de los parámetros del protocolo. Mediante técnicas bibliográficas se recopiló información actual y específica, por medio de técnicas de observación y operación del equipo se obtuvo información técnica acerca del funcionamiento, este protocolo cumple con normativas, nacionales e internacionales como las planteadas por la OIEA, OMS, SCIAN, ICRP, UNSCEAR, también se tomó como referencia protocolos generales para radiodiagnóstico. Este comprende tres partes importantes: el funcionamiento del equipo, la descripción de cada uno de los parámetros físicos, los materiales como fantomas, cámaras de ionización, voltímetros, y el proceso para realizar cada una de las pruebas. Dada la naturaleza de nuestra investigación una primera parte teórica y otra de carácter tecnológico, pues el (TC) es totalmente documentado por el fabricante, esta investigación no tiene necesidad de hipótesis, pero si se ha cumplido con el objetivo general, este protocolo servirá de base para la realización de un programa de garantía de calidad para el área de Imagenología. Se recomienda la utilización inmediata del protocolo, a fin de prevenir accidentes radiológicos y el daño irreparable del equipo.es_ES
dc.description.abstractA Quality Control Protocol was developed for the computed Tomograph (TC) Toshiba. Activion TSX-031A of the Hospital General Docente Riobamba to establish criteria contributing to reaching an efficient use of the ionizing radiations and permi the btainment of high quality diagnosis images with the least possibl risk to the paticnt and ccupationallyexposed personnel. ""The inductive methods were used for information and the deductive ones for the technical analysis of cach protocol parameter. Through the bibliogmphy techniques upxlated and specific information was collected, and through observation techniques and equipment operation technical information bout its functioning was obtained. ""his protocol meets the national and intemational norms such as those put forward by the OIEA, WHO, SCIAN, ICRP and UNSCEAR, general protocols for the radio-diagnosis were also taken as a reference. It compriscs three important parts: the cquipment functioning, the description of the cach physical parameter and material such as fanthoms, “onizaion cameras, oltmetes and the process to cary out cach test Because of the investigation nature there ís fis hcoretical par and a technological one, as the (TC) is totally documented by the manufacturer. This investigation those not need a hypolhesis butt has an accomplished the general objective this protocol will help as the basis forthe realizaion of a quality guarantee program for the Imagenology area. The immediate protocol use ¡s recommended prevent from radiology accidents and the equipenent irreparable damage.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00003-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectRADIACION IONIZANTEes_ES
dc.subjectPREVENCION DE ACCIDENTESes_ES
dc.subjectRADIODIAGNOSTICOes_ES
dc.subjectTOMOGRAFIA COMPUTARIZADAes_ES
dc.subjectIMAGENOLOGIA [Diagnóstico médico]es_ES
dc.subjectPROTOCOLOS DE CONTROL DE CALIDADes_ES
dc.subjectEQUIPO PARA RADIODIAGNOSTICOes_ES
dc.subjectTOMOGRAFOS COMPUTARIZADOSes_ES
dc.subjectPARAMETROS DE FUNCIONALIDAD DE EQUIPOSes_ES
dc.titleElaboración de un Protocolo de Control de Calidad para el Tomógrafo Digital Computarizado Toshiba Activion TSX-031 A del Area de Imagenología del Hospital Provincial General Docente Riobambaes_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalBenalcázar, Freddy-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00003.pdf2,72 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons