Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/13122
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYaulema Garcés, Fausto Manolo-
dc.contributor.authorRamos Parra, Guillermo Andrés-
dc.date.accessioned2019-11-18T16:25:33Z-
dc.date.available2019-11-18T16:25:33Z-
dc.date.issued2019-07-15-
dc.identifier.citationRamos Parra, Guillermo Andrés. (2019). Evaluación de la influencia de distintos niveles de intensidad de corriente en la técnica de electrorremediación para relaves mineros contaminados por Pb y Hg provenientes de Ponce Enríquez, Azuay. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13122-
dc.descriptionEl objetivo de esta investigación fue determinar el mejor tratamiento electrocinetico para remediar relaves mineros contaminados con metales pesados plomo (Pb) y mercurio (Hg) mediante la técnica de electrorremediación. Para este estudio se extrajo muestras de relave minero del sector “La López” ubicado en el cantón Ponce Enríquez provincia del Azuay, se realizó un análisis inicial para conocer las propiedades físicas, físico químicas y mineralógicas. El tratamiento electrocinetico se llevó a cabo utilizando una celda de vidrio con una capacidad de 1200 cm3 para albergar la muestra , la distancia presente entre los electrodos ánodo y cátodo fue de 15 cm, con pozos de 2.5 cm cada uno ,que contenían 95 ml de soluciones electrolíticas como el ácido acético glacial 0.1 M y vinagre blanco, se varió el material de los electrodos alternando entre grafito y acero cromado ,cada tratamiento duró 24 horas y se los sometió a un campo eléctrico con un voltaje constante de 45 V cambiando la intensidad de corriente (1 A y 2 A) ,se trabajó con una muestra de 600g de relave minero acondicionada con una solución humectante de sulfato de hierro 0,1 M. Después de haber realizado los cuatro tratamientos electrocineticos para remediar plomo y mercurio ,se concluyó que, ocupando una intensidad de corriente de 2 A ,con un voltaje constante de 45 V, utilizando grafito como material de los electrodos y ácido acético glacial como solución electrolítica, se puede obtener eficiencias de remoción de 51.52% para plomo y 39.56 % para mercurio, también se verifico luego de análisis de migración iónica que los metales presentes en el sistema tienden a direccionarse a la región anódica. Después de realizar un proceso electrocinetico se recomienda la combinación de técnicas como la fitorremediación para devolverle las propiedades propias de un suelo productivo.es_ES
dc.description.abstractThe goal of this research was to determine the best electro-kinetic treatment to remedy contaminated mine tailings with heavy metals lead (Pb) and Mercury (Hg) by using the electro remediation technique.For this study,mining tailings samples were extracted from "La Lopez" sector located in Ponce Enríquez cantón belonging to Azuay province ,an initial analysis was carried out to know the physical ,chemical and mineralogical properties.The electro-kinetic treatment was conducted using a glass cell with a capacity of 1200 cm3 to hold the sample,the distance between the anode and cathode electrodes was 15 cm ,with wells of 2.5 cm each .containing 95 ml from electrolytic was solutions such as 0.1 M glacial acetic acid and white vinegar ,the electrode material was varied alternating between graphite and chromed steel ,each treatment lasted 24 hours and was subjected to an electric field with a constant voltage of 45 V ,changing current intensity (1 A and 2 A ) ,a 600g sample of mining tailings was worked with ,conditioned with a 0.1 M iron sulfate moisturizer solution. After having performed the four electro kinetic treatments to remedy lead and Mercury ,it was concluded that occupying a current intensity of 2 A ,with a constant voltage of 45 V ,using graphite as electrode material and glacial acetic acid as electrolytic solution,removal efficiencies of 51.52% for lead and 39.56% for mercury can be obtained ,it was also verified after ionic migration analysis that the metals present in the system tend to be directed to the anodic region. After performing an electro-kinetic process ,the combination of techniques such as phytoremediation is recommended to return the real properties of a productive soil.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0451-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOTECNOLOGÍAes_ES
dc.subjectELECTRORREMEDIACIÓNes_ES
dc.subjectMIGRACIÓN IÓNICAes_ES
dc.subjectRELAVE MINEROes_ES
dc.subjectAMPERAJEes_ES
dc.subjectELECTRODOSes_ES
dc.titleEvaluación de la influencia de distintos niveles de intensidad de corriente en la técnica de electrorremediación para relaves mineros contaminados por Pb y Hg provenientes de Ponce Enríquez, Azuay.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCazar Ramírez, Robert Alcídes-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0451.PDF3,48 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons