dc.identifier.citationSánchez Casco, Verónica Paulina.(2019). Rediseño de un sistema de tratamiento de aguas residuales para la curtiduría San Vicente de la ciudad de Ambato. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13807-
dc.descriptionLa curtiduría San Vicente, cuenta con un sistema deficiente de tratamiento de agua residual, es por ello que el siguiente estudio tiene como objetivo rediseñar este sistema de tratamiento mediante un diagnóstico inicial y el respectivo análisis experimental de variables y procesos. Como primera etapa se procedió a evaluar el actual sistema de tratamiento para luego recolectar muestras de las descargas de procesos de pelambre y curtido y realizar su respectivo análisis, se determinó que los principales contaminantes en el agua de pelambre son: DBO5, 12 500 mg/l; DQO, 20 200 mg/L y Sulfuros, 1 620 mg/L mientras que para el agua de curtido se obtuvo los siguientes resultados: Cr6+, 2,10 mg/L; DBO5, 6 240 mg/L y DQO, 12 750 mg/L. Mediante diferentes ensayos de pruebas de tratabilidad se pudo establecer que el tratamiento óptimo para el agua de pelambre es la oxidación de sulfuros mediante un proceso de aireación controlada y utilizando MnSO4 como catalizador, luego de esta primera etapa realizamos un tratamiento químico mediante la adición de coagulante y floculante para finalizar con un proceso de sedimentación que se encargará de separar los lodos contaminantes del agua tratada. En relación al agua de curtido, el sistema de tratamiento inicia con un proceso de estabilización alcalina mediante la adición de cal para lograr un valor de pH de 8,5 para que precipite el cromo, como un hidróxido, luego de esto, se procede a realizar un tratamiento de clarificación mediante un proceso de coagulación-floculación, para finalizar con la sedimentación de lodos y respectiva separación del agua clarificada. Mediante estos procesos se logró obtener un rendimiento superior al 90% en relación a remoción de contaminantes. Finalmente se procedió a realizar el rediseño de la PTAR mediante las respectivas modificaciones del sistema actual y la implementación de nuevos procesos de tratamiento.es_ES
dc.description.abstractThe objective was to redesign a wastewater treatment system for the “San Vicente” tannery located in the city of Ambato. The tannery San Vicente, has a deficient system of wastewater treatment, that is why the following study has as its first stage the current treatment system was assessed and then collected samples of the discharges of liming and tanning processes and to perform their respective analysis, it was determined that the main contaminants in the liming water are: BOD5, 12,500 mg / l; COD, 20 200 mg / L and sulfides, 1 620 mg / L while for the tanning water the following results were obtained: Cr6 +, 2, 10 mg / L; BOD5, 6 240 mg / L and COD, 12 750 mg / L. Through different tests of treatability tests, it was established that the optimal treatment for liming water is the oxidation of sulfides by a controlled aeration process and using MnSO4 as a catalyst, after this first stage we perform a chemical treatment by adding coagulant and flocculants to end with a sedimentation process that will be responsible for separating the contaminating sludge from the treated water. In relation to the tanning water, the treatment system begins with an alkaline stabilization process by adding lime to achieve a pH value of 8.5 so that the chromium precipitates, like a hydroxide, after this, it proceeds to perform a clarification treatment through a coagulation-flocculation process, to end with sludge sedimentation and respective separation of clarified water. Through these processes it was possible to obtain a yield greater than 90% in relation to removal of contaminants. Finally, the redesign of the WWTP was carried out through the respective modifications of the current system and the implementation of new treatment processes.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00572-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectSISTEMA DE TRATAMIENTOes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectCURTIEMBREes_ES
dc.subjectOXIDACIÓN DE SULFUROSes_ES
dc.subjectCLARIFICACIÓNes_ES
dc.titleRediseño de un sistema de tratamiento de aguas residuales para la curtiduría San Vicente de la ciudad de Ambato.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZambrano Vinueza, Mayra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00572.pdf4,38 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons