Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/15961
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVásconez Núñez, Daniela Carina-
dc.contributor.authorSuárez Espinosa, Jhonatan Javier-
dc.date.accessioned2022-06-17T01:17:33Z-
dc.date.available2022-06-17T01:17:33Z-
dc.date.issued2021-06-28-
dc.identifier.citationSuárez Espinosa, Jhonatan Javier. (2021). La bomba de calor como alternativa tecnológica para producción de agua caliente sanitaria. Eficiencia energética del sistema y fuentes de calor. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/15961-
dc.descriptionEl objetivo de la investigación fue analizar a la bomba de calor como alternativa tecnológica para la producción de agua caliente sanitaria, considerando la eficiencia energética del sistema y las fuentes de calor. La investigación contempló cuatro fases. La primera es la determinación de la demanda de agua caliente sanitaria, siendo 140 l/día para una vivienda unifamiliar de 5 personas en la ciudad de Riobamba, la demanda energética (0,95 kW/día) y la potencia del condensador (3,80 kW), utilizando un sistema de acumulación del 30% de capacidad de 80 litros. La segunda fase fue el dimensionamiento de los componentes de la bomba de calor mediante el programa FRIO, obteniendo la potencia de condensación y refrigeración de 2,6 kW y 3,8 kW, respectivamente, para el refrigerante R-134a; el proceso se repitió para varios refrigerantes considerados en el estudio. En la tercera fase se seleccionó el compresor mediante el programa Select 8, escogiéndose el modelo ZH15K4E-PFJ. La cuarta fase fue el cálculo del coeficiente de rendimiento estacionario, en donde el refrigerante que presentó mayor rendimiento fue el propano (R-290) con un coeficiente de 3,82, lo cual se lo considera como una tecnología renovable de acuerdo con la norma EN 16147:2017 con fuente aerotérmica. El refrigerante R-290 tiene un mejor desempeño considerando las condiciones climatológicas de la ciudad de Riobamba, temperatura promedio 12,86 °C con una humedad relativa de 44,2 %.es_ES
dc.description.abstractThis research aimed to analyze the heat pump as a technological alternative for domestic hot water production, considering the energy efficiency of the system and the heat sources. The research included 4 phases: the first was the determination of the domestic hot water demand of 140 l/day for a single-family house of 5 people in the city of Riobamba, energy demand (0.95 kW/day), and condenser power (3.80 kW) using an accumulation system of 30 % capacity of 80 liters. The second phase was the sizing of the heat pump components using the FRIO program, obtaining the condensing and cooling capacity of 2.6 kW and 3.8 kW, respectively, for the refrigerant R-134a; the process was repeated for several refrigerants considered in the study. In the third phase, the compressor was selected using the Select 8 program, and the ZH15K4E-PFJ model was chosen. The fourth phase involved calculating the stationary coefficient of performance where the refrigerant with the highest performance was propane (R-290) with a coefficient of 3.82, which is considered a renewable technology according to the EN 16147:2017 standard with an aerothermal source. The R-290 refrigerant has a better performance considering the climatological conditions of the city of Riobamba, average temperature 12.86 °C with a relative humidity of 44.2 %.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;85T00643-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectBOMBA DE CALORes_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectCOEFICIENTE DE DESEMPEÑO ESTACIONARIOes_ES
dc.subjectREFRIGERANTEes_ES
dc.titleLa bomba de calor como alternativa tecnológica para producción de agua caliente sanitaria. Eficiencia energética del sistema y fuentes de calores_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalTello Oquendo, Fernando Mauricio-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
85T00643.pdf3,32 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons