dc.identifier.citationMoposita Ichina, Luis Hernán. (2021). Diseño de un sistema de tratamiento de aguas residuales para la curtiembre Tenería Nuñez de la parroquia Totoras- Tungurahua. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/16920-
dc.descriptionEL objetivo del presente trabajo de integración curricular es diseñar un sistema de tratamiento de aguas residuales para la Tenería Nuñez, perteneciente a la Parroquia de Totoras-Ambato, se inició con la caracterización de muestras de efluente de pelambre y curtido vegetal encontrándose los parámetros de turbiedad, grasas, sulfuros, DBO5 y DQO para pelambre, turbidez, DBO5, DQO, para curtido vegetal superan el límite máximo permisible que rige el Acuerdo Ministerial 097-A, Anexo de Normativa, Libro VI, Tabla 8. Para elegir el tratamiento más adecuado se determinó el índice de biodegradabilidad, dando como resultado 0,60 para el agua de pelambre, y 0,35 para el agua de curtido vegetal por lo que se puede aplicar tratamiento biológico y fisicoquímico respectivamente; para ello se realizó aireación por un intervalo de tiempo de 16h con adición de Sulfato de Manganeso al 2% con el fin de oxidar sulfuros, coagulación con Cloruro Férrico al 1% (100 ppm), floculante aniónico polielectrolito al 1% (20 ppm) y sedimentación por 1h para pelambre; mientras que, el agua de curtido vegetal se sometió a precipitación con cal-P24, coagulación con PAC al 1 % (100ppm), floculante aniónico polielectrolito al 1% (10 ppm) y sedimentación, permitiendo clarificar el agua. La eficiencia de los ensayos se verificó caracterizando el agua tratada en el que se obtuvo que la mayoría de los parámetros estaban dentro de norma: color, turbiedad, conductividad, grasas, sulfuros, DBO5, DQO para los dos casos. El sistema consta de: dos canales de entrada, rejillas, trampa de grasa, tanque de homogenización, tanque de aireación, tanque sedimentador, lechos de secado y un tanque de almacenamiento de agua tratada. Se recomienda manipular la dosificación de los químicos adecuadamente para un adecuado funcionamiento.es_ES
dc.description.abstractThe aim of this work is to design a wastewater treatment system for Tenería Nuñez, at Totoras Parish, in the city of Ambato. It began with the characterization of effluent samples of fur and vegetable tanning, finding the parameters of turbidity, fats, sulfides, BOD5 and COD for fur, turbidity, BOD5, COD, for vegetable tanning, they exceed the maximum permissible limit that Acuerdo Ministerial 097-A, Anexo de Normativa, Libro VI, Tabla 8 demands. To choose the most appropriate treatment, the biodegradability index was determined, resulting in 0.60 for fur water, and 0.35 for vegetable tanning water, therefore biological and physicochemical treatment can be applied respectively; To achieve this, aeration was carried out for a time range of 16h with the addition of 2% manganese sulfate in order to oxidize sulfides, coagulation with 1% Ferric Chloride (100 ppm), 1% polyelectrolyte anionic flocculant (20 ppm) and sedimentation for 1h for each fur; while, the vegetable tanning water was subjected to precipitation with P24-lime, coagulation with 1% PAC (100ppm), 1% polyelectrolyte anionic flocculant (10ppm) and sedimentation, allowing water to be clarified. The efficiency of the tests was verified by characterizing the treated water in which it was obtained that most of the parameters were within the norm: color, turbidity, conductivity, greases, sulfides, BOD5, COD for both cases. The system consists of: two inlet channels, grids, grease trap, homogenization tank, aeration tank, settling tank, drying beds and a treated water storage tank. It is recommended to manipulate the dosage of chemicals properly for adequate operation.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00751-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectINGENIERÍA QUÍMICAes_ES
dc.subjectPROCESOS INDUSTRIALESes_ES
dc.subjectCURTIEMBREes_ES
dc.subjectCOAGULACIÓNes_ES
dc.subjectFLOCULACIÓNes_ES
dc.subjectSEDIMENTACIÓNes_ES
dc.subjectCARACTERIZACIÓNes_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para la curtiembre Tenería Nuñez de la parroquia Totoras- Tungurahuaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalAndrade Ávalos, Mónica Lilian-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00751.pdf3,74 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons