dc.identifier.citationTixilema Azogue, Edgar Patricio. (2022). Pérdidas energéticas por efecto de las fugas en los sistemas de aire comprimido en función del diámetro del agujero, la presión y el ruido emitido. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/16954-
dc.descriptionEl objetivo de esta investigación, es cuantificar las pérdidas energéticas mediante un banco de pruebas de aire comprimido, con la instalación de tapones testigo en el mismo, para esta experimentación se usan diez diámetros diferentes, simulando fugas de aire comprimido en sistemas industriales. Los datos obtenidos se sometieron a pruebas de normalidad, test de correlación determinado su nivel de correspondencia entre las diferentes variables. Un estudio demuestra que las pérdidas energéticas por fugas de aire comprimido representan el 27,42% de la energía total consumida en el año. En el país, actualmente no existen estudios acerca de eficiencia energética en plantas industriales, lo cual justifica la importancia de este estudio. Se determinó las pérdidas energéticas generadas por cada uno los tapones testigo medidos a través del instrumento Fluke 435 series II cuya unidad en Kilowatts, además del ruido generado con Ultraprobe 15000 con su unidad en Hertz. Se calculó las pérdidas energéticas a través de ecuaciones validando los resultados experimentales. En la cuantificación de las fugas de aire comprimido, se toman datos de ruido generado en decibelios cuyo valor máximo correspondiente al diámetro 1,2 mm es 90,12 Hz con un tiempo 1,25 horas y una energía consumida de 870 kW, además de una mínima correspondiente al diámetro de 0,3 mm es de 73,02 Hz con un tiempo de 7,5 horas y una energía consumida de 361 kW. Se concluye que, al aumentar el diámetro del orificio de la fuga, se generan mayores pérdidas energéticas; así como mayores valores de los decibeles de ruido. Lo que demuestra una correlación alta entre variables del ruido generado con pérdidas energéticas. Se recomienda caracterizar cada uno de los equipos que integran el banco de pruebas, evitando la presencia de fugas en uniones o acoplamientos ya que éstas no provocarían resultados realeses_ES
dc.description.abstractThe objective of this research was to quantify the energy losses by a test bench of compressed air, with the installation of witness plugs in it. For this experimentation, ten different diameters are used, simulating compressed air leaks in industrial systems. The data collected were subjected to normality tests, a correlation test determined the level of correspondence between the different variables. A study shows that energy losses due to compressed air leaks represent 27,42% of the total energy consumed in the year. In the country, there are currently no studies on energy efficiency in industrial plants, which justifies the importance of this study. The energy losses generated by each of the witness plugs measured through Fluke 435 series II instrument whose unit is in Kilowatts. In addition to the noise generated with Ultraprobe 15000 with its unit in Hertz, were determined. The energy losses were calculated through equations validating the experimental results. In the quantification of compressed air leaks, noise data generated in decibels is taken, whose maximum value corresponding to the 1,2 mm diameter is 90,12 Hz with a time of 1,25 hours and an energy consumption of 870 kW. Moreover, a minimum corresponding to the diameter of 0,3 mm is 73,02 Hz with a time of 7,5 hours and an energy consumption of 361 kW. It is concluded that, by increasing the diameter of the leak orifice, greater energy losses are generated; as well as higher values of noise decibels. This shows a high correlation between variables of noise generated with energy losses. It is recommended to characterize each of the equipment that integrate the test bench, avoiding the presence of leaks in joints or couplings since these would not cause real results.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00464-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectSISTEMA DE AIRE COMPRIMIDOes_ES
dc.subjectPÉRDIDA ENERGÉTICAes_ES
dc.subjectBANCO DE PRUEBASes_ES
dc.subjectDECIBELES DE RUIDOes_ES
dc.subjectENERGÍA CONSUMIDAes_ES
dc.titlePérdidas energéticas por efecto de las fugas en los sistemas de aire comprimido en función del diámetro del agujero, la presión y el ruido emitidoes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalCalderón Freire, Edisson Fernando-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00464.pdf2,69 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons