Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/17687
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorZambrano Vinueza, Mayra Paola-
dc.contributor.authorBarriga Morales, Heidy Mabela-
dc.date.accessioned2022-10-24T20:20:44Z-
dc.date.available2022-10-24T20:20:44Z-
dc.date.issued2022-04-14-
dc.identifier.citationBarriga Morales, Heidy Mabela. (2022). Diseño de una planta de tratamiento de aguas residuales para la industria láctea “PLADELACT” ubicada en la comunidad de Utuñag. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/17687-
dc.descriptionEl objetivo del presente trabajo de integración curricular consistió en diseñar una planta de tratamiento de aguas residuales para la industria Planta de Lácteos (PLADELACT) ubicada en la comunidad de Utuñag, cantón Penipe, en concordancia con la norma general para la descarga de efluentes al sistema de alcantarillado público, del libro VI del Texto Unificado de Legislación Ambiental Secundaria del Ministerio del Medio Ambiente (TULSMA), ANEXO 1, TABLA 8. Para ello, se partió de la caracterización físico-química y microbiológica inicial de los efluentes generados por dicha industria, con la finalidad de conocer los valores de turbiedad (825 NTU), pH (4.78), cloruros (1180 mg/l), aceites y grasas (102.0 mg/l), DQO (13450 mg/l), DBO5 (9120 mg/l), sólidos totales (18250 mg/l), etc. Estos resultados mostraron valores de los parámetros fuera de los límites permisibles en la referida norma, dando lugar al desarrollo de pruebas de tratabilidad de las aguas residuales utilizando el test de jarras y técnicas de aeración y filtración, con el objetivo de disminuir la cantidad de contaminantes. De esta manera, se realizaron los cálculos de ingeniería para el diseño y dimensionamiento de una planta de tratamiento que consta de una trampa de aceites y grasas, un tanque Imhoff para sedimentación, una primera etapa de aeración, una etapa de coagulación y floculación, una segunda etapa de aeración, y finalmente una etapa de filtración. Luego de tratar las aguas residuales con esta planta, se llevó a cabo la caracterización final de las aguas resultantes, obteniéndose valores de los parámetros dentro de la norma, así: turbiedad (2.8 NTU), pH (7.38), cloruros (780 mg/l), aceites y grasas (10.4 mg/l), DQO (492 mg/l), DBO5 (187 mg/l), sólidos totales (980 mg/l), etc. Consecuentemente, estos resultados validaron el diseño propuesto. Se recomienda que la empresa cuente con un procedimiento de sedimentación cerrado y aislado de contaminantes.es_ES
dc.description.abstractThe objective of this curricular integration work consisted of designing a wastewater treatment plant for the Dairy Plant (PLADELACT) industry located in the community of Utuñag, Penipe canton, in accordance with the general regulations for the discharge of effluents into the public sewage system, in Book VI of the Unified Text of Secondary Environmental Legislation of the Ministry of the Environment (TULSMA), ANNEX 1, TABLE 8. For this purpose, the initial physical-chemical and microbiological characterization of the effluents generated by this industry was a starting point, in order to determine the values of turbidity (825 NTU), pH (4.78), chlorides (1180 mg/l), oils and greases (102.0 mg/l), COD (13450 mg/l), BOD5 (9120 mg/l), total solids (18250 mg/l), etc. These results showed values of the parameters outside the permissible limits in the aforementioned standard, leading to the development of wastewater treatability tests using the jar test and aeration and filtration techniques, with the aim of reducing the amount of pollutants. In this way, engineering calculations were made for the design and sizing of a treatment plant consisting of an oil and grease trap, an Imhoff tank for sedimentation, a first aeration stage, a coagulation and flocculation stage, a second aeration stage, and finally a filtration stage. After treating the wastewater with this plant, the final characterization of the resulting water was carried out, yielding values of the parameters within the standard, as follows: turbidity (2.8 NTU), pH (7.38), chlorides (780 mg/l), oils and fats (10.4 mg/l), COD (492 mg/l), BOD5 (187 mg/l), total solids (980 mg/l), etc. Consequently, these results validated the proposed design. The company is recommended to have a closed, pollutant-isolated sedimentation procedure.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00770-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectINGENIERÍA QUÍMICAes_ES
dc.subjectPLANTA DE TRATAMIENTOes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectEFLUENTES INDUSTRIALESes_ES
dc.subjectCONTAMINACIÓN AMBIENTALes_ES
dc.subjectINDUSTRIA LÁCTEAes_ES
dc.titleDiseño de una planta de tratamiento de aguas residuales para la industria Láctea “PLADELACT” ubicada en la comunidad de Utuñages_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalPuente Guijarro, César Arturo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00770.pdf2,93 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons