Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/17779
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGarcía Mora, Félix Antonio-
dc.contributor.authorCharanchi Saltos, Javier Amador-
dc.date.accessioned2022-11-08T17:23:44Z-
dc.date.available2022-11-08T17:23:44Z-
dc.date.issued2022-06-07-
dc.identifier.citationCharanchi Saltos, Javier Amador. (2022). Análisis de eficiencia energética en edificios residenciales utilizando aprendizaje de máquinas basado en regresión lineal. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/17779-
dc.descriptionEl presente trabajo de integración curricular tuvo como objetivo principal aplicar técnicas de análisis de aprendizaje automático (ML) basado en métodos de regresión para predecir las cargas de calefacción y refrigeración en edificios residenciales, a través de la generación de ecuaciones de regresión y código en lenguaje de Python para las técnicas de ML. Por lo que, para la creación del algoritmo de aprendizaje se utilizó un data set de rendimiento energético cuya base de datos fue extraída del Machine Learning Repository de la Universidad de California, Irvine, este conjunto de datos contiene ocho atributos (o características, denotados por X1 a X8) y dos respuestas (o resultados, denotados por Y1 y Y2) cuya finalidad es utilizar las ocho funciones para predecir cada una de las dos respuestas. La primera parte del trabajo está dedicada al análisis exploratorio de datos y visualizaciones, así como a la aplicación de técnicas estadísticas y análisis de componentes principales del data set. Luego de este análisis en una segunda parte, se desarrollaron varios métodos de regresión, donde se comparó los rendimientos de cada algoritmo, con el objetivo de encontrar el modelo más óptimo para predecir la eficiencia energética en los edificios residenciales, por último se evaluaron los diferentes algoritmos de regresión, analizando los resultados, la precisión y los errores que arrojaron estos, donde se determinó que los modelos de Random Forest Regression, Decision Tree Regressor, Extra Tree Regressor y el modelo de regresión lineal son modelos aplicables a la predicción del valor de la carga de calefacción y refrigeración, debido a que los cuatro modelos muestran precisiones mayores al 90%, siendo el modelo de Random forest el más adecuado para este estudio por dar una precisión del 98%, Se recomienda realizar otros modelos de ML con la finalidad de mejorar los resultados de las predicciones.es_ES
dc.description.abstractThe objective of this curricular integration work was to apply automatic learning analysis techniques (ML). It was based on regression methods to predict heating and cooling loads in residential buildings, through the generation of regression equations and Python language code for ML techniques. Therefore, for the creation of the learning algorithm, an energy performance data set was used whose database was extracted from the Machine Learning Repository of California University, Irvine. This data set contains eight attributes (or characteristics, denoted by X1 through X8) and two responses (or outcomes, denoted Y1 and Y2) whose purpose is to use the eight functions to predict each of the two responses. The first part of the work is dedicated to the exploratory analysis of data and visualizations, as well as the application of statistical techniques and analysis of the main components of the data set. After this analysis in a second part, several regression methods were developed, where the performance of each algorithm was compared, with the aim of finding the most optimal model to predict energy efficiency in residential buildings. Finally the different regression algorithms, analyzing the results, the precision and the errors that these showed. The Random Forest Regression, Decision Tree Regressor, Extra Tree Regressor and the linear regression model were determined that are models applicable to the prediction of the value of the heating and cooling load. Because, the four models show accuracies greater than 90%, the Random forest model being the most suitable for this study as it gives an accuracy of 98%. It is recommended to carry out other ML models with the purpose to improve the prediction results.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00479-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectINTELIGENCIA ARTIFICIALes_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectREGRESIÓN LINEALes_ES
dc.subjectEDIFICIOS RESIDENCIALESes_ES
dc.subjectAPRENDIZAJE DE MÁQUINASes_ES
dc.titleAnálisis de eficiencia energética en edificios residenciales utilizando aprendizaje de máquinas basado en regresión lineales_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalHernández Dávila, Eduardo Segundo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00479.pdf3,71 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons