dc.identifier.citationCocha Telenchana, Laura Susana. (2010). Análisis de la Concentración de Contaminantes SO2 y BTX Usando Sensores Pasivos. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/238-
dc.descriptionSe analizaron los contaminantes SO2, NO2 y BTX, empleando sensores pasivos con el afán de conocer los niveles de contaminación del aire y obtener datos necesarios para la implementación definitiva de una red de monitoreo atmosférico, la cual servirá al Ilustre Municipio de Riobamba para tomar las acciones pertinentes y buscar reducir la contaminación ambiental. Las mediciones se las efectúo en el período Febrero 2008 - Abril 2009. Se instalaron seis puntos estratégicos como estaciones en los sectores de (AME) Norte, (La Merced) Centro, (EMAPAR) Sur de la Ciudad de Riobamba, Gatazo, Guano y Penipe, cubriendo el centro de la ciudad, sectores industriales, comerciales, de gran densidad de tráfico y sectores afectados directamente por actividad volcánica del Tungurahua. El Método es experimental y la técnica pasiva de monitoreo de calidad de aire. El registro de concentración de contaminantes fueron analizados cualitativa y cuantitativamente. Registrando una concentración de NO2 (12,75µg/m3), SO2 (7,18µg/m3), benceno (7,93µg/m3), tolueno (12,01µg/m3) y xilenos (1,35µg/m3), valores que no superan los límites establecidos en la Norma Ecuatoriana ni en las Guías de Calidad del Aire de la OMS, en el caso de Benceno no supera la norma anual del estado de California - Estados Unidos, pero supera la Norma Europea. El análisis realizado con sensores pasivos, permitió conocer los niveles de concentración de contaminación de SO2, NO2 y BTX, valores significativos comparados con los reportados en el Distrito Metropolitano de Quito, a pesar de que Riobamba tiene un parque automotor, densidad poblacional y actividad industrial inferior que Quito, por lo que se recomienda al Ilustre Municipio de Riobamba continúe con estudios y análisis de contaminación atmosférica para prevenir potenciales peligros para la salud de sus habitantes.es_ES
dc.description.abstractThe pollutants SO2, NO2 and BTX were analyzed, using passive sensors in order to know the levels of air pollution and obtain data necessary for the final implementation of an atmospheric monitoring network, which will serve the Municipality of Riobamba to take appropriate actions and seek to reduce environmental pollution. The measurements were taken during the period February 2008 - April 2009. Six strategic points were installed as stations in the sectors of (AME) North, (La Merced) Center, (EMAPAR) South of the city of Riobamba, Gatazo, Guano and Penipe, covering the center of the city, industrial, commercial, high traffic density and sectors directly affected by volcanic activity of Tungurahua. The method is experimental and the air quality monitoring technique is passive. The pollutant concentration records were analyzed qualitatively and quantitatively. The concentration of NO2 (12.75µg/m3), SO2 (7.18µg/m3), benzene (7.93µg/m3), toluene (12.01µg/m3) and xylenes (1.35µg/m3), values that do not exceed the limits established in the Ecuadorian Standard or in the WHO Air Quality Guidelines. In the case of benzene, it does not exceed the annual standard of the state of California - United States, but exceeds the European Standard. The analysis carried out with passive sensors revealed the concentration levels of SO2, NO2 and BTX pollution, significant values compared to those reported in the Metropolitan District of Quito, despite the fact that Riobamba has a smaller vehicle fleet, population density and industrial activity than Quito; therefore, it is recommended that the Municipality of Riobamba continue with studies and analysis of air pollution to prevent potential health hazards for its inhabitants.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0025-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectCONCENTRACIÓN DE CONTAMINANTESes_ES
dc.subjectRIOBAMBA [CANTÓN]es_ES
dc.subjectCONTAMINACIÓN ATMOSFÉRICAes_ES
dc.subjectANÁLISIS AMBIENTALes_ES
dc.subjectSENSORESes_ES
dc.subjectTRÁFICO VEHÍCULARes_ES
dc.subjectVOLCÁN TUNGURAHUAes_ES
dc.subjectDIÓXIDO DE NITRÓGENOes_ES
dc.subjectDIÓXIDO DE AZUFREes_ES
dc.subjectDIÓXIDO DE BENCENOes_ES
dc.titleAnálisis de la Concentración de Contaminantes SO2 y BTX Usando Sensores Pasivoses_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCazar, Robert-
dc.contributor.miembrotribunalRecalde, Celso-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0025.pdf1,56 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons