Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/2697
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorÁvalos, César-
dc.contributor.authorParedes Salán, Mariela Cristina-
dc.date.accessioned2013-08-28T16:31:46Z-
dc.date.available2013-08-28T16:31:46Z-
dc.date.issued2013-08-28T16:31:46Z-
dc.identifier.citationParedes Salán, Mariela Cristina. (2013). Diseño de la planta de tratamiento para aguas residuales de la lavandería y tintorería Jav - Tex del Cantón Pelileo. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/2697-
dc.descriptionSe diseñó la planta de tratamiento para aguas residuales de Lavandería y Tintorería JAV - TEX del cantón Pelileo, para aguas provenientes de los procesos de lavado y tinturado. Mediante el método experimental, se empezó por el reconocimiento de los procesos desarrollados en la planta, y posteriormente realizar un diagnóstico, donde se tomó muestras y datos, para esto necesitamos de recipientes, termómetro y cronómetro, con el método deductivo partimos del diseño y terminamos describiendo cada etapa del tratamiento. Al caracterizar el agua residual proveniente de las etapas de Lavandería y Tintorería JAV-TEX, los resultados fueron, 1200 mg/L de Demanda Química de Oxígeno, 703 mg/L de Demanda Bioquímica de Oxígeno, 2 ml/L Sólidos Sedimentales, 224 de Sólidos en suspensión, 244 Unidad Nefelométrica De Turbidez, 0,030 mg/L Fenoles, 1,50 mg/L Tensoactivos, que fueron analizados y tratados con el fin de disminuir la contaminación, porque no cumple con los límites de descarga establecidos en el Texto Unificado de Legislación Ambiental. Se concluye que los parámetros analizados permitieron determinar los componentes de la planta de tratamiento, el mismo que constará de: rejillas, tanque homogeneizador, agitador de paletas, tanque sedimentador, para tener un efluente que cumpla con los parámetros de acuerdo a los límites establecidos, por la normativa vigente. Recomiendo a la empresa tener en cuenta los estudios con respecto al ambiente que se han realizado, e implementar la planta de tratamiento, para así disminuir la contaminación que se está generando, y posteriormente hacer análisis frecuentes para verificar que el tratamiento esté marchando bien.es_ES
dc.description.abstractA wastewater treatment plant was designed for the JAV - TEX laundry and dyeing plant in the Pelileo canton, for water from the washing and dyeing processes. Using the experimental method, we started with the recognition of the processes developed in the plant, and then made a diagnosis, where samples and data were taken, for this we needed containers, thermometer and stopwatch, with the deductive method we started from the design and ended by describing each stage of treatment. When characterizing the wastewater from the JAV-TEX Laundry and Dry Cleaning stages, the results were 1200 mg/L of Chemical Oxygen Demand, 703 mg/L of Biochemical Oxygen Demand, 2 ml/L of Sediment Solids, 224 of Suspended Solids, and 244 Nephelometric Unit, 244 Nephelometric Turbidity Unit, 0.030 mg/L Phenols, 1.50 mg/L Surfactants, which were analyzed and treated in order to reduce contamination, because they do not comply with the discharge limits established in the Unified Text of Environmental Legislation. It is concluded that the analyzed parameters allowed to determine the components of the treatment plant, which will consist of: grids, homogenizing tank, paddle agitator, settling tank, to have an effluent that meets the parameters according to the limits established by current regulations. I recommend that the company take into account the environmental studies that have been carried out and implement the treatment plant in order to reduce the contamination that is being generated, and then carry out frequent analyses to verify that the treatment is working properly.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00215-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectPELILEO [CANTÓN]es_ES
dc.subjectTINTORERIAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectDISEÑO DE PLANTAS DE TRATAMIENTO DE AGUAes_ES
dc.subjectPLANTAS DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectLAVANDERIASes_ES
dc.titleDiseño de la planta de tratamiento para aguas residuales de la lavandería y tintorería Jav - Tex del Cantón Pelileoes_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalLeón, Gerardo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a