Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/3116
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorEcheverría, Magdy-
dc.contributor.authorGrefa Vegay, Luis Gustavo-
dc.date.accessioned2014-02-06T00:01:19Z-
dc.date.available2014-02-06T00:01:19Z-
dc.date.issued2014-02-06T00:01:19Z-
dc.identifier.citationGrefa Vegay, Luis Gustavo. (2014). Rediseño de la planta de tratamiento de aguas residuales - Centro de Faenamiento Municipal de Ganado de Orellana. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3116-
dc.descriptionLa presente investigación de rediseño se realizó en la Planta de Tratamiento de Aguas Residuales del Centro de Faenamiento Municipal de Francisco de Orellana, Provincia de Orellana. Para el cual se utilizó el método analítico, que determinaron las variables que se consideran de importancia para el análisis del agua residual del sistema de tratamiento, dando a conocer las condiciones físicas-químicas-biológicas del agua tratada en la planta. Los análisis respectivo fueron realizados en el Laboratorio de Suelos, Aguas y Planta (LABSU), utilizando técnicas y material de laboratorio basados en métodos Normalizados APHA,AWWA,WPCF 17 ed. Mediante un plan de muestreo se cogió las muestras de agua residual, usando botellas de vidrio ámbar, frascos estériles, guantes y mascarilla. Los resultados de laboratorio indican que la concentración de la demanda química de oxígeno (350,87 mg/L), hierro total (12,46 mg/L), sólidos totales suspendidos (128,17 mg/L), sólidos sedimentables (2,33 mg/L), color real (516,5 PtCo) y coliformes fecales (2,01x106 Col/100ml) no garantizan la calidad del agua de acuerdo a lo establecido en el TULSMA. El rediseño implicara dos procesos de mejora: el primero corresponde el dimensionamiento de un sistema de rejilla fina (0,51m*0,40m), con 17 barras metálicas, 0,9cm de espesor y una separación entre ellas de 1,5 cm; y la segunda consiste en el cambio del material filtrante del primer humedal una capa de 30 cm de grava de 5mm diámetro, la segunda y tercera capa de 20 cm de grava de 15 y 25 mm de diámetro respectivamente, y el segundo humedal una capa de 40 cm de arena, la segunda y tercera capa de 15cm de grava de 15 y 25 mm de diámetro respectivamente. El rediseño es de gran importancia ya que permitirá descargar un efluente de buena calidad (río Chambira), el cual cumpla con los límites de descarga a un cuerpo de agua dulce, establecido en la normativa ambiental ecuatoriana vigente. Se recomienda a la Municipalidad mantener el control de la calidad.es_ES
dc.description.abstractThe present redesign research was carried out at the Wastewater Treatment Plant of the Municipal Slaughtering Center of Francisco de Orellana, Orellana Province. For which the analytical method was used, which determined the variables considered important for the analysis of the wastewater from the treatment system, revealing the physical-chemical-biological conditions of the water treated in the plant. The respective analyses were carried out at the Soil, Water and Plant Laboratory (LABSU), using laboratory techniques and materials based on APHA, AWWA and WPCF 17 ed. standard methods. Laboratory results indicate that the concentration of chemical oxygen demand (350.87 mg/L), total iron (12.46 mg/L), total suspended solids (128.17 mg/L), settleable solids (2.33 mg/L), true color (516.5 PtCo) and fecal coliforms (2.01x106 Col/100ml) do not guarantee water quality according to TULSMA. The redesign will involve two improvement processes: the first corresponds to the sizing of a fine grid system (0.51m*0.40m), with 17 metal bars, 0.9cm thick and a separation between them of 1.5 cm; and the second consists of changing the filtering material of the first wetland, a layer of 30 cm of gravel of 5mm diameter, the second and third layers of 20 cm of gravel of 15 and 25 mm diameter respectively, and the second wetland, a layer of 40 cm of sand, the second and third layers of 15 cm of gravel of 15 and 25 mm diameter respectively. The redesign is of great importance because it will allow the discharge of a good quality effluent (Chambira River), which complies with the limits for discharge into a freshwater body, as established in current Ecuadorian environmental regulations. It is recommended that the municipality maintain quality control.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0080-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectSISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectPROVINCIA DE ORELLANAes_ES
dc.subjectPLANTA DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectREDISEÑOes_ES
dc.subjectEMPRESA MUNICIPAL DE FAENAMIENTO DE GANADOes_ES
dc.titleRediseño de la planta de tratamiento de aguas residuales - Centro de Faenamiento Municipal de Ganado de Orellanaes_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalWayllas, Pablo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0080.pdf6,05 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons