dc.identifier.citationEspin Saltos, Alejandra Cecilia. (2014). Diseño de un sistema de tratamiento de aguas residuales para el camal municipal del cantón Alausí. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3204-
dc.descriptionEn la presente investigación se diseñó de un Sistema de Tratamiento de Aguas Residuales para el Camal Municipal del Cantón Alausí. Mediante el método deductivo, el estudio empezó por el reconocimiento del lugar de recolección y descarga del agua residual, luego se realizó la determinación del caudal del efluente mediante el método volumétrico manual con la utilización de un balde graduado, una cuerda y un cronómetro, de donde se obtuvo muestras representativas y datos para la realización del diseño de la planta. Al caracterizar el agua residual se obtuvo los resultados de los análisis físicos químicos y microbiológicos teniendo así: DBO5 2885 mg/L, DQO 4590 mg/L, sólidos totales 9213,33 mg/L, sólidos suspendidos 514 mg /L, turbiedad 406,33 UNT, coliformes totales 12654000 UFC/100 ml, coliformes fecales 92012000 UFC/100 ml, los parámetros mencionados se encuentran fuera de los límites permisibles de las normas del Texto Unificado de Legislación Ambiental. Teniendo después del tratamiento valores los siguientes valores: DBO5 204 mg/L, DQO 314 mg/L, sólidos totales 1164 mg/L, sólidos suspendidos 24 mg /L, turbiedad 3,45 UNT, coliformes totales 70400 UFC/100 ml, coliformes fecales 4840 UFC/100 ml con valores menores a los de la norma de Texto Unificado de Legislación Ambiental. Se concluye que los parámetros analizados permitieron determinar los componentes del sistema de tratamiento el cual está formado de: rejillas, un tanque circular sedimentador primario, un tanque de aireación y finalmente un tanque de floculación, para que el efluente cumpla con los límites establecidos por la norma del Texto unificado de Legislación Ambiental. Recomiendo al Ilustre Municipio del Cantón Alausí, implementar la planta de tratamiento para el manejo y control de la contaminación de los efluentes líquidos descargados al alcantarillado público por el camal.es_ES
dc.description.abstractIn the present investigation, a Wastewater Treatment System was designed for the Municipal Camal of Alausí Canton. Using the deductive method, the study began with the recognition of the place of collection and discharge of wastewater, then the determination of the effluent flow was carried out using the manual volumetric method with the use of a graduated bucket, a rope and a stopwatch, from which representative samples and data were obtained for the design of the plant. When characterizing the wastewater, the results of the physical, chemical and microbiological analyses were obtained as follows: BOD5 2885 mg/L, COD 4590 mg/L, total solids 9213.33 mg/L, suspended solids 514 mg/L, turbidity 406.33 UNT, total coliforms 12654000 CFU/100 ml, fecal coliforms 92012000 CFU/100 ml, the parameters mentioned are outside the permissible limits of the standards of the Unified Text of Environmental Legislation. After treatment, the following values were obtained: BOD5 204 mg/L, COD 314 mg/L, total solids 1164 mg/L, suspended solids 24 mg/L, turbidity 3.45 UNT, total coliforms 70400 CFU/100 ml, fecal coliforms 4840 CFU/100 ml with values lower than those of the Unified Text of Environmental Legislation. It is concluded that the parameters analyzed allowed determining the components of the treatment system, which consists of: grids, a circular primary sedimentation tank, an aeration tank and finally a flocculation tank, so that the effluent complies with the limits established by the standard of the Unified Text of Environmental Legislation. I recommend that the Municipality of Alausí Canton implement the treatment plant to manage and control the contamination of liquid effluents discharged into the public sewage system by the animal feedlot.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00238-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectSISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectPROVINCIA DE CHIMBORAZOes_ES
dc.subjectDISEÑO DE SISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectCAMAL MUNICIPAL DEL CANTÓN ALAUSÍes_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para el camal municipal del cantón Alausíes_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalRivera, María Fernanda-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00238.pdf4,42 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons