Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/3662
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVillacrés Alvarez, Mario Gustavo-
dc.contributor.authorNúñez Falconí, Ángel Roberto-
dc.date.accessioned2015-01-06T15:14:14Z-
dc.date.available2015-01-06T15:14:14Z-
dc.date.issued2014-
dc.identifier.citationNúñez Falconí, Ángel Roberto. (2014). Diseño de un sistema de tratamiento de agua potable en las comunidades Pichán Central, Chocaví Chico y Chocaví Central de la parroquia San Isidro de Patulú. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3662-
dc.descriptionSe diseñó un sistema de tratamiento para la potabilización del agua en las comunidades Pichán Central, Chocaví Chico y Chocaví Central de la Parroquia de San Isidro de Patulú, Cantón guano, Provincia de Chimborazo para obtener agua potable de calidad que mejore las Condiciones de vida de los habitantes de las mencionadas comunidades. Se tomaron cuatro muestras de agua en la captación en el transcurso de 1 mes para la caracterización físico – química y microbiológica, los análisis se llevaron a cabo en el laboratorio de Análisis Técnicos de la Facultad de Ciencias de la ESPOCH, identificando que los parámetros se encontraban fuera de los límites máximos permitidos por la Norma Técnica Ecuatoriana INEN 1108:2011. Siendo estos: color 198 Unid. (Pt-Co); turbiedad 19,8 NTU; hierro 2,824 mg/l; coliformes totales: 8 UFC/100 ml y coliformes fecales: 3 UFC/100 ml. Conforme a esta caracterización efectuada se determinó la necesidad de diseñar un sistema de tratamiento, que permita reducir los valores de los parámetros descritos para dar cumplimiento al reglamento de la norma establecida; el diseño consta de 5 etapas: mezcla rápida en vertedero rectangular, floculación utilizando policloruro de aluminio, sedimentación laminar, filtración y finalmente desinfección. Posterior a la aplicación del sistema de tratamiento de potabilización se caracterizó al agua tratada, obteniéndose los siguientes resultados; color: 8 Unid. (Pt-Co); turbiedad 2 NTU; hierro 0,05 mg/l; coliformes totales: 0 UFC/100 ml y coliformes fecales: 0 UFC/100 ml. Notando que los mismos cumplen con los límites establecidos por la norma. Se concluye que los parámetros analizados permitieron determinar los componentes de la planta de tratamiento para que la misma tenga una alta eficiencia en la potabilización del agua consiguiendo que sea apta para el consumo humano. Se recomienda implementar el sistema de tratamiento para garantizar agua potable de calidad que preserve la salud y contribuya al desarrollo humano y económico de los habitantes mediante el abastecimiento del líquido vital.es_ES
dc.description.abstractIt was designed a treatment system for water potabilisation at the communities Pichan Central, Chocavi Chico and Chocavi Central from San Isidro de Patulu Parish, Guano canton, Chimborazo province, in order to get quality fresh water to improve life conditions of the inhabitants there. Four samples of water were taken in the pond along one month for the physicalchemical and microbiological characterization, the analysis were carried out at the laboratory of Technical analysis of the Faculty of Science at ESPOCH, having been found that the parameters were beyond of the maximum limits allowed by the Ecuadorian Technical Norm INEN 1108: 2011. The results are: color 198 units. (Pt- Co); blur 19,8 NTU; Iron 2,824 mg/l; total coliforms: 8 UFC/100 ml and fecal coliforms: 3 UFC/100 ml. According to this characterization, it was determinated that the need to design a treatment system which allow to reduce the rate of these parameters and so, to accomplish with the regulation of the norm; the design has 5 stages: a brief mixture of the rectangular bowl, flocculation by means of the use of polichlorine of aluminum, layer sedimentation, filtration and finally desinfection. After the application of the potabilisation system, the treated water was characterized, having as a result; color 8 units. (Pt-Co); blur 2 NTU; Iron 0,05 mg/l; total coliforms: 0 UFC/100 ml and fecal coliforms: 0 UFC/100 ml. So they respond to the limits set in the norm. In short, the parameters analyzed allowed to determine the components of the treatment plant so it has high efficiency in the potabilisation of water and for instance, safe for human consumption. It is recommended to implement the treatment system in order to guarantee quality fresh water which preserves health and help to human and economic development of the inhabitants through water supply.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00277-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectAGUA POTABLEes_ES
dc.subjectANÁLISIS FÍSICO-QUÍMICO DEL AGUAes_ES
dc.subjectCHIMBORAZO (PROVINCIA)es_ES
dc.subjectSISTEMA DE TRATAMIENTO DE AGUAes_ES
dc.subjectSAN ISIDRO DE PATULÚ (PARROQUIA)es_ES
dc.subjectGUANO (CANTÓN)es_ES
dc.titleDiseño de un sistema de tratamiento de agua potable en las comunidades Pichán Central, Chocaví Chico y Chocaví Central de la parroquia San Isidro de Patulú.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCalderón, Segundo Hugo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00277 UDCTFC.pdf5,22 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons