Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4571
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorFiallos Velasco, Pablo javier-
dc.contributor.authorGonzález Luna, Byron Vinicio-
dc.contributor.authorQuispe Saca, Roberto Carlos-
dc.date.accessioned2016-03-24T17:15:47Z-
dc.date.available2016-03-24T17:15:47Z-
dc.date.issued2016-03-24-
dc.identifier.citationGonzález Luna, Byron Vinicio; Quispe Saca, Roberto Carlos. (2016). Comparación de la efectividad de las técnicas de ultrasonido pasivo y análisis de vibraciones en la detección de fallas incipientes en rodamientos. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4571-
dc.descriptionLa presente investigación describe la comparación entre la efectividad de la técnica de ultrasonido pasivo y análisis de vibraciones en la detección de fallas incipientes en rodamientos. Para ello se construyó un módulo didáctico para analizar, en el cual se realizaron varias desalineaciones angulares, controladas desde 5,2 hasta 22,7 mrad en intervalos de 5,2 mrad, durante cuatro horas de funcionamiento que corresponde al 100% del tiempo total que duro el ensayo para cada intervalo de desalineación a una velocidad de rotación del eje de 3750 rpm. En la toma de datos de vibraciones se utilizó el equipo Vibrachek 200, con su respectivo acelerómetro para capturar el espectro, tanto en las posiciones radial y axial (ISO 10816-1,1995).Para el análisis se utilizó el espectro envolvente de aceleración dispuesto en la norma, la cual permite filtrar señales de vibración de alta frecuencia, de igual manera se usó un transductor magnético para la toma de datos de ultrasonido pasivo mediante el equipo Ultraprobe 15000. Tras el análisis de los datos se concluyó que el análisis por ultrasonido pasivo es más efectivo que el análisis de vibraciones en la detección de fallas incipientes en rodamientos, debido a que la primera técnica permite visualizar cambios que se manifiestan en los componentes del rodamiento a altas frecuencias, sin dejar de lado al análisis de vibraciones el cual nos permite observar en el espectro las diferentes etapas que se producen durante la evolución de una falla incipiente en un rodamiento. Se recomienda en el caso de realizar monitoreo con el equipo de ultrasonido, recordar realizar las mediciones con los mismos parámetros de funcionamiento con los cuales se realizó la medida de línea base, para de esta manera obtener un análisis más exacto de las condiciones del activo a monitorear. Con este propósito, el presente trabajo de titulación se lo realizo bajo las líneas de investigación de la ESPOCH-2012; ARTICULO 5, para así contribuir con el sostenimiento del plan nacional del buen vivir e indirectamente con la nueva matriz productiva y energética del país.es_ES
dc.description.abstractThis paper describes the comparison between the effectiveness of the technique of passive ultrasound and vibration analysis in detecting incipient bearing failure. For this analysis a training module was build where several angular, controlled from 5,2 to 22,7 mrad were performed at intervals of 5,2 mrad for 4 hour of operation corresponding to 100% of the total duration of the test for each interval to a misalignment of the shaft rotation speed 3750 rpm. The Vibrachek 200 equipment was used, with its respective accelerometer data collection to capture the vibration spectrum in both radial and axial positions (ISO 10816-1, 1995). To analyze the spectrum envelope willing acceleration was used in the standard, which allows to filters signal of high frequency vibration; just as a magnetic for passive data collection using the Ultraprobe 15000 ultrasound transducer equipment was used. After analyzing the data it was concluded that the passive analysis is more effective than ultrasonic vibration analysis in detecting incipient bearing failure, because the first technique to visualize changes that occur in the components of the bearings at high frequencies, without neglecting vibration analysis which allows us to observe spectrum different stages that occur during the development of an incipient failure of a bearing. It is recommended, in the case of performing monitoring with ultrasound equipment; remember to measure with the same operating parameters with which the baseline measurement was performed, to thereby obtain a more accurate analysis of conditions active monitor. For this purpose, the present researching works was made based on the investigation guidelines of ESPOCH-2012; ARTICLE V, thus contributing to the sustainability of the Plan Nacional del Buen Vivir and indirectly with the new production and energy matrix of the country.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00267-
dc.subjectULTRASONIDOes_ES
dc.subjectANÁLISIS VIBRACIONALes_ES
dc.subjectDETECCIÓN DE FALLASes_ES
dc.subjectRODAMIENTOSes_ES
dc.subjectSISTEMA DE TRANSMISIÓNes_ES
dc.subjectSISTEMA ELÉCTRICOes_ES
dc.titleComparación de la efectividad de las técnicas de ultrasonido pasivo y análisis de vibraciones en la detección de fallas incipientes en rodamientos.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalHernández Dávila, Eduardo Segundo-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00267.pdf4,55 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.