dc.identifier.citationDelgado Ruíz, Ligia Margarita. (2015). Optimización del Sistema de Tratamiento de Agua Potable de la ciudad de Echeandía – provincia Bolívar. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4791-
dc.descriptionEl presente trabajo de investigación se realizó la Optimización del Sistema de Tratamiento de Agua Potable en la planta de San Vicente Alto, perteneciente a la Ciudad de Echeandía, Provincia Bolívar. Con el método deductivo e inductivo: se diagnosticó los problemas ocasionados en la calidad del agua, y con el método experimental se procedió a realizar la caracterización físico-químicos y microbiológicos del agua a la entrada y salida de la planta de tratamiento en diferentes condiciones climáticas, en el laboratorio de Análisis Técnico de la Facultad de Ciencias de la ESPOCH, luego de la caracterización del agua se determinaron los parámetros fuera de los límites permisibles de acuerdo a la Norma INEN 1108:2011 “Agua Potable. Requisitos”, siendo color, turbiedad, nitritos y fosfatos específicamente en época de lluvia, para la remoción de éstos parámetros se procedió a realizar pruebas de tratabilidad con Sulfato de Aluminio y Policloruro de Aluminio, llegando a encontrar la dosificación adecuada de 21,34 kg por día con el Policloruro de Aluminio al 1% fin de estabilizar el pH y la turbiedad del agua. Una vez diseñado el mezclador rápido en vertedero rectangular con un ancho de 0,40 m, una altura de 1 m, un largo de 2,08 m. Con la implementación del vertedero rectangular los porcentajes de eficiencia de remoción de los parámetros fuera de norma al realizar las pruebas de jarras al agua tratada son: color= 93,10%, turbiedad= 98,08%, nitritos= 100% y fosfatos= 94,41%. Se recomienda a la Cooperativa de Servicios de Agua Potable y Alcantarillado de la Ciudad de Echeandía la aplicación del estudio realizado para mejorar la eficiencia de la planta actual, a fin de brindar agua potable apta para el consumo de los habitantes.es_ES
dc.description.abstractThis research work is entitled Optimization of the Potable Water Treatment System in the Factory of San Vicente Alto, in the city of Echeandía, in the province Bolivar. Problems generated by water quality were diagnosed by the means of the inductive and deductive method. Physical-chemical and microbiological characterization of water input and output from the treatment Factory in different weather conditions were performed in the technical analysis lab in the Faculty of Sciences of ESPOCH. After water characterization, parameters over permissible limits according to Norm INEN 1108: 2011 “Potable Water. Requissites” were determined such as: color, turbid, nitrites and phosphate specifically in rainy season. To remover these parameter, treatment test with aluminum sulfate and aluminum polichloride were carried out, so the appropriate dose was found, 21,34 kg per day with aluminum polichloride at 1% to stabilize the pH and water turbid. A fast mixer was designed in rectangular overflow with a width of 0,40 m, and height of 1 m, a lengthy of 2,08 m. The implementation of the rectangular overflow generated the removing efficiency percentages over norm at preforming the test of treated water pitcher such as: color= 93, 10%; turbid=98,08%; nitrites=100%, and phosphates=94,41% . It is recommended to the rectangular and Pipe Water Service Company of Echeandía to apply this study in order to improve efficiency of the current Factory and give potable water to human consumees_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazo.es_ES
dc.relation.ispartofseriesUDCTFC;96T00328-
dc.subjectSISTEMA DE POTABILIZACIÓNes_ES
dc.subjectPARÁMETROS DE CALIDADes_ES
dc.subjectDOSIFICACIÓN DE COAGULANTEes_ES
dc.subjectAGUA POTABLEes_ES
dc.subjectPARÁMETROS FÍSICOS – QUÍMICOSes_ES
dc.subjectPARÁMETROS MICROBIOLÓGICOSes_ES
dc.subjectINGENIERÍA QUÍMICAes_ES
dc.subjectECHEANDÍA (CANTÓN)es_ES
dc.subjectBOLÍVAR (PROVINCIA)es_ES
dc.titleOptimización del Sistema de Tratamiento de Agua Potable de la ciudad de Echeandía – provincia Bolívar.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalTapia, Valeria-