Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4804
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBenalcázar, Freddy-
dc.contributor.authorFares Simbaña, Jessica Marlene-
dc.date.accessioned2016-05-26T21:48:16Z-
dc.date.available2016-05-26T21:48:16Z-
dc.date.issued2015-09-
dc.identifier.citationFares Simbaña, Jessica Marlene. (2015). Elaboración de un Protocolo de Control de Calidad mediante el uso del FANTOMA de Acreditación Mamográfico modelo 156 para el equipo de mamografía modelo MAMMOMAT 3000 NOVA del Hospital de Especialidades Fuerzas Armadas No.1. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4804-
dc.descriptionSe elaboró un protocolo de control de calidad mediante el uso del fantoma de acreditación mamográfico modelo 156 para el equipo de mamografía modelo MAMMOMAT 3000 NOVA del Hospital de Especialidades Fuerzas Armadas No.1 con la finalidad de garantizar una alta calidad mamográfica y una baja dosis para la paciente. Esta investigación incluyó un proceso aplicativo descriptivo que incorporó la especificación del estado de funcionamiento del equipo, determinación de los elementos que conforman el área de mamografía, reunificación de pruebas realizadas en protocolos ya establecidos y aplicabilidad de pruebas de control de calidad. Además se dispuso de observación sistemática para examinar los componentes y funcionamiento del equipo mamográfico. El protocolo comprendió una presentación, un segmento descriptivo de referencia a las funciones que realizó el personal involucrado, además del desarrollo de las pruebas de control de calidad. Como resultado se obtuvo que de los parámetros evaluados: pruebas de seguridad del equipo, almacenamiento de películas, sistema de imagen, pruebas del generador y tubo de rayos X, control automático de exposición (CAE), pruebas geométricas, sistema de compresión, calidad de imagen, condiciones de visualización de las imágenes, el 100% de las pruebas se encontraron dentro de los criterios de calidad establecidos en el protocolo. Se concluye que el mamógrafo modelo MAMMOMAT 3000 NOVA funciona correctamente, asegurando un diagnóstico más acertado en la prevención y detección temprana de cáncer de mama, lo que establece una mejora en la calidad del servicio que ofrece el área de mamografía del Hospital de Especialidades Fuerzas Armadas No.1. Para una mejor eficacia del equipo mamográfico se recomienda implementar el presente protocolo de control de calidad en el área de mamografía del Hospital de Especialidades Fuerzas Armadas No.1es_ES
dc.description.abstractA protocol of quality control was elaborated through the use of mammography accreditation phantom model 156 for the mammography equipment model MAMMOMAT 3000 NOVA that belongs to the Hospital de Especialidades Fuerzas Armadas No.1 (The Army Specialties Hospital No.1) as to guarantee a high mammography quality and a low dose for the patient. This research included an applicative descriptive process that incorporated the specification of the functioning status of the equipment, the determination of the elements that constitutes the mammography area, the reunification of conducted tests within established protocols, and the applicability of quality control tests. Moreover, it included systematic observation to examine the components and functioning of the mammography equipment. The protocol had a presentation, a descriptive segment concerning the functions that the staff performed, and the development of the quality control tests. The results showed that the assessed parameters: equipment security tests, film storage, image system, generator and x-ray tube tests, exposition automatic control, geometric tests, compression system, image quality, and image visualization conditions comply with the 100% of the required quality criteria within the protocol. If is concluded that the mammography equipment model MAMMOMAT 3000 NOVA functions correctly. If ensures a reliable diagnosis for early detection and prevention of breast cancer which promotes a better quality service in the area of mammography of the Hospital de Especialidades Fuerzas Armadas No.1. In order to have an even higher performance of the equipment, it is recommended to implement the present protocol of quality control in the area of mammography of the Hospital de Especialidades Fuerzas Armadas No.1.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazo.es_ES
dc.relation.ispartofseriesUDCTFC;86T00023-
dc.subjectPROTOCOLO DE CONTROLes_ES
dc.subjectFANTOMA (INSTRUMENTO)es_ES
dc.subjectMAMOGRAFÍA (TÉCNICA RADIODIAGNÓSTICA)es_ES
dc.subjectMAMMOMAT (MODELO MAMÓGRAFO)es_ES
dc.subjectMAMÓGRAFO (EQUIPO DIGITALIZADO)es_ES
dc.subjectBIOLOGÍAes_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectFÍSICAes_ES
dc.titleElaboración de un Protocolo de Control de Calidad mediante el uso del FANTOMA de Acreditación Mamográfico modelo 156 para el equipo de mamografía modelo MAMMOMAT 3000 NOVA del Hospital de Especialidades Fuerzas Armadas No.1.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalBorja, Myrian-
Aparece en las colecciones: Biofísica