dc.identifier.citationNájera Lucio, Cristian Geovany; Pilataxi Chuqui, José David. (2017). Análisis operacional de los sistemas mecánicos y eléctricos, mediante diagnóstico técnico para establecer el estado del funcionamiento del ascensor del edifico de laboratorios de la Facultad de Mecánica. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6478-
dc.descriptionEl análisis operacional de los sistemas mecánicos y eléctricos mediante diagnostico técnico para establecer el estado del funcionamiento del ascensor de los laboratorios de la Facultad de Mecánica. Verificamos el contexto operacional del ascensor y los componentes que lo conforman, para utilizar técnicas basadas en la condición, para analizar y diagnosticar que cada elemento cumpla con los requerimientos establecidos de funcionamiento. A cada sistema se le asignó la técnica adecuada termografía, con la utilización del equipo SATIR E8, para elementos eléctricos los cuales trabajan a distintas temperaturas en el tablero de control. Análisis vibracional utilizando el equipo VIBRACHECK 200 ABG para componentes mecánicos, donde muestra la variación en frecuencia y amplitud cuando el ascensor trabaja a baja, media y máxima carga, si los parámetros varían pueden afectar cada elemento presente en los componentes mecánicos del ascensor. Por último la técnica de análisis de calidad de energía utilizando el equipo FLUKE 435 SERIES II, contribuye al diagnóstico del buen equilibrio y distribución de tensión a los sistemas eléctricos y mecánicos, ya que la variación de estos sistemas podría llevar a la perdida de uno de estos elementos que conformar el ascensor y pueden generar la inseguridad en los usuarios. Luego del análisis y diagnóstico de las mediciones se obtuvo resultados que presentan variaciones minias que no afectan al sistema de trasmisión, por lo tanto el ascensor actualmente se encuentra en un estado de buen funcionamiento, sin descartar que en un futuro puedan presentar fallas que serán evitada con este tipo de análisis, se recomienda utilizar de manera adecuada cada técnica para llegar a tener datos correctos y se pueda realizar un diagnóstico adecuado.es_ES
dc.description.abstractThe operacional analysis of the mechanical and electric systems, through technical diagnosis to establish, the state of operation of the elevator of the laboratorios in the Faculty of Mechanics. We verify the operational context of the elevator an the components that make it up, to use techniques based on the condition, to analyze and diagnose that each elemet meets the requirements for which they were acquired without exceeding the established operating parameters. Each system was assigned the appropriate thermography technique, using the SATIR E8 equipment, for electrical elements which work at different temperaturas in the control board. Vibration analysis using the VIBRACHECK 200 ABG equipment for mechanical components, showing the varation in frequency and amplitude when the elevator works at low, medium and maximum loads, if the parameters vary can affect each elemet present in the mechanical components of the elevator. Finally the technique of energy quality analysis using the FLUKE 435 SERIES II equipment contributes to the diagnosis of good balance and voltage distribution to the electrical and mechanical systems, since the variation of these systems could lead to the loss of one of these elements that make up the elevator and can generate the insecurity in the users. After the analysis and diagnosis of the measurements were obtained results that present minimal variations that do not affect the transmission system, so the elevator is now in good condition, without ruling out that in the future could present failures that would be avoided with this type of analysis, it is recommended to use each technique in an appropriate way to get the correct data and therefore a correct diagnosis will be obtained.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00288-
dc.subjectCALIDAD DE ENERGÍAes_ES
dc.subjectTERMOGRAFÍAes_ES
dc.subjectDIAGNÓSTICO TÉCNICOes_ES
dc.subjectANÁLISIS DE VIBRACIONESes_ES
dc.subjectMOTOR ELÉCTRICOes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA ELECTRÓNICAes_ES
dc.subjectRIOBAMBA (CANTÓN)es_ES
dc.titleAnálisis operacional de los sistemas mecánicos y eléctricos, mediante diagnóstico técnico para establecer el estado del funcionamiento del ascensor del edifico de laboratorios de la Facultad de Mecánica.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalFiallos Velasco, Pablo-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00288.pdf4,8 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.