Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6666
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAstudillo Machuca, César Eduardo-
dc.contributor.authorQuizhpi Ojeda, Oscar José-
dc.contributor.authorTisalema Malqui, Willian Alejandro-
dc.date.accessioned2017-06-22T16:20:39Z-
dc.date.available2017-06-22T16:20:39Z-
dc.date.issued2017-02-24-
dc.identifier.citationOscar José, Quizhpi Ojeda; Willian Alejandro, Tisalema Malqui. (2017). Análisis de los efectos que produce el arco eléctrico en tableros industriales mediante mediciones indirectas de ultrasonido pasivo. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6666-
dc.descriptionEn este trabajo de titulación se detalla el análisis de los efectos que produce el arco eléctrico en tableros industriales mediante mediciones indirectas de ultrasonido pasivo. Se diseñó una estructura que soporte los elementos que contiene el módulo de pruebas, conformado por elementos eléctricos y dieléctricos destinados a generar un modo de fallo determinado que es regulable de forma manual, con la finalidad de determinar el corte de potencia, pérdida y elevado consumo de energía que se puedan producir. El ultra sonido pasivo es una técnica de análisis basado en la condición que permite visualizar y escuchar, espectros y decibeles de frecuencia según el paso de la corriente en el dispositivo de fallo, para que sea evidente la generación del arco eléctrico se hizo necesario la utilización de consumidores que generen una carga aproximada de 10 amperios. Para tomar las medidas de decibeles generados por el arco se apunta el Ultraprobe 15000 en dirección del dispositivo de fallo y automáticamente se observa en la pantalla del equipo un espectro correspondiente, adicional para complementar el estudio se tomaron en tres puntos de medición valores de voltaje e intensidad, con la finalidad de determinar la potencia y la energía consumida. Por medio de una comparación entre el dispositivo sometido a una carga de 3,3 amperios (carga normal) y una carga de 8,15 amperios (sobre carga), relación entre la generación del arco eléctrico y el elevado consumo de energía. Con esta técnica de análisis de la condición se podrán analizar señales de decibeles que se produce el arco eléctrico en tableros industriales, evitando que estos lleguen al fallo. Previo a la utilización del Ultraprobe 15000 se recomienda familiarizarse con el modo de uso a fin de evitar un posible malfuncionamiento del mismo.es_ES
dc.description.abstractThis thesis is intended to carry out the Analysis of the Effects Produced by the Electric Arc on industrial boards by means of direct measurements of passive ultrasound. In this aim, a support structure for the elements contained in the testing module was made, which consist of electric and dielectric elements intended to generate a determined failure mode from a manual regulation device with the aim to determine the probable potency outage as well as the loss and high electrical power consumption. The passive ultrasound is an analysis technique based on the condition that allows visualizing and listening the spectrum and frequency decibel as the electrical power supply is being done to the failure device. To show how the electrical arc generation occurs, energy consumption devices were used, which generate a 10-ampere load. The procedure followed for measuring the decibels generate by the electrical arc consisted of targeting the 15000- ultraprobe in the direction to the fail device so that it allows automatically observes the corresponding spectrum in the scream and, additionally three points of measures as well as the voltage and intensity values were taken in order to determine the potency and electrical power consumption and thus to compliment the study by making a comparison between the device undergone a 3,3 amperes load ( normal load) and 8,15 amperes load ( over load) and also, the relation between the electrical arc generation and the high electric power consumption. This analysis composition technique enables the decibel signal analysis, which are produced by the electrical arc in the industrial boards preventing the from fails. Therefore, to prevent a possible malfunction of the 15000-ultaraprobe, it is advisable to be familiarized with usage in advance.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00302-
dc.subjectTERMOGRAFÍAes_ES
dc.subjectULTRASONIDO PASIVOes_ES
dc.subjectMODOS DE FALLOes_ES
dc.subjectANÁLISIS DE LA CONDICIÓNes_ES
dc.subjectMANTENIMIENTO PREDICTIVOes_ES
dc.subjectARCO ELÉCTRICOes_ES
dc.subjectEQUIPOS Y HERRAMIENTASes_ES
dc.subjectRIOBAMBA (CANTÓN)es_ES
dc.titleAnálisis de los efectos que produce el arco eléctrico en tableros industriales mediante mediciones indirectas de ultrasonido pasivo.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalHaro Medina, Marco Antonio-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00302.pdf2,83 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.