Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/7903
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCalderón, Hugo-
dc.contributor.authorJaya Guilcapi, Sindia Irene-
dc.date.accessioned2018-01-18T21:05:35Z-
dc.date.available2018-01-18T21:05:35Z-
dc.date.issued2017-11-
dc.identifier.citationJaya Guilcapi, Sindia Irene. (2017). Diseño de un sistema de tratamiento de aguas residuales para la parroquia San Simón, cantón Guaranda, provincia Bolívar. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/7903-
dc.descriptionSe diseñó un sistema de tratamiento de aguas residuales para la parroquia San Simón del cantón Guaranda, provincia de Bolívar, para cumplir con la normativa vigente ambiental y así obtener agua tratada de calidad, minimizando las concentraciones de los parámetros dentro de los límites permisibles establecidos en la Norma del TULSMA, Acuerdo ministerial 097A del 30 de Julio 2015. Tabla 9, Límites de descarga a un cuerpo de agua dulce, es por ello que se optó por realizar 2 muestras compuestas comprendidas de muestras simples por dos meses; mediante la caracterización físico, químico y microbiológica se pudo identificar los siguientes parámetros que se encuentran fuera de los límites permisibles: Color, Turbiedad, Solidos Suspendidos Totales, Nitrógeno total, Bario, Demanda bioquímica de oxígeno, Demanda química de oxígeno y Coliformes Fecales. Se realizó pruebas de tratabilidad por el método de test de jarra con Policloruro de aluminio (PAC) y auxiliar Chemfloc. Al identificar las variables de diseño, se determinó que el sistema de tratamiento de aguas residuales constara de seis equipos: Canal de entrada, Sistema de rejillas, Sedimentador de alta tasa, Canal Parshall, Tanque mezclador, Filtro lento de arena y grava y un Lecho de secado. El diseño propuesto fue validado con los resultados de la caracterización final del agua residual y los porcentajes promedio de remoción de los parámetros: Color 97.27%, Turbiedad 99.46%, Solidos suspendidos totales 86.91%, Nitrógeno total 79.22%, Bario 79.98%, Demanda Bioquímica de Oxigeno 92.71%, Demanda Química de Oxigeno 98.61% y más del 99% de Coliformes fecales. Se recomienda ejecutar el sistema de tratamiento de aguas residuales para evitar la contaminación del Río Guaranda y mejorar la calidad de vida de los habitantes de dicho sector.es_ES
dc.description.abstractA System of wastewater treatment was designed for San Simón, a political-territorial división belonging to Guaranda canton located in Bolívar province. The purpose of this treatment system was to comply the current environmental regulations and thus to obtain quality treated water by reducing the concentrations of the parameters to the permissible limits established in the norm TULSMA, Ministerial Agreement 097 A of July 30, 2015, Table 9, Limits to a body of fresh water. This criteria; was the basis to develop two composite samples comprised of simple samples for two months. By means of the physical, chemical and microbiological characterization, it was possible to determine these parameters outside the permissible limits: colour, turbidity, total suspended solids, total nitrogen, barium, biochemical oxygen demand, chemical oxygen demand and faecal coliforms. Treatability tests were conducted by the test method of jar with Aluminum Polychloride (PAC) and the Chemfloc auxiliary. When identifying the design variables, it was determined that the wastewater treatment system was comprised by six equipment: inlet channel, grid system, high rate settler, Parshall flume, mixer tank, slow sand and gravel filter, and a bed of drying. The proposed design was validated with the outcomes coming from the final characterization of the residual water and the average percentages of removal of the parameters: colour 97.27%, turbidity 99.46%, total suspended solids 86.91%, total nitrogen 79.22 %, Barium 79.98%, biochemical oxygen demand 92.71%, chemical oxygen demand 98.61%, and more than 99% of faecal coliforms. Implementing this system of wastewater treatment is recommended to avoid contamination of the Guaranda River, and improve the life quality of the inhabitants surrounding it.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00416-
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectTEST DE JARRA (MÉTODO)es_ES
dc.subjectFILTRO LENTOes_ES
dc.subjectAGUA RESIDUAL DOMÉSTICAes_ES
dc.subjectGUARANDA (CANTÓN)es_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para la parroquia San Simón, cantón Guaranda, provincia Bolívar.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalLeón, Gerardo-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00416.pdf2,74 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.