Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/7912
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMejía, Teresita-
dc.contributor.authorMacera Veintimilla, Diana Cristina-
dc.date.accessioned2018-01-19T16:59:20Z-
dc.date.available2018-01-19T16:59:20Z-
dc.date.issued2017-11-
dc.identifier.citationMacera Veintimilla, Diana Cristina. (2017). Diseño de un sistema para el tratamiento de los lodos generados en la planta de potabilización de la EPMAPA-Sucúa, ubicada en el sector “El Topo”. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/7912-
dc.descriptionEl objetivo fue diseñar un sistema para el tratamiento de los lodos generados en la Planta de Potabilización de la Empresa Pública Municipal de Agua Potable y Alcantarillado de Sucúa, (EPMAPA-S) ubicada en el sector El Topo, provincia de Morona Santiago. La investigación se inició con la caracterización de muestras de los lodos descargados durante la purga y lavado de sedimentadores y retrolavado de filtros, donde de acuerdo con los resultados se consideró tratarúnicamente a los lodos de los sedimentadores debido a que la presencia tanto de Sólidos totales y de Sulfato de aluminio que se encuentran fuera de la normativa. Para el dimensionamiento del sistema de tratamiento de lodos se realizó pruebas preliminares de sedimentabilidad donde se estableció el tiempo promedio de sedimentación, además de la determinación del caudal de purga que fue de 2,4 m3 /d, y la caracterización físico-química de los lodos generados, determinándose que las concentraciones de Sólidos totales, Sedimentables, Suspendidos, Turbiedad y pH fueron de 22500 mg/L, 790 mL/L, 21560 mg/L, 6,69 y 11300 NTU respectivamente. A partir de dichos valores se procedió a realizar el dimensionamiento del sistema propuesto, el mismo que constará de un tanque homogenizador de 36 m3 de volumen; un espesador de lodos por gravedad de 9 m3 y dos lechos de secado de 12,69 m de longitud, 3,5 m de ancho y 2,09 m de profundidad, los mismos que permitirán la deshidratación de los lodos en un período de 13 días. El diseño propuesto ayudará reducir el volumen de fango generado en el proceso de tratamiento en un 40 % con lo que podrá disponerse en el relleno sanitario. Se recomienda realizar análisis físicoquímicos al agua del clarificado sobrenadante obtenido del espesador de lodos por gravedad y eras de secado para verificar sus características de descarga.es_ES
dc.description.abstractThe objective was to design a system for the treatment of sludge generated in the Potabilization Plant of the Municipal Public Company of Drinking Water and Sewerage – Sucúa (EPMAPA-S) located in the El Topo sector, Morona Santiago province. The investigation began with the characterization of the sludge discharged during the purging and washing of settling tanks and backwashing of filters, where according to the results it was considered to treat only the sludge from the settlers because the presence of both total Solids and Aluminun Sulphate that are outside the regulations. For the sizing of the sludge treatment system, preliminary sedimentation test were performed where the average sedimentation time was established, in addition to the determination of the purge flow rate of 2,4 m3 /d, and the physical-chemical characterization of the generated sludge, determining are the concentration of Total Solids, Sedimentables, Suspended, Turbidity and pH were 22500mg/L, 790mL/L, 21560mg/L, 6,69 and 11300 NTU respectively. From these values, the sizing of the proposed system was carried out, which will consist of a homogenizer tank of 36 m3 of volumen; a slugde thickener, by gravity of 9m3 and two drying beds of 12,69m in length, 3,5m in width and 2,09m in Depth, which will allow the dehydration of the slugde in a period of 13 days. The proposed design will help to reduce de volumen of sludge generated in the treatment process by 40% that can be disposed in the sanitary landfill. It is recommended to carry out physical-chemical analyzes to the wáter of the clarified supernatant obtained from the sludge thickener by gravity and drying times to verify its discharge characteristics.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0311-
dc.subjectBIOTECNOLOGÍAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectAGUA POTABLEes_ES
dc.subjectLODOS QUÍMICOSes_ES
dc.subjectHOMOGENIZADOR DE LODOSes_ES
dc.subjectESPESADOR DE LODOSes_ES
dc.subjectLECHOS DE SECADOes_ES
dc.titleDiseño de un sistema para el tratamiento de los lodos generados en la planta de potabilización de la EPMAPA-Sucúa, ubicada en el sector “El Topo”.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalLeón, Gerardo-
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0311.pdf4,73 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.