Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8040
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorHernández Dávila, Eduardo Segundo-
dc.contributor.authorJaya Vacacela, Milton David-
dc.contributor.authorPaguay Cali, Diego Santiago-
dc.date.accessioned2018-02-19T19:57:43Z-
dc.date.available2018-02-19T19:57:43Z-
dc.date.issued2017-11-21-
dc.identifier.citationJaya Vacacela, Milton David; Paguay Cali, Diego Santiago. (2017). Construcción de un módulo de pruebas para simular modos de falla en sistemas de transmisión de potencia con polea para el laboratorio de diagnóstico técnico. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8040-
dc.descriptionEl estudio realizado como trabajo de titulación, que tiene con objetivo la construcción de un módulo de pruebas para simular modos de falla en sistemas de transmisión de potencia con polea, aporta útilmente para la formación de los estudiantes de la Escuela de Ingeniería de Mantenimiento, debido a que el módulo construido permite realizar diferentes desalineaciones de poleas tales como: desalineación paralela, desalineación angular horizontal y desalineación angular vertical. En primera instancia para la construcción del módulo, se estableció una selección correcta de los elementos como: motor jaula de ardilla con una potencia de 1Hp, el alternador de 12 V y 32 A, que proporcionara la carga al sistema, la correa trapezoidal que trasmite el movimiento, y dos poleas con una relación de transmisión 1 a 1. Para provocar las distintas desalineaciones se elaboró la metodología para cada desalineación, además de un procedimiento detallado de la utilización de los equipos necesarios para el estudio. Posteriormente se realizó un análisis vibracional con el equipo Vibracheck 200 ABG, y el estudio de la calidad de energía con el equipo Fluke 435 II. Antes de provocar las distintas desalineaciones, el módulo debe estar en condiciones óptimas de funcionamiento, para tener un espectro característico que sirva como punto de partida para iniciar el desalineamiento. Con los valores obtenidos mediante las desalineaciones, se realizó graficas de tendencia, evidenciando mayor consumo energético e incremento del nivel de Vibración Global (RMS), a medida que el grado de desalineación aumenta, demostrando que el módulo cumple la función para la cual fue construido.es_ES
dc.description.abstractThe study aims to build a test module to simulate failure modes in pulley power transmission systems. This test module provides a useful training for students of Maintenance Engineering School due to module allows to carry out different pulley misalignments such as: parallel misalignment, horizontal/angular misalignment and vertical/angular misalignment. First, to build the module, an adequate items selection was established such as: a squirrel-cage motor with 1 Hp power, a 32 A - 12 volt alternator which will provide the system load, the movement is transmitted by the V-belt as well as two pulleys with a transmission ratio of 1:1. The methodology to make the different misalignment was developed, as well as a detailed procedure for the use of the equipment required for this study. Afterwards, a Vibration Analysis by using Vibracheck 200 ABG equipment and the energy quality study by using Fluke 435 II equipment were carried out. The module must ensure optimal operational conditions before to generate the different misalignments in order to have a characteristic spectrum as a starting point to start the misalignment. Trend Graph was made with the obtained values by means of the misalignments to show higher energy consumption as well as an overall vibration level (RMS) as the misalignment increases. It shows that the module performs the function for which it was designed.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00317-
dc.subjectSISTEMA DE TRASMISIÓNes_ES
dc.subjectCORREA TRAPEZOIDALes_ES
dc.subjectANÁLISIS DE VIBRACIONESes_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectESPECTRO CARACTERÍSTICOes_ES
dc.subjectMODOS DE FALLAes_ES
dc.titleConstrucción de un módulo de pruebas para simular modos de falla en sistemas de transmisión de potencia con polea para el laboratorio de diagnóstico técnico.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCalderón Freire, Edisson Fernando-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00317.pdf3,99 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.