Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8076
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCaicedo Reyes, Jorge Isaías-
dc.contributor.authorGuananga Moreno, Andrés Marcelo-
dc.date.accessioned2018-02-27T14:07:16Z-
dc.date.available2018-02-27T14:07:16Z-
dc.date.issued2017-10-13-
dc.identifier.citationGuananga Moreno, Andrés Marcelo. (2017). Estudio para selección, diseño de instalaciones, plan de mantenimiento y seguridad de los calderos para la piscina semi-olímpica del balneario turístico Los Elenes del Cantón Guano" . Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8076-
dc.descriptionEl principal objetivo es elaborar un estudio para selección, diseño de instalaciones, plan de mantenimiento y seguridad de las nuevas calderas para la piscina semi-olímpica del balneario turístico Los Elenes del Cantón Guano, el cual incluirá cálculos de selección de equipos, diseño de distribución de instalaciones de la sala de caldera. La metodología a seguir es; primero proceder a la recolección de todos datos en la piscina y su ambiente como son; temperaturas, humedades relativas, volúmenes de agua, caudales. Mediante el cálculo de la cargar térmica enfocados en la normativa ASME PTC 4.0 2008 y otras consideraciones generales para seleccionar los equipos adecuados para el sistema de generación de vapor; también en base a las normativas ANSI A13.1, ISO 9001, OHSAS 18001, ISO 14001, así como las leyes vigentes en nuestro país se procederá a diseñar la distribución de sus instalaciones, realizar un plan de mantenimiento, elaborar un plan de seguridad para salvaguardar la integridad del personal, ambiente y equipos del sistema. Se realizará un análisis de costos en función de beneficios y gastos del balneario para la factibilidad de ejecución y puesta en marcha de este estudio por parte del GAD del cantón Guano. Finalmente, luego de haber realizado la interpretación bajo normalización y criterio técnico de todos los resultados obtenidos se concluirá con la selección de los equipos necesarios para el sistema de generación de vapor que constará de una caldera pirotubular horizontal, un sistema de ablandamiento de agua, un sistema de alimentación de agua, un sistema de alimentación de combustible, un sistema de inyección de químicos y un intercambiador de calor. Además, se recomendará prestar la atención debida a todos los criterios mencionados en el presente trabajo para instalar un sistema eficiente, seguro y que preste facilidades a la hora de realizar mantenimientos.es_ES
dc.description.abstractThe main objetive is to carry out a study for the selection, design of facilities, maintenance plan and safety of the new boilers for the semi-olympic swimming spa Los Elenes, in Guano Cantón. It includes calculations of equipement selection, desing of distribution facilities of the boiler room. The methodology to follow is; first proceed to collect all the data in the pool and its environment such as; temperature, relative humidities, volume of water, flows. Through ASME PTC 4.0 2008 and other general considerations to select the appropriate equipment for the steam generation system; also based on the ANSI A13.1, ISO 9001, OHSAS 18001, ISO 14001 regulations, as well as the existing laws in our country. It will proceed to desing the distribution of the facilities, a maintenance plan was prepared, a security plan safeguard the integrity of the personnel, environment and equipment of the system. A cost analysis has been carried out according to the benefits and expenses of the spa for the feasibility of execution and implementation of this study by GAD of Guano Cantón. Finally, after the interpretation under standardization and technical criteria of all the results were performed. It will conclude with the selection of the necessary equipment for the steam generation system that will consist of a horizontal shell boiler, a water softening system, a water supply system, fuel supply system, chemical injection system and a calorie exchanger. In addition, it is recommended to pay attention to all the criteria established in this work to install an efficient, safe system that provides facilities for maintenance.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;15T00675-
dc.subjectGENERADOR DE VAPOR (Caldera)es_ES
dc.subjectDISTRIBUCIÓN DE INSTALACIONESes_ES
dc.subjectPLAN DE MANTENIMIENTOes_ES
dc.subjectPLAN DE SEGURIDADes_ES
dc.subjectANÁLISIS DE COSTOSes_ES
dc.subjectGUANO (CANTÓN)es_ES
dc.titleEstudio para selección, diseño de instalaciones, plan de mantenimiento y seguridad de los calderos para la piscina semi-olímpica del balneario turístico Los Elenes del Cantón Guano"es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalViteri Núñez, Edwin Fernando-
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00675.pdf4,37 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.