Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8078
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMoreno Romero, Telmo-
dc.contributor.authorGuaman Caba, Paul Alejandro-
dc.contributor.authorMuñoz Valle, Christian Mauricio-
dc.date.accessioned2018-02-27T14:43:12Z-
dc.date.available2018-02-27T14:43:12Z-
dc.date.issued2017-11-17-
dc.identifier.citationGuaman Caba, Paul Alejandro; Muñoz Valle. Christian Mauricio. (2017). Análisis de datos de un chiller para determinar el comportamiento de las curvas de enfriamiento del propilenglicol y su comparación con el cloruro de calcio. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8078-
dc.descriptionLa reducción de consumo energético ha motivado a mejorar los sistemas de refrigeración existentes por lo tanto se analizó el funcionamiento de un equipo chiller y el comportamiento del refrigerante secundario a base de propilenglicol en reemplazo de la solución de cloruro de calcio, esto con la finalidad de obtener el funcionamiento eficiente de este equipo. La fase experimental de este proyecto evalúa 218 litros de solución de propilenglicol a una concentración de 15%, 21% y 30%. Las variables de análisis del proyecto son temperatura, caudal y tiempo, las mismas que son adquiridas mediante una interfaz de usuario con la utilización del software LabView, esta interfaz además facilita el control de un servo motor que acciona una válvula para conseguir la variación del caudal de circulación del propilenglicol, lo que ha permitido observar la influencia del caudal sobre el proceso de refrigeración en sistemas indirectos. El enfriamiento de la solución de propilenglicol inicia desde la temperatura ambiente hasta temperaturas cercanas a los -10 °C dependiendo de las propiedades de la solución. Los datos obtenidos permiten la realización de curvas de enfriamiento del refrigerante secundario, las curvas muestran una variación de temperatura y de velocidad de enfriamiento distintas al comportamiento de las curvas de enfriamiento del cloruro de calcio, en el que la solución de propilenglicol requiere de mayor tiempo para llegar a la misma temperatura que la solución de cloruro de calcio, esto conlleva a que desde el punto de vista térmico el propilenglicol tiene propiedades inferiores que la salmuera de cloruro de calcio, aunque a nivel práctico se necesita analizar mayor cantidad de los aspectos según la aplicación para realizar una selección optima de un refrigerante secundario como se muestra en el desarrollo de este documento.es_ES
dc.description.abstractThe reduction of energy consumption has motivated to improve the existing refrigeration systems, therefore the operation of a chiller equipment and the behavior of the secondary refrigerant based on propylene glycol in replacement of the calcium chloride solution was analyzed, this with the purpose of get the efficient operation of this equipment. The experimental phase of this project evaluates 218 liters of propylene glycol solution at a concentration of 15%, 21% and 30%. The variables of analysis of the project are temperature, flow and time, which are acquired through a user interface with the use of LabView software, this interface also facilitates the control of a servo motor that drives a valve to achieve the variation of the flow of propylene glycol circulation, which has made it possible to observe the influence of the flow on the refrigeration process in indirect systems. The cooling of the propylene glycol solution starts from room temperature to temperatures close to -10 ° C depending on the properties of the solution. The data obtained allow the realization of cooling curves of the secondary refrigerant, the curves show a variation of temperature and cooling speed different from the behavior of the cooling curves of calcium chloride, in which the propylene glycol solution requires more time to reach the same temperature as the calcium chloride solution, this leads to the fact that from the thermal point of view propylene glycol has lower properties than calcium chloride brine, although at a practical level it is necessary to analyze a greater number of aspects according to the application in order to make an optimal selection of a secondary refrigerant as shown in the development of this document.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;15T00677-
dc.subjectCHILLER (EQUIPO DE REFRIGERACIÓN)es_ES
dc.subjectPROPILENGLICOL (ANTICONGELANTE)es_ES
dc.subjectCLORURO DE CALCIOes_ES
dc.subjectCURVA DE ENFRIAMIENTOes_ES
dc.subjectREFRIGERANTE SECUNDARIOes_ES
dc.subjectANTICONGELANTEes_ES
dc.titleAnálisis de datos de un chiller para determinar el comportamiento de las curvas de enfriamiento del propilenglicol y su comparación con el cloruro de calcio.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalViteri Núñez, Edwin Fernando-
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00677.pdf2,48 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.