Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8638
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCalderón, Segundo Hugo-
dc.contributor.authorTrujillo Ruales, Henry Bryan-
dc.date.accessioned2018-08-14T19:34:29Z-
dc.date.available2018-08-14T19:34:29Z-
dc.date.issued2018-03-
dc.identifier.citationTrujillo Ruales, Henry Bryan. (2018). Diseño de un sistema de tratamiento de aguas residuales para la parroquia Facundo Vela, del cantón Guaranda provincia de Bolívar. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8638-
dc.descriptionEl presente trabajo de titulación, se realizó con el propósito de minimizar la contaminación de la principal arteria geográfica que pasa por el sector; aparte de cumplir con lo establecido en la normativa ambiental vigente. Para ello se diseñó un Sistema de Tratamiento de Aguas Residuales para la Parroquia Facundo Vela, del Cantón Guaranda, Provincia de Bolívar. En la cual se determinó el caudal generado, tomándose como referencia los meses de junio y julio del presente año, por motivo en que dichos meses se presentaba las estaciones de invierno y verano respectivamente, tomándose mediciones en cada mes por siete días consecutivos, determinándose el caudal promedio de estos meses, siendo de 4.2 L/s. Para la caracterización primaria del agua residual, se tomaron muestras compuestas, se obtuvieron los siguientes parámetros que se encuentran fuera de Norma: aluminio, bario, cinc, cloruros, cobre, sulfato, DBO5, DQO, fluoruros, fósforo total, nitrógeno amoniacal y sólidos suspendidos totales. Se calculó el índice de biodegradabilidad obteniéndose un valor de 0.348, lo que indica que el agua a tratar es biodegradable, por tal motivo se establece un Sistema de Tratamiento combinado cuya propuesta es: rejillas, canal, reactor biológico, coagulación-floculación, sedimentador secundario, filtro de arena-grava y carbón activado. Se realizaron las respectivas pruebas de tratabilidad y de test de jarras a nivel de laboratorio, en las cuales nos permitieron determinar las dosificaciones óptimas de coagulante y floculante, siendo: PAC 4 ppm, auxiliar iónico CHEMFLOC N-932 0,8 ppm, se realizó un balance de remoción de contaminantes en cada etapa del proceso. Finalmente, el agua tratada fue validada en el laboratorio del CESTTA. Con el diseño de la planta de tratamiento propuesto se obtuvo una eficiencia del 97.18 % concluyendo que el tratamiento es fiable para su ejecución.es_ES
dc.description.abstractThe present research work was carried out with the purpose of minimizing the contamination of the main geographic artery that passes through the sector, apart from complying with the provisions of current environmental regulations, for this reason, Residual Water Treatment System was designed for the Facundo Vela Parish, of the Guaranda Canton, Bolívar Province. In which the generated flow was determined, taking as a reference the months of June and July of this year, for the reason that months were the winter and summer seasons respectively, taking measurements in each month for seven consecutive days, determining the average flow of these months, being 4.2 L / s. For the primary characterization of the residual water, composite samples were taken, the following parameters were obtained that are outside Norma: aluminum, barium, zinc, chlorides, copper, sulfate, DB05, DQO, fluorides, total phosphorus, ammonia nitrogen and solids suspended total. The biodegradability index was calculated obtaining a value of 0.348, which indicates that the water to be treated it is biodegradable, for this reason, a Combined Treatment System is established and the proposal is: grids, channel, biological reactor, coagulation-flocculation, secondary sedimentation, sand-gravel filter and active carbon. The respective treatability and jar test were carried out the laboratory level, in which it was determined the optimal coagulant and flocculant dosages, being: PAC 4 ppm, CHEMEFLOC N-9320.8 PPM ionic auxiliary, a balance of removal of contaminants in each stage of the process. Finally, the treated water was valid in the CESTTA laboratory. With the design of the proposed treatment plant, an efficiency of 97.18% was obtained, concluding that the treatment is reliable for its execution.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00440-
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectDISEÑO DE PLANTA DE TRATAMIENTOes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectPRUEBAS DE TRATABILIDADes_ES
dc.subjectCÁLCULOS DE INGENIERÍAes_ES
dc.subjectFACUNDO VELA (PARROQUIA)es_ES
dc.subjectBOLIVAR (PROVINCIA)es_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para la parroquia Facundo Vela, del cantón Guaranda provincia de Bolívar.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZambrano, Mayra-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00440.pdf3,35 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.