dc.identifier.citationLoza Quihuiri, Eduardo Patricio; Martínez Suarez, Darío Javier. (2017). Diagnóstico de fallas en los sistemas eléctrico, mecánico, y reparación del ascensor porta camillas del Hospital Pediátrico Alfonso Villagómez Román, bajo los lineamientos de mantenimiento correctivo planificado. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/9602-
dc.descriptionEl presente trabajo de titulación describe el diagnóstico de fallas en los sistemas eléctrico, mecánico, y reparación del ascensor porta camillas del Hospital Pediátrico Alfonso Villagómez Román, a través de la dirección del mantenimiento correctivo planificado. Las tareas de diagnosticar y reparar el ascensor parten con el conocimiento de la ausencia de un procedimiento técnico de intervención tras la aparición de la falla. Se desarrolla el trabajo efectuando un análisis de la disponibilidad para el ascensor porta camillas del H.P.A.V.R, como parte del procedimiento de diagnóstico, para con ello alcanzar el nivel de disponibilidad requerida, como resultado del buen funcionamiento del ascensor luego de su reparación. Esto se alcanzó mediante una revisión técnica del ascensor y estudio detallado de las fallas, a su vez también planificando las estrategias de reparación por medio de la gestión de fallas, para lo cual fue necesaria la lectura de las dimensiones del ascensor y varios de sus sistemas. Como resultado se diagnosticó las fallas en los sistemas eléctrico, mecánico, a través de la determinación del estado técnico obtenida de una revisión técnica, estado técnico que contempla condiciones de mantenimiento, calidad y seguridad encontrados, resumidos principalmente dentro de los cinco porqués. Se reparó el equipo a través de procedimientos de mantenimiento generados en la gestión de fallas que resultan en órdenes de trabajo específicas lo que permite recuperar la disponibilidad del ascensor. Además, que es recomendable implementar un plan de mantenimiento preventivo para cumplir con ello, el requerimiento de calidad impartido por la norma NEC-10 PARTE 9-3, artículo 23. Se debe capacitar al personal técnico de mantenimiento del hospital con el fin de cumplir con la norma NEC-10 PARTE 9-3, artículo 23.5 y con ello garantizar el desempeño adecuado del ascensor.es_ES
dc.description.abstractThis work is a description of the failure diagnosis in the electrical, mechanical and repairing systems of a stretcher lift of Alfonso Villagómez Román Children’s hospital (HPAVR) using the planned corrective maintenance. By determining the lack of technical procedure of intervention after occurring a failure, the elevator was diagnosed and repaired. As part of the diagnosis, the elevator availability was analyzed to meet the required level of availability as a result of the good elevator performance after being repaired. This was gotten with the technical elevator check, detailed failure study, and repairing strategy planning according to failure management. That’s why, it was necessary the reading of the dimensions of the elevator and several of its system. As a consequence, failures in the electrical and mechanical systems were diagnosed determining the technical condition after the technical check, technical condition including maintenance conditions, quality and safety which are summarized in 5-whys. The equipment was repaired using maintenance procedures generated in the failure management resulting in specific work order (WO). Thus, elevator was available again. It is recommended to implement a preventive maintenance plan to comply with the regulation NEC-10 PARTE 9-3, Art. 23.5 and to train its staff to comply with NEC-10 PARTE 9-3, Art. 23.5 so that the appropriate elevator performance can be guaranteed.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00329-
dc.rightsInfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectMANTENIMIENTO CORRECTIVOes_ES
dc.subjectASCENSORes_ES
dc.subjectDISPONIBILIDADes_ES
dc.subjectINDISPONIBILIDADes_ES
dc.subjectTÉCNICAS Y HERRAMIENTAS DE MANTENIMIENTOes_ES
dc.subjectCAUSA DE FALLOes_ES
dc.titleDiagnóstico de fallas en los sistemas eléctrico, mecánico, y reparación del ascensor porta camillas del Hospital Pediátrico Alfonso Villagómez Román, bajo los lineamientos de mantenimiento correctivo planificado.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalViscaíno Cuzco, Mayra Alexandra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00329.pdf2,41 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons