Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/13424
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorDelgado López, Verónica Carolina-
dc.contributor.authorUrquizo Buitrago, Sarai Ibeth-
dc.date.accessioned2020-01-13T16:25:20Z-
dc.date.available2020-01-13T16:25:20Z-
dc.date.issued2019-12-11-
dc.identifier.citationUrquizo Buitrago, Sarai Ibeth. (2019). Validación de una fórmula de predicción de peso seco en relación a parámetros clínicos y bioimpedancia espectroscópica en pacientes de hemodiálisis 2017. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13424-
dc.descriptionEl objetivo fue validar de una fórmula de predicción de peso seco en relación al peso determinado por parámetros clínicos y bioimpedancia espectroscópica en pacientes de hemodiálisis 2017. Estudio de tipo analítico no experimental de corte transversal; con enfoque investigativo cuantitativo correlacional. Participaron 96 pacientes en terapia de reemplazo renal en hemodiálisis. Se tomaron datos antropométricos y se realizó un análisis de bioimpedancia espectroscópica para determinar el peso seco. La información se registró en una base de datos en Excel y se procesó con el software JMP 5.1. Para la validación de la fórmula de peso seco dada por parámetros antropométricos se consideró como Gold estándar al peso seco dado por bioimpedancia. Se realizó la prueba estadística pareada intrasujeto. Se generó una fórmula de predicción de peso seco con el método regresión lineal múltiple. El rango de edad de los sujetos que participaron en el estudio fue de 24 a 82 años con una distribución por sexo mayor para los varones (51%) frente a mujeres (49%). El peso seco determinado por parámetros antropométricos en comparación con el peso seco por bioimpedancia mostró ser diferente (p=<0.05) sin embargo se encontró una correlación lineal proporcional entre ambos pesos (r2= 0,68). No se encontró diferencias significativas entre el peso determinado por parámetros clínicos y el de bioimpedancia. (p= 0.003). En conclusión, la fórmula de predicción de Ramírez, al determinar un peso seco diferente al peso determinado por bioimpedancia, no podría usarse como método para la determinación de peso seco en pacientes con Terapia de Reemplazo renal en hemodiálisis, por lo tanto, se rechaza la hipótesis. Se recomienda su uso de la formula antropométrica desarrollada en este estudio como método de evaluación y seguimiento, para pacientes con insuficiencia renal terminal.es_ES
dc.description.abstractThe objective was to validate a dry weight prediction formula in relation to the weight determined by clinical parameters and spectroscopic bioimpedance in 2017 hemodialysis patients. Study of a non-experimental analytical type of cross-section; with a quantitative correlational research approach. 96 patients participated in renal replacement therapy on hemodialysis. Anthropometric data was scammed and a spectroscopic bioimpedance analysis was performed to determine dry weight. The information is recorded in a database in Excel and processed with JMP 5.1 software. For the validation of the dry weight formula given by anthropometric parameters the dry weight given by bioimpedance was considered as standard Gold. The intrasubject paired statistical test was performed. A dry weight prediction formula was generated with the multiple linear regression method. The age range of the subjects who participated in the study was 24 to 82 years with a greater distribution by sex for men (51%) versus women (49%). The dry weight determined by anthropometric parameters compared to the dry weight by bioimpedance showed to be different (p- <0.05), however, a proportional linear correlation was found between both weights (r2 = 0.68). No significant differences were found between the weight determined by clinical parameters and that of bioimpedance- (p = 0.003). In conclusion, the Ramírez prediction formula, when determining a dry weight different from the weight determined by bioimpedance, could not be used as a method for the determination of dry weight in patients with renal replacement therapy in hemodialysis, therefore; The hypothesis is rejected. Its use of the anthropometric formula developed in this study as an evaluation and follow-up method was recommended for patients with end-stage renal failure.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTIPEC;20t01294-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS MÉDICASes_ES
dc.subjectNUTRICIÓNes_ES
dc.subjectVALIDACIÓNes_ES
dc.subjectFORMULA DE PREDICCIÓNes_ES
dc.subjectPESO SECOes_ES
dc.subjectPARÁMETROS CLÍNICOSes_ES
dc.subjectBIOIMPEDANCIA ESPECTROSCOPIAes_ES
dc.subjectHEMODIÁLISISes_ES
dc.titleValidación de una fórmula de predicción de peso seco en relación a parámetros clínicos y bioimpedancia espectroscópica en pacientes de hemodiálisis 2017.es_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.contributor.miembrotribunalVillavicencio Barriga, Verónica Dayana-
dc.contributor.miembrotribunalGavidia Castillo, Mayra Alejandra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Maestrias: Modalidad Proyectos de Investigación y Desarrollo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
20T01294.pdf3,47 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons