Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21066
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPilco Bonilla, Gisela Alexandra-
dc.contributor.authorLanda Landa, Oleas Morales, Tatiana Nicole Yajaira Estefanía-
dc.date.accessioned2024-05-14T15:12:46Z-
dc.date.available2024-05-14T15:12:46Z-
dc.date.issued2023-05-12-
dc.identifier.citationLanda Landa, Yajaira Estefanía; Oleas Morales, Tatiana Nicole. (2023). Desarrollo y validación de un método analítico HPLC para la valoración del salicilato de metilo en forma farmacéutica spray en el Laboratorio Neofarmaco del Ecuador CIA. LTDA. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21066-
dc.descriptionEl trabajo que se presenta a continuación describe el desarrollo y la validación de un método de cromatografía de alta eficiencia (HPLC) de fase reversa, para la cuantificación de salicilato de metilo en estándar y placebos cargados en forma farmacéutica spray. Se utilizó una columna LiChrospher® 100 RP-8 (125 x 4 mm, 5um). La fase móvil consistió en metanol y un buffer de ácido orto fosfórico 1% utilizando el gradiente 60:40, con un flujo de 1 ml/min a 25°C. El volumen de inyección de la muestra fue de 10 ul. Posterior al desarrollo del método se procedió a validarlo, de acuerdo a la categoría 1 de Procedimientos analíticos para la cuantificación de los componentes principales de fármacos a granel o ingredientes activos en productos farmacéuticos terminados, descrita en la USP para la validación, demostrando ser un ser selectivo con un porcentaje de discrepancia de áreas 1,449 % y de tiempo 0,186%; lineal para el estándar r=0,999979 (linealidad del sistema), placebo cargado (linealidad del método 1) r= 0,999493 y para el placebo cargado más yodopovidona (linealidad del método 2) r=0,999365, preciso con una repetibilidad del sistema de (RSD=0,2123), método (RSD=0,6328) y con una precisión intermedia de (RSD= 0,567), exacto (recuperación del 97,12%) , estable con un RSD que no supera el 20% de degradación. Una vez analizados todos estos resultados, se demostró que el método analítico desarrollado y validado es apropiado para la identificación y cuantificación de salicilato de metilo en forma farmaceútica spray y puede ser aplicado para el control de rutina en el laboratorio.es_ES
dc.description.abstractThe following research describes the development and validation of a reversed-phase highperformance chromatography (HPLC), method for the quantification of methyl salicylate in standard and pharmaceutically spray-loaded placebos. A LiChrospher® 100 RP-8 column (125 x 4 mm, 5um) was used. The mobile phase consisted of methanol and 1% ortho-phosphoric acid buffer using 60:40 gradient with a flow rate of 1 ml/min at 25°C. The sample injection volume was 10 ul. After method development, the method was validated according to Category 1 of the Analytical Procedures for the Quantification of Principal Components of Bulk Drugs or Active Ingredients in Finished Pharmaceutical Products, described in the USP for the validation of the method. It showed to be selective with a percentage discrepancy of areas 1.449 % and time 0.186%, linear for standard r=0.999979 (system linearity), placebo loaded (method 1 linearity) r= 0.999493 and for placebo loaded plus iodopovidone (method 2 linearity) r=0.999365, precise with a system repeatability of (RSD=0.2123), method (RSD=0.6328) and with an intermediate precision of (RSD= 0.567), accurate (recovery of 97.12%), and stable with a RSD not exceeding 20% degradation. After analyzing all these results. It was demonstrated that the analytical method developed and validated is suitable for the identification and quantification of methyl salicylate in spray pharmacological form. Besides, it can be applied for routine control in the laboratory.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;56T01287-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOQUÍMICAes_ES
dc.subjectMÉTODO ANALÍTICOes_ES
dc.subjectCROMATOGRAFÍA LÍQUIDA DE ALTA EFICIENCIA (HPLC)es_ES
dc.subjectVALIDACIÓNes_ES
dc.subjectSALICILATO DE METILOes_ES
dc.titleDesarrollo y validación de un método analítico HPLC para la valoración del salicilato de metilo en forma farmacéutica spray en el Laboratorio Neofarmaco del Ecuador CIA. LTDAes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalVinueza Tapia, Diego Renato-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Bioquímico/a y Farmacéutico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
56T01287.pdf929,47 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons