dc.contributor.advisorQuinga Morales, Milton Israel-
dc.contributor.authorVilema Orozco, Ronny Alexis-
dc.contributor.authorVilla Chafla, Hugo David-
dc.date.accessioned2024-06-12T22:11:19Z-
dc.date.available2024-06-12T22:11:19Z-
dc.date.issued2024-01-17-
dc.identifier.citationVilema Orozco, Ronny Alexis; Villa Chafla, Hugo David. (2024). Análisis de la concentración de gases contaminantes en las fosas de revisión técnica vehicular de la Empresa Publica Mancomunada de Tránsito de Tungurahua (EPMTT) para el diseño e implementación de un sistema de ventilación. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21560-
dc.descriptionEn el presente trabajo de titulación se implementó un sistema de ventilación (extracción) de gases como el monóxido de carbono (CO), dióxido de carbono (CO2) y aire, en las diferentes fosas del centro de revisión técnica vehicular de la provincia de Tungurahua en el cantón Pelileo, donde se pudo verificar la concentración de los gases mencionados con el equipo MSA Orión plus que registra la contaminación del aire interior de las fosas de CO en ppm y CO2 en porcentaje de concentración, la medición se realizó durante la jornada normal de trabajo del centro, para la determinación de los parámetros de selección del ventilador como presión estática y caudal de extracción, se siguieron los 6 pasos descritos en el manual de ventilación de Soler y Palau del año 2012. En los resultados se determinó, que el extractor ideal para remover el caudal presente en las fosas de revisión es el extractor centrifugo modelo Bs 700 que tiene la capacidad de mover caudales de 675 𝑚3 ℎ , así como una emisión sonora máxima de 66 dB, dicha emisión es considerada para la exposición diaria de 8 horas de trabajo con las que cumplen los técnicos durante su jornada laboral. Con los caudales de extracción calculados y los niveles de concentración de CO y CO2 se logró determinar el aumento de presión en las tuberías y las perdidas por accesorios, para los diferentes gases a ser evacuados se usó el software SOLID WORKS. El sistema de control automático de los extractores fue diseñado con sensores fotoeléctricos y de un autómata para el funcionamiento independiente de los 4 extractores, de esta manera se garantiza que los gases vayan a los exteriores de las fosas cumpliendo con una descarga libre y asegurando que estos gases no vuelvan a circular hacia adentro, garantizando el sistema de ventilación diseñado.es_ES
dc.description.abstractIn this work, a system of ventilation (extraction) of gases such as carbon monoxide (CO), carbon dioxide (CO2) and air was implemented in the different pits of the vehicle technical inspection center in Tungurahua province, Pelileo canton, where it was possible to verify the concentration of the mentioned gases with the MSA Orion plus equipment that records the contamination of the air inside the pits of CO in ppm and CO2 in percentage of concentration. The measurement was performed during the normal working day of the center, for the determination of the selection parameters of the fan as static pressure and extraction flow, the 6 steps described in the manual of ventilation of Soler and Palau of the year 2012 were followed. In the results it was determined that the ideal extractor fan to remove the flow present in the revision pits is the centrifugal extractor model Bs 700, which has the capacity to move flow rates of 675 m^3/h, as well as a maximum sound emission of 66 dB, this emission is considered for the daily exposure of 8 hours of work that the technicians have during their working day. With the calculated extraction flow rates and the concentration levels of CO and CO2, it was possible to determine the pressure increase in the pipes and the losses through accessories, for the different gases to be evacuated, the SOLID WORKS software was used. The automatic control system of the extractors was designed with photoelectric sensors and an automaton for the independent operation of the 4 extractors, thus ensuring that the gases go to the outside of the pits complying with a free discharge and ensuring that these gases do not re-circulate inward, guaranteeing the designed ventilation system.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;65T00537-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectSISTEMA DE VENTILACIÓNes_ES
dc.subjectREVISIÓN TÉCNICA VEHICULARes_ES
dc.subjectFOSAS DE REVISIÓNes_ES
dc.subjectSOLIDWORKS (SOFTWARE)es_ES
dc.titleAnálisis de la concentración de gases contaminantes en las fosas de revisión técnica vehicular de la Empresa Publica Mancomunada de Tránsito de Tungurahua (EPMTT) para el diseño e implementación de un sistema de ventilaciónes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMontúfar Paz, Paúl Alejandro-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES