dc.identifier.citationToapanta Bautista, Caterine Alexandra. (2023). Propuesta de implementación de un prototipo automatizado para el control de nivel de anolitos para la planta de pintura Ciauto Cia. Ltda. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21648-
dc.descriptionEl objetivo del trabajo de titulación es la propuesta de implementación de un prototipo automatizado para controlar el nivel de anolitos en la planta de pintura Ciauto. El prototipo consta de un tablero y una Interfaz Humano-Maquina (HMI) para el control de dos sistemas: agua desmineralizada (DI) y agua blanda. El primer sistema de agua DI permite el control de nivel de anolitos basado en la variable conductividad. Para la activación y puesta en marcha del sistema DI se considera dos modos: automático y manual. Consta de seis etapas: la primera, entrega voltaje necesario para alimentar los dispositivos de control y protección. La etapa de adquisición de señales, conformada por sensores de nivel y conductividad, permiten el encendido/apagado de la bomba y el cierre/apertura de las electroválvulas. Dichas señales son enviadas a la etapa de procesamiento cuyo principal elemento es un PLC-LX3V, encargado del envío y activación de señales de salida, en base al grafcet de control etapa-transición del proceso, consecutivamente activa la bomba que conforma la etapa de potencia, tal que se genere la circulación del agua. El control y visualización de los estados del sistema se realiza mediante un panel HMI-LEVI2070D, la etapa final permite la comunicación RS-485 entre la etapa de procesamiento y la HMI. El sistema de agua blanda, posee etapas similares a las del sistema DI. Como resultado, se determinó que la comunicación conservó un tiempo de respuesta de 1ms sin pérdida de datos y con respuestas coherentes a los mandos ejecutados desde la interfaz. Por ello, se concluye que la HMI posee un ambiente de diseño amigable con el operador para un eficiente control de nivel de conductividad en el tanque de anolito. Se recomienda implementar un sistema SCADA para un mejor control del proceso.es_ES
dc.description.abstractThis graduate research aimed to implement an automated prototype to control the level of anolytes in the Ciauto paint plant. The prototype consists of a panel and a Human-Machine Interface (HMI) to control two systems: demineralized water (DI) and soft water. The first DI water system allows for the control of analyte levels based on the conductivity variable. Two modes are considered for the activation and startup of the DI system: automatic and manual. It consists of six stages: the first one delivers the necessary voltage to power the control and protection devices. The signal acquisition stage, composed of level and conductivity sensors, enables the on/off control of the pump and the opening/closing of the solenoid valves. These signals are sent to the processing stage, whose main element is a PLC-LX3V responsible for sending and activating output signals based on the control process's stage-transition grafcet. Consequently, it activates the power stage pump, producing water circulation. The control and visualization of the system states are carried out through an HMI-LEV12070D panel. The final stage enables RS-485 communication between the processing stage and the HMI. The soft water system has stages similar to those of the DI system. As a result, it was determined that the communication maintained a response time of 1 ms without data loss and with coherent responses to commands executed from the interface. Therefore, it is concluded that the HMI provides a user-friendly design for efficient control of conductivity levels in the analyte tank. Implementing a SCADA system for better process control is recommended.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;108T0524-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectAUTOMATIZACIONes_ES
dc.subjectCONTROL DE NIVELes_ES
dc.subjectCOMUNICACIÓN RS-485es_ES
dc.subjectMODBUSes_ES
dc.subjectANOLITOes_ES
dc.titlePropuesta de implementación de un prototipo automatizado para el control de nivel de anolitos para la planta de pintura Ciauto Cia. Ltda.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalLozada Yánez, Pablo Eduardo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
108T0524.pdf3,58 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons