Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4508
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorEscobar, Sandra-
dc.contributor.authorPambabay Naranjo, María Fernanda-
dc.date.accessioned2016-03-03T19:39:47Z-
dc.date.available2016-03-03T19:39:47Z-
dc.date.issued2015-07-
dc.identifier.citationPambabay Naranjo, María Fernanda. (2015). Estudio microbiológico de las aguas termales Reina del Rosario de Cununyacu, parroquia Pilahuin, provincia Tungurahua. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4508-
dc.descriptionLas aguas termales Reina del Rosario de Cununyacu, no cuentan con un análisis microbiológico, para ello se realizó el estudio de la microbiota autóctona y alóctona, a través de la siembra en las Placas 3M™ Petrifilm y las pruebas de identificación microbiana. La microbiota autóctona fue analizada tomando muestras del ojo de agua, el resultado de este análisis fue el crecimiento de 1 UFC/ml perteneciente al género Bacillus, para determinar si existe o no microorganismos producto de una contaminación (alóctonos) se estudiaron muestras de agua tomadas de una de las piscinas donde se encontraron microorganismos de interés sanitario como: Escherichia coli 12 UFC/ml, Proteus vulgaris 1 UFC/ml, Providencia rettgeri 2 UFC/ml y 325 UFC/ml colonias del género Staphylococcus. Además de analizar la presencia de bacterias también se determinó que en el ojo de agua no existe presencia de mohos y levaduras, mientras que en una de las piscinas hubo crecimiento de estos dos tipos de microorganismos. Dentro del análisis microbiológico también se determinó el porcentaje de bacterias Gram (+) y de Gram (-) que habitan en estas termas resultando en mayor porcentaje las bacterias Gram (-) con un 66.67% y en menor cantidad las bacterias Gram (+) con un 33.33%. Para complementar el estudio se realizaron mediciones in situ del pH, temperatura, conductividad y solidos totales; las mediciones de estos parámetros se efectuó en el ojo de agua excepto de la temperatura que también fue tomada de la piscina de la cual se realizaría el estudio. Los resultados fueron: pH es 7.8, 40°C ,4519 µs /cm de conductividad y 2892.16 ppm se sólidos totales para el ojo de agua y 36.4°C para la piscina; con estos datos se concluye que se hace necesario adoptar medidas de control microbiológico e higiénico- sanitarias que brinden a sus usuarios bienestar y eviten patologías en la salud.es_ES
dc.description.abstractReina del Rosario de Cununyacu hot springs do not have a microbiological analysis, for this reason it was necessary to carry out a native and non-native microbiota study through the sowing in 3MTM Petrifilm plates as well as tests to identify microbes. The native microbiota was analyzed taking wáter samples resulting in the growing of 1 CFU/ml belonging to Bacillus, in order to determine the existence of non-native microorganisms causing the contamination, some wáter samples taken from the pool were analyzed, as a result some relevant microorganisms for sanitation such as: Escherichia coli 12 CFU/ml, Proteus vulgaris 1 CFU/ml, Providencia rettgery 2 CFU/ml, and colonies of Staphylococcus 325 CFU/ml were found. Apart from analyzing the presence of bacteria, it was also determined that the waterhole does not show the presence of molds and yeasts, while in one of the pools there was growth of these two types of microorganisms. Within the microbiological analysis the (+) and (-) Gram bacteria percentage living in these hot springs was also determined, this analysis resulted in a higher percentage of (-) Gram bacteria with 66.67% and a lower percentage of (+) Gram bacteria with 33. 33%. To complement the study some in situ measurements for pH, temperatura, conductivity, and total solids were carried out; the measurements of these parameters were carried out in the waterhole, except for the temperatura that was taken from the pool were the analysis was done. The results were: pH is 7.8, 40°C, 4519 µs /cm of conductivity and 2892.16 ppm of total solids for the waterhole and 36.4°C for pool; with this data it is concluded that it is necessary to adopt microbiologic and sanitary control measurements providing its user welfare and avoiding health pathologies.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazo.es_ES
dc.relation.ispartofseriesUDCTFC;56T00572-
dc.subjectAGUAS TERMALESes_ES
dc.subjectANÁLISIS MICROBIOLÓGICOes_ES
dc.subjectMICROBIOTA AUTÓCTONAes_ES
dc.subjectMICROBIOTA ALÓCTONAes_ES
dc.subjectUNIDADES FORMADORAS DE COLONIAS [UFC]es_ES
dc.subjectBIOQUÍMICAes_ES
dc.titleEstudio microbiológico de las aguas termales Reina del Rosario de Cununyacu, parroquia Pilahuin, provincia Tungurahua.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalMedina, Gerardo-
dc.contributor.miembrotribunalAndueza, Félix-
Aparece en las colecciones: Bioquímico/a y Farmacéutico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
56T00572 UDCTFC.pdf2,69 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.