dc.identifier.citationArias Viteri, José Eduardo. (2016). Propuesta de un modelo de confiabilidad basado en el contexto operativo del Bloque 57 Libertador para el sistema de reinyección de agua en la Empresa Petroamazonas EP. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4721-
dc.descriptionEste trabajo tiene como finalidad determinar la confiabilidad basado en un análisis real del contexto operativo, tomando en cuenta la disponibilidad intrínseca del sistema de reinyección de agua, asociados a la fiabilidad y mantenibilidad de los elementos que lo conforman, este estudio es realizado para el Bloque 57 Libertador, Provincia de Sucumbíos, Pacayacu [Parroquia]. La predicción de modos de fallo para evitar sus consecuencias es el objetivo principal de toda empresa, pues requiere aprender de la historia para mejorar el futuro al realizar análisis causa raíz y eliminar su recurrencia. La metodología utilizada fue la investigación de campo y registros históricos disponibles desde el año 2013, cuando se empiezan a registrar fallas en el software de gestión de mantenimiento “Máximo para Oil&Gas”, se utiliza técnicas de observación, revisión de: calidad de datos, reportes diarios de operación, diagramas de proceso, diagramas funcionales, métodos establecidos como análisis de bondad de ajuste para la distribución de probabilidad Exponencial y Weibull. Los resultados de fiabilidad para los 7 tipos de equipos que intervienen en el sistema de reinyección de agua se correlacionaron en base a las fallas por tipo de equipo en toda la población disponible para el bloque 57 Libertador, de esta manera se establece el diagrama de bloques de fiabilidad, con lo cual se logra predecir un valor de probabilidad de fallo en un tiempo estimado para cada sistema. Finalmente se puede proponer acciones para evitar que la fiabilidad del sistema sea inferior a 50% en un periodo de 3000 horas de funcionamiento continuo y la disponibilidad intrínseca de los sistemas sea inferior a 99.9% gracias a la intervención oportuna de mantenimiento, se recomienda implementar el modelo planteado en esta investigación para obtener mejores resultados.es_ES
dc.description.abstractThis research work has as purpose to determine the reliability of the water reinjection system in block 57 Liberator, Sucumbios Province, Pacayacu [Parish], which is based on a real analysis of the operational context, taking into account the intrinsic availability, associated with the reliability and maintainability of the elements that comprise it. The main objective of any company is predicting failure modes to prevent the consequences that this entails, since it requires learning of the previous history to make improvements in the future through o root cause analysis that would help eliminate its recurrence. The methodology used was the field research and historical records available since 2013, date in which it started to record failures in the “Maximum for Oil and Gas” maintenance and management software. It was also used observation techniques, revision of: data quality, operating daily reports, process diagrams, functional schematics and established methods such as analysis of goodness of-fit for the distribution Exponential probability and Weibull. The results of reliability for the 7 types of equipment involved in the water reinjection system were correlated based on failures by type of equipment throughout the available population to block 57 Liberator, this establishes the block diagram of reliability, with which it is possible to predict a value of probability of failure of an estimate for each system. Finally, it is possible to propose actions to prevent the reliability of the system from being lower than 50% in a period of 3000 hours of continuous operation, and the intrinsic availability of the systems from being lower than 99.9% thanks to the opportune maintenance intervention. It is recommended to implement the model proposed in this research for better results.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTIPEC;20T00708-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectCONFIABILIDAD DEL CONTEXTO OPERATIVOes_ES
dc.subjectFIABILIDAD Y MANTENIBILIDADes_ES
dc.subjectREGISTRO DE MODOS DE FALLOes_ES
dc.subjectMAXIMO OIL&GAS (SOFTWARE)es_ES
dc.subjectDISPONIBILIDAD INTRINSICAes_ES
dc.subjectDISTRIBUCIÓN DE PROBABILIDADes_ES
dc.subjectBLOQUE 57 LIBERTADORes_ES
dc.subjectSUCUMBIOS (PROVINCIA)es_ES
dc.titlePropuesta de un modelo de confiabilidad basado en el contexto operativo del Bloque 57 Libertador para el sistema de reinyección de agua en la Empresa Petroamazonas EPes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.contributor.miembrotribunalHaro Medina, Marco-
dc.contributor.miembrotribunalGuamán Mendoza, Ángel-
dc.rights.urihttps://creativecommons.org.//licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Maestrias: Modalidad Proyectos de Investigación y Desarrollo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
20T00708.pdf4,1 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons