Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4744
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorTerán, Carlos-
dc.contributor.authorRomero Jiménez, Jorge Eduardo-
dc.date.accessioned2016-05-19T14:37:52Z-
dc.date.available2016-05-19T14:37:52Z-
dc.date.issued2016-05-
dc.identifier.citationRomero Jiménez, Jorge Eduardo. (2016). Metodología para analizar las magnitudes operacionales: “Caso de estudio temperaturas” del sistema de gestión de energía XA/21 como herramienta de gestión operativa y de mantenimiento de los sistemas de la Central Hidroeléctrica Paute Molino. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4744-
dc.descriptionLa presente investigación tuvo como objetivo diseñar una metodología para el análisis de las magnitudes operacionales de temperatura del sistema de gestión de energía XA/21 en dos unidades de generación de la Central Hidroeléctrica Paute Molino, enfocados al monitoreo de condición como herramienta de vigilancia y protección para gestión de alarmas, gestión operativa y de mantenimiento. La información analizada fue tomada del software “Sistema de análisis y registro de operación y mantenimiento”, la cual es una herramienta de gestión operativa y administrativa de las Centrales de la Unidad de Negocio Hidropaute, para la interpretación estadística de los datos y la determinación de intervalos de tolerancia estadísticos se tomó como referencia la norma ISO 16269-6; la interpretación está enfocada a la adquisición de datos y análisis de acuerdo a la norma ISO 17359 de monitoreo de condición y diagnóstico de máquinas. Los resultados obtenidos son actividades de mantenimiento preventivo para los procesos de operación y mantenimiento que garantizan la conformidad de las mediciones y límites de control de alarmas apegados al contexto operacional. En conclusión se ha verificado que los límites de control de alarmas actuales no están acordes al contexto operacional actual, por lo que se recomienda la aplicación de la metodología propuesta para una adecuada gestión de alarmas, operativa y de mantenimiento.es_ES
dc.description.abstractThe objective of this research study was to design a methodology for the analysis of operational temperature levels for the power management system XA/21 in the two generation units of the Hydroelectric Power Station Paute Molino, focused on condition monitoring as a tool for the monitoring and protection for alarm management, operational management and maintenance. The information analyzed was taken from the software ´System analysis and operation and maintenance recording´ which is a tool for the operational and administrative management of the Power Stations of the company Hidropaute. The norm ISO 16269-6 was used as a reference for the statistical interpretation of data and the determination of statistical tolerance intervals; the interpretation is focused on data acquisition and analysis in accordance with norm ISO 17359 for condition monitoring and machine diagnostics. The results are preventive maintenance activities for operation and maintenance processes that ensure compliance with measurement and control limits for alarmas in the operational context. In conclusion it has been verified that the limits of current alarms are not commensurate with the current operational context, as a result the application, of the proposed methodology is recommended to ensure proper alarm management, operation and maintenance.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTIPEC;20T00716-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectSISTEMA DE GESTIÓN DE ENERGÍA (XA/21)es_ES
dc.subjectMONITOREO DE CONDICIÓNes_ES
dc.subjectGESTIÓN DE ALARMASes_ES
dc.subjectGESTIÓN OPERATIVAes_ES
dc.subjectGESTIÓN DE MANTENIMIENTOes_ES
dc.subjectCENTRAL HIDROELÉCTRICA PAUTE MOLINOes_ES
dc.subjectSISTEMA DE ANÁLISIS Y REGISTRO (SARDOM)es_ES
dc.titleMetodología para analizar las magnitudes operacionales: “Caso de estudio temperaturas” del sistema de gestión de energía XA/21 como herramienta de gestión operativa y de mantenimiento de los sistemas de la Central Hidroeléctrica Paute Molinoes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.contributor.miembrotribunalSexto, Luis Felipe-
dc.contributor.miembrotribunalAbad, Juan Carlos-
dc.rights.urihttps://creativecommons.org.//licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Maestrias: Modalidad Proyectos de Investigación y Desarrollo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
20T00716.pdf3,48 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons