dc.identifier.citationCunachi Aguilar, Marco Vinicio. (2016). Análisis y propuesta de mejora de confiabilidad de la plataforma de control PLC Controllogix 5000 de la Planta de Generación Eléctrica Wartsila Vasa 32 ubicada en Yuralpa Bloque 21. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/5118-
dc.descriptionEl análisis y propuesta de mejora de confiabilidad de la plataforma de control PLC (Controlador Lógico Programable) ControlLogix 5000 de la planta de generación eléctrica Wartsila Vasa 32 ubicada en Yuralpa Bloque 21, en el cantón Tena de la provincia del Napo; se obtienen las condiciones actuales del sistema, verificando que la confiabilidad es baja y necesita ser actualizada para mantener la planta de generación eléctrica en optima condición operacional. La arquitectura física del sistema de PLC, se lo convierte a diagramas de confiabilidad RBD (Diagramas de Bloques de Confiabilidad), e inicia desde las tarjetas de cada rack y resolviendo diagramas hasta llegar a la confiabilidad total del sistema. Para implementar los diagramas RBD es necesario llevar cada rack del sistema a bloques serie paralelo y se resuelve aplicando ecuaciones características. Se aplican las ecuaciones de redundancia hot standby para resolver el RBD del PLC CFA901 y de la configuración paralelo k-out-of-n que resulta de la necesidad operativa de la operación, de las unidades de generación en la planta. Los PLC son sistemas robustos y no presentan muchas fallas, por tanto, se utiliza el MTBF (Tiempo Medio entre Fallas), cuyos datos se utilizan para calcular la confiabilidad de cada componente. Según la evaluación de la plataforma de control PLC a los 13 años de funcionamiento, se concluye como resultado que la confiabilidad de 0.317288834 es baja, puesto que con el modelo probabilístico se evidencia que en cualquier componente esta disminuye con el tiempo, aunque no haya fallado durante el periodo de estudio; por lo tanto se recomienda cambiar los ítems obsoletos y las tarjetas 1794-IRT8 del rack CFE0_1 FLEX I/O A2 de toda la plataforma de control; y, en estas condiciones se calcula la confiabilidad del sistema total a los 14 años de funcionamiento, comprobando la mejora de la confiabilidad del sistema a 0.713425971.es_ES
dc.description.abstractAnalysis and proposal for improving reliability of the control platform PLC (Programmable Logic Controller) ControlLogix 5000 of the power plant Wartsila Vasa 32 located in Yuralpa Block 21, in the city of Tena Napo province; the current conditions of the system are obtained, verifying that the reliability is low and needs to be updated to maintain the power generation plant in optimum operating condition. The physical architecture of the system PLC, is turned into reliability diagrams RBD (Reliability Block Diagrams), and starts from cards in each rack and solving diagrams to reach the overall reliability of the system. To implement the RBD diagrams is necessary to take each rack from the system to serial parallel blocks and it is solved by applying characteristics equations. Hot stand by redundancy equations are applied to solve the RBD CFA901 PLC and the parallel configuration k-out-of-n resulting from the operational necessity for the operation of the generating units at the plant. The PLC systems are robust and do not have many flaws, therefore, the MTBF (Mean Time Between Failures), whose data are used to calculate the reliability of each component. According to the evaluation of the control platform PLC at 13 years of operation, it is concluded as a result that the reliability of 0.317288834 is low, since through the probabilistic model is evident that in any component decreases over time, even though it has not failed during the study period; therefore it is recommended to change the obsolete items and 1794-IRT8 rack cards CFE0_1 FLEX I/O A2 of the entire control platform; and in these conditions the reliability of the total system is calculated at 14 years of operating, checking improving system reliability to 0.713425971.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTIPEC;20T00752-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectPLATAFORMA DE CONTROLes_ES
dc.subjectCONTROLADOR LÓGICO PROGRAMABLE (PLC)es_ES
dc.subjectTIEMPO MEDIO ENTRE FALLAS (MTBF)es_ES
dc.subjectYURALPA BLOQUE 21es_ES
dc.subjectTENA (CANTÓN)es_ES
dc.subjectNAPO (PROVINCIA)es_ES
dc.titleAnálisis y propuesta de mejora de confiabilidad de la plataforma de control PLC Controllogix 5000 de la Planta de Generación Eléctrica Wartsila Vasa 32 ubicada en Yuralpa Bloque 21es_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.contributor.miembrotribunalFreire Miranda, Jorge-
dc.contributor.miembrotribunalVallejo Vizuete, Henry Ernesto-
dc.rights.urihttps://creativecommons.org.//licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Maestrias: Modalidad Proyectos de Investigación y Desarrollo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
20T00752.pdf4,29 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons